1. Bubuka
The ATTEN ST-1202 is a high-performance dual-channel smoke purifier and solder filter designed to effectively remove harmful fumes and particles generated during soldering and other industrial processes. Featuring an integrated metal frame, a powerful DC brushless fan, and a multi-layer filtration system, it ensures a cleaner and safer working environment. This manual provides essential information for the proper setup, operation, and maintenance of your ST-1202 unit.
2. Fitur konci
- Integrated design with durable metal frame.
- Equipped with directional wheels and rubber feet for stability and mobility.
- High-power DC brushless fan for efficient fume extraction and low noise operation.
- Large LCD display screen for easy monitoring.
- Advanced 3-layer filtration system with a purification rate of up to 99.97% for 0.3 micron particles.
- Quick and easy replacement of individual filter layers.
- Filter blockage alarm for timely maintenance alerts.
- Supports two independent working positions with flexible extraction arms.
- Adjustable air volume and flow control.
- Wind wheel made of special alloy to prevent corrosion.
3. Produk Langkungview jeung Komponén
The ATTEN ST-1202 unit consists of the main body, two flexible extraction arms with nozzles, a control panel, and a multi-layer filter system. The main body houses the fan, motor, and filter compartments. The control panel allows for power control and air volume adjustment.

Gambar 1: Hareupeun view of the ST-1202 with dual extraction arms.

Gambar 2: Sisi view of the ST-1202 with extended arms.

Gambar 3: Tukangeun view of the ST-1202.
Video 1: Demonstration of the ATTEN ST-1202's flexible extraction arms and overall design.
4. Parentah Setup
- Ngabongkar bungkusan: Carefully remove the smoke purifier from its packaging. Retain all packaging materials for future transport or storage.
- panempatan: Place the unit on a stable, level surface. Ensure there is adequate space around the unit for proper airflow and maintenance access.
- Pamasangan Arm: Insert the flexible extraction arms into the designated ports on the top of the unit. Ensure they are securely fitted.
- Nozzle adjustment: Position the nozzles of the extraction arms close to the source of fumes (e.g., soldering point) for optimal capture. The flexible pipes can be adjusted to various angles and positions.
- Sambungan Daya: Connect the power cord to the unit and then to a suitable 220V EU PLUG power outlet.
- Initial Filter Check: Before first use, ensure all three filter layers (Pre-filter, Middle filter, Main filter) are correctly installed in their respective compartments. Refer to the 'Maintenance' section for filter orientation.
5. Parentah Operasi
- Daya Hurung: Press the power button on the control panel to turn on the unit. The LCD screen will illuminate.
- Saluyukeun Volume Udara: Use the control knob on the panel to adjust the air volume and suction power according to your needs. Start with a lower setting and increase as required for effective fume extraction.
- Posisi: During operation, ensure the extraction nozzles are positioned as close as possible to the fume source to maximize capture efficiency.
- Ngawaskeun: Observe the LCD display for any alerts, such as a filter blockage alarm, which indicates that a filter needs inspection or replacement.
- Pareum listrik: Saatos dianggo, pencét tombol daya pikeun mareuman unit.
6. Pangropéa
Regular maintenance is crucial for the optimal performance and longevity of your ATTEN ST-1202 smoke purifier. Pay close attention to filter replacement schedules.
6.1 Sistem Filter Leuwihview
The unit utilizes a triple-layer filtration system:
- Pra-filter: Nangkep partikel anu langkung ageung.
- Middle filter: Nangkep partikel ukuran sedeng.
- saringan utama: Captures fine particles and absorbs harmful gases.

Figure 4: Filter layers and recommended replacement cycles.
6.2 Filter ngagantian
The sequence of filters must be subject to the right diagram. Disorganization is strictly forbidden. The relatively dense side of the pre-filter faces down.
Suggested Replacement Cycles:
- Pra-filter: Unggal 10-15 poé
- Middle filter: Unggal 3-6 bulan
- saringan utama: Unggal 6-9 bulan
Remark: The actual replacement cycles of filters shall be subject to the pollution levels of different sites and usage frequency. The unit's filter blockage alarm will also indicate when a filter needs attention.
6.3 beberesih
Regularly wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off and unplugged before cleaning.
7. Spésifikasi
| Item No | ST-1101 | ST-1202 |
|---|---|---|
| Voltage | 230V | 230V |
| Kakuatan | 160W | 180W |
| Posisi gawé | 1 | 2 |
| Tiupan hawa | 240m³/H (±10%) | 150m³/H*2 (±10%) |
| Filtration efficiency (0.3 micron) | 99.97% | 99.97% |
| Diménsi | 465 x 250 x 480 mm | 465 x 250 x 480 mm |
| NW | 17 kg | 18.2 kg |
8. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Unit teu hurung | No power supply; Power cord loose; Unit fault | Check power connection and outlet; Ensure power cord is securely plugged in; Contact customer support if problem persists. |
| kakuatan nyeuseup low | Filters are clogged; Air volume setting too low; Obstruction in arms/nozzles | Check and replace filters as needed; Increase air volume setting; Clear any obstructions from the arms or nozzles. |
| Filter blockage alarm activates | One or more filters are saturated/clogged | Inspect and replace the indicated filter(s) immediately. |
| Noise mahiwal salila operasi | Foreign object in fan; Fan malfunction | Power off and unplug the unit. Carefully inspect for foreign objects. If noise persists, contact customer support. |
9. Garansi jeung Rojongan
For warranty information, technical support, or service inquiries, please refer to the documentation provided at the time of purchase or contact your authorized ATTEN dealer. Keep your purchase receipt as proof of purchase.