1. Bubuka
This manual describes the assembly, installation, operation, and troubleshooting of the Anern Hybrid Solar Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.
1.1 Produk Leuwihview
The Anern Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings and easy operation.


1.2 Fitur
- Murni inverter gelombang sinus
- Input Configurable voltage rentang pikeun panerapan imah jeung komputer pribadi via setting LCD
- Batré anu tiasa dikonfigurasi ngecas ayeuna dumasar kana aplikasi via setting LCD
- Prioritas AC / Solar Charger anu tiasa dikonfigurasi ngalangkungan setting LCD
- Cocog jeung mains voltage atawa kakuatan generator
- Otomatis balikan deui nalika AC pulih
- Overload, leuwih suhu, sareng panyalindungan sirkuit pondok
- Desain carjer batré pinter pikeun kinerja batré anu dioptimalkeun
- Fungsi mimiti tiis
1.3 Arsitéktur Sistim Dasar
The inverter/charger can be integrated into a complete running system that includes a generator or utility power source and PV modules. It can power various home and office appliances, including motor-type appliances up to 1.5HP.


2. Parentah Kasalametan
PERHATOSAN: Bab ieu ngandung parentah kaamanan sareng operasi anu penting. Baca jeung simpen manual ieu pikeun rujukan ka hareup.
- Sateuacan nganggo unit, baca sadayana petunjuk sareng tanda peringatan dina unit, batré, sareng sadaya bagian anu luyu dina manual ieu.
- PERHATOSAN: Pikeun ngurangan résiko tatu, ngecas ukur batré rechargeable tipe asam lead siklus jero. Batré tipe séjén bisa peupeus, ngabalukarkeun tatu jeung karuksakan pribadi.
- Ulah ngabongkar unit. Bawa ka pusat layanan anu mumpuni nalika diperyogikeun atanapi diperyogikeun. Majelis ulang anu salah tiasa nyababkeun résiko shock listrik atanapi seuneu.
- Pikeun ngirangan résiko kasetrum listrik, pegatkeun sambungan kabel sateuacan nyobian pangropéa atanapi beberesih. Pareuman unit moal ngirangan résiko ieu.
- PERHATOSAN: Ngan tanaga mumpuni anu tiasa masang alat ieu nganggo batré.
- MOAL ngeusi batre beku.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Janten ati-ati pisan nalika damel sareng alat logam dina atanapi sakitar batré. Résiko poténsial aya pikeun leupaskeun alat pikeun narik atanapi batré sirkuit pondok atanapi bagian listrik sanés sareng tiasa nyababkeun ngabeledug.
- Please strictly follow installation procedures when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
- PETUNJUK GROUNDING: Inverter / carjer ieu kedah dihubungkeun ka sistem kabel grounded permanén. Pastikeun pikeun sasuai jeung sarat jeung peraturan lokal pikeun masang inverter ieu.
- MOAL cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Awas: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, send this inverter/charger back to local dealer or service center for maintenance.
Inverter Use Notice:
- The starting power of inductive load electrical appliances shall be at least three times the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
- Please connect the circuit correctly according to the instructions, and install switches for each circuit.
- Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains, and load switches.
- Shutdown sequence: turn off the switches of load, PV, and mains, turn off the inverter, and finally turn off the battery.
3. Setélan
3.1 Ngabongkar sareng Inspeksi
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the unit and a user manual.
3.2 Persiapan
Before connecting all wirings, take off the bottom cover by removing two screws.
3.3 Pasang Unit
Pertimbangkeun poin-poin ieu sateuacan milih dimana dipasang:
- Ulah pasang inverter dina bahan konstruksi kaduruk.
- Pasang dina permukaan padet.
- Pasang inverter ieu dina tingkat panon pikeun ngamungkinkeun tampilan LCD dibaca sepanjang waktos.
- Pikeun sirkulasi hawa ditangtoskeun pikeun dissipate panas, ngidinan clearance of approx. 20 cm ka sisi sareng kira-kira. 50 cm di luhur sareng di handap unit.
- Suhu ambient kedah antara 0 ° C sareng 55 ° C pikeun mastikeun operasi optimal.
- Posisi pamasangan anu disarankeun kedah dipasang kana témbok sacara vertikal.
- Be sure to keep other objects and surfaces clear to guarantee sufficient heat dissipation and space for removing wires.
Cocog pikeun dipasang dina beton atawa permukaan non-combustible séjén wungkul.
Install the unit by screwing two screws. It's recommended to use M4 or M5 screws.

3.4 Sambungan Batré
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. All wiring must be performed by a qualified personnel.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
| Modél | Ukuran Kawat | Kabel (mm²) | Nilai torsi (max) |
|---|---|---|---|
| 2.0KW / 12V | 1 x 6AWG | 14 | 5 Nm |
| 3.2KW / 24V | 1 x 6AWG | 14 | 5 Nm |
Follow these steps to implement battery connection:
- Leupaskeun leungeun baju insulasi 18 mm pikeun konduktor positif jeung negatif.
- Nyarankeun nempatkeun ferrules bootlace dina tungtung kabel positif sareng negatif kalayan alat crimping anu leres.
- Connect all battery packs as shown in the diagram.
- Insert the battery wires flatly into battery connectors of the inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity is correct at both the battery and the inverter/charger. Recommended tool: #2 Pozi Screwdriver.

PERHATOSAN: Bahaya Setrum! Pamasangan kedah dilakukeun kalayan ati-ati kusabab voltase batré anu luhurtage dina runtuyan.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 Input AC / Sambungan Kaluaran
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 20A for 2.0KW and 30A for 3.2KW.
Attention: After 90s of mains power connection to the inverter, the machine is connected to the mains and starts to work.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
PERHATOSAN: Kabéh wiring kudu dipigawé ku tanaga mumpuni.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Modél | Gauge | Nilai torsi |
|---|---|---|
| 2.0KW / 12V | 12 AWG | 2 Nm |
| 3.2KW / 24V | 12 AWG | 2 Nm |
Turutan léngkah ieu pikeun nerapkeun sambungan input/output AC:
- Saméméh nyieun sambungan input/output AC, pastikeun pikeun muka pelindung DC atawa disconnector munggaran.
- Leupaskeun leungeun baju insulasi 10mm pikeun genep konduktor. Jeung shorten fase L jeung konduktor nétral N 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (⚠) first.
- ⚠ → Ground (yellow-green)
- L → GARIS (coklat atawa hideung)
- N → Nétral (biru)
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws.
- L → GARIS (coklat atawa hideung)
- N → Nétral (biru)
PERHATOSAN: Pastikeun yén sumber listrik AC dipegatkeun saencan nyobian ngahubungkeun kabel ka unit.
3.6 Sambungan PV
PERHATOSAN: Sateuacan nyambungkeun ka modul PV, mangga install misah a DC circuit breaker antara inverter na modul PV.
WARNING: It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Modél | Ukuran Kawat | Nilai torsi (max) |
|---|---|---|
| 2.0KW / 12V | 1x10AWG | 2 Nm |
| 3.2KW / 24V | 1x10AWG | 2 Nm |
Pamilihan Modul PV
When selecting proper PV modules, be sure to consider these parameters:
- Buka sirkuit Voltage (Voc) modul PV teu kudu ngaleuwihan max. PV Asép Sunandar Sunarya kabuka circuit voltage tina inverter.
- Buka sirkuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| MODÉL INVERTER | 2.0KW | 3.2KW |
|---|---|---|
| Max. PV Array Buka Circuit Voltage | 150vdc | |
| PV Array MPPT Voltage Rentang | 20 ~ 150Vdc | 30 ~ 150Vdc |
Taking a 250Wp PV module as an example, the recommended module configurations are:
| Spésifikasi Panel Surya. (rujukan) | SOLAR INPUT (Max in serial: 4pcs) | Q'ty of panels | Total kakuatan input |
|---|---|---|---|
| 250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60 | 2 PCS dina serial | 2 buah | 500W |
| 3 PCS dina serial | 3 buah | 750W | |
| 4 PCS dina serial | 4 buah | 1000W |
PV Module Kawat Connection
Turutan léngkah ieu pikeun nerapkeun sambungan modul PV:
- Leupaskeun leungeun baju insulasi 10 mm pikeun konduktor positif jeung negatif.
- Nyarankeun nempatkeun ferrules bootlace dina tungtung kabel positif sareng negatif kalayan alat crimping anu leres.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
3.7 Majelis ahir
After connecting all wirings, put the bottom cover back by screwing four screws.
4. Parentah Operasi
4.1 Daya ON / OFF
Once all wiring is properly connected, and the machine is connected to the battery, press the power switch (located on the side of the machine) to start the unit. The machine will not start if the mains or photovoltaic power is connected but the switch is off.
4.2 Operasi jeung Panel Témbongkeun
The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.


Indikator LED
| Indikator LED | Warna | Talatah |
|---|---|---|
| AC/INV | Héjo | Padet Hurung: Kaluaran didamel ku utilitas dina modeu Line. Kedip-kedip: Kaluaran didamel ku batré atanapi PV dina modeu batré. |
| CHG | Héjo | Padet Hurung: Batré dicas pinuh. Kedip-kedip: Batré keur dieusi. |
| SALAH | Beureum | Padet On: Sesar lumangsung dina inverter nu. Kedip-kedip: kaayaan Awas lumangsung dina inverter nu. |
Tombol Fungsi
| Tombol Fungsi | Katerangan |
|---|---|
| ESC | Pikeun kaluar tina mode setelan |
| UP | Pikeun pindah ka pilihan saméméhna |
| TURUN | Pikeun pindah ka pilihan salajengna |
| Asupkeun | Pikeun ngonfirmasi pilihan dina mode setelan atawa asupkeun mode setelan |
4.3 Setélan LCD
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" to select setting programs. Then, press "ENTER" to confirm the selection or ESC to exit.
Setting Programs Overview
The manual provides detailed programs for configuring various aspects of the inverter's operation, including:
- Program 00: Exit setting mode (Escape, One-button restore setting options)
- Program 01: Output source priority (Utility first, Solar first, SBU priority, MKS priority)
- Program 02: Maximum charging current (10A to 140A options)
- Program 03: AC input voltage rentang (Appliances, UPS)
- Program 05: Battery type (AGM, Flooded, User-Defined)
- Program 06: Auto restart when overload occurs (Restart disable, Restart enable)
- Program 07: Auto restart when over temperature occurs (Restart disable, Restart enable)
- Program 09: Output frequency (50Hz, 60Hz)
- Program 10: Output voltage (220V, 230V, 240V)
- Program 11: Maximum utility charging current (2A to 80A options)
- Program 12: Setting voltage nunjuk deui ka sumber utiliti (for MKS/SBU priority, 2.0KW/12V default 11.5V, 3.2KW/24V default 23V)
- Program 13: Setting voltage point back to battery mode (for MKS/SBU priority, 2.0KW/12V default 13.5V, 3.2KW/24V default 27V)
- Program 14: Maximum battery discharge current (10A to 120A options)
- Program 16: Charger source priority (Solar first, Solar and Utility, Only Solar)
- Program 18: Alarm control (Alarm on, Alarm off)
- Program 19: Auto return to default display screen (Return to default, Stay at latest screen)
- Program 20: Backlight control (Backlight on, Backlight off)
- Program 22: Beeps while primary source is interrupted (Alarm on, Alarm off)
- Program 23: Overload bypass (Bypass disable, Bypass enable)
- Program 25: Record fault code (Record enable, Record disable)
- Program 26: Bulk charging voltage (CV voltage) (2.0KW/12V default 14.1V, 3.2KW/24V default 28.2V)
- Program 27: Floating charging voltage (2.0KW/12V default 13.5V, 3.2KW/24V default 27V)
- Program 29: Low DC cut-off voltage (2.0KW/12V default 10.0V, 3.2KW/24V default 20.0V)
- Program 30: Battery equalization (Battery equalization, Battery equalization disable)
- Program 31: Battery equalization voltage (2.0KW/12V default 14.6V, 3.2KW/24V default 29.2V)
- Program 33: Battery equalized time (60min default)
- Program 34: Battery equalized timeout (120min default)
- Program 35: Equalization interval (30 days default)
- Program 36: Equalization activated immediately (Enable, Disable)
- Program 39: RGB control (Backlight on, RGB off)
- Programs 81-85: Time setting (Year, Month, Day, Hour, Minute)
- Program 86: Clear Energy (Enable, Disable)
- Programs 87-90: Timer settings for AC charging (Start Hour/Minute, Deadline Hour/Minute)
4.4 Setélan tampilan
The LCD display information can be cycled by pressing the "Up" or "DOWN" keys. Selectable information includes: input voltage / kaluaran voltage, frékuénsi input, PV voltage, PV input current, PV input power, charging current, charging power, battery voltage, frékuénsi kaluaran, persen bebantage, load in VA, load in Watt, DC discharging current, Daily power generation, Monthly power generation, Gross generation, Date, Time, and main CPU Version.
4.5 Operasi Pedaran Mode
The inverter operates in various modes, each with specific behaviors and display indications:
- Standby mode / Power saving mode: The inverter is not outputting power, but can charge batteries. In power saving mode, output is off if the connected load is very low.
- Modeu Jalur: The unit provides output power from the mains and charges the battery. If 'solar first' is selected and solar energy is insufficient, solar and utility will power loads and charge the battery.
- Mode batré: The unit provides output power from the battery and PV power. PV energy will supply power to loads and charge the battery.
- Mode kasalahan: Errors caused by internal circuit issues or external reasons like over temperature or output short circuit. PV energy and utility can still charge batteries.
5. Pangropéa
5.1 Batre Equalization Katerangan
The equalization function reverses the buildup of negative chemical effects like stratification and helps remove sulfate crystals from battery plates. This process is crucial for maintaining battery capacity and is recommended periodically.
Kumaha Larapkeun Fungsi Equalization
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function by either of these methods:
- Nyetél interval ékualisasi dina program 35.
- Ékualisasi aktip langsung dina program 36.
Iraha Sasaruaan
Dina ngambang stage, when the setting equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.
Equalize Charging Time and Timeout
Dina Equalize stage, the controller supplies power to charge the battery until the battery voltage reaches the equalization voltage. Constant-voltage regulation maintains this voltage until the set battery equalized time is reached. If the battery voltage does not rise to the equalization point within the equalized time, the charge controller will extend the time. If the voltage is still low after the timeout, the charge controller will stop equalization and return to the float stage.
5.2 Clearance and Maintenance for Anti-Dust Kit (Optional)
Every inverter is installed with an anti-dust kit from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust internal temperature. This kit also keeps dust out of your inverter and increases product reliability in harsh environments.
- Remove screws as shown in the manual.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
PERHATOSAN: Kit anti debu kedah dibersihkeun tina lebu unggal sasih.
6. Cara ngungkulan
6.1 Kode Rujukan Sesar
| Kode Kasalahan | Acara Kasalahan | Ikon hurung |
|---|---|---|
| 01 | Kipas dikonci nalika inverter pareum. | 01 |
| 02 | Leuwih suhu | 02 |
| 03 | Batré voltage luhur teuing | 03 |
| 04 | Batré voltage handap teuing | 04 |
| 05 | Output circuited pondok atawa leuwih suhu dideteksi ku komponén converter internal. | 05 |
| 06 | Kaluaran voltage luhur teuing. | 06 |
| 07 | Overload waktos kaluar | 07 |
| 08 | Beus voltage luhur teuing | 08 |
| 09 | Mimitian lemes beus gagal | 09 |
| 51 | Leuwih arus atawa surge | 51 |
| 52 | Beus voltage handap teuing | 52 |
| 53 | Inverter lemes mimiti gagal | 53 |
| 55 | Leuwih DC voltage dina kaluaran AC | 55 |
| 57 | Sénsor ayeuna gagal | 57 |
| 58 | Kaluaran voltage handap teuing | 58 |
| 59 | PV voltage geus leuwih watesan | 59 |
6.2 Indikator Awas
| Kode Peringatan | Acara Perhatosan | Alarm karungu | Ikon kedip-kedip |
|---|---|---|---|
| 01 | Kipas dikonci nalika inverter hurung. | Bip tilu kali unggal detik | 01 |
| 04 | batré lemah | Bip sakali unggal detik | 04 |
| 07 | Overload | Bip sakali unggal 0.5 detik | 07 |
| 10 | kakuatan kaluaran derating | Bip dua kali unggal 3 detik | 10 |
| 15 | Énergi PV rendah. | Bip dua kali unggal 3 detik | 15 |
| 16 | PV voltage luhur | Bip dua kali unggal 3 detik | 16 |
| E9 | Equalization batré | Euweuh | E9 |
6.3 Patarosan anu Sering Ditaroskeun (FAQ)
- Q: Whether to start with battery? A: Henteu.
- Q: Whether it can directly supply power to the load? A: Enya.
- Q: Whether it can be connected to the grid? A: PV gives priority to power supply to the load, and extra to charge the battery. More can be integrated into the grid (needs to be based on local government policies). Note: 1600W and 3000W models cannot send remaining power to the grid.
- Q: How many solar panels need to be connected? A: To start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, with a maximum not exceeding 500V. For PRO-3.6KW/PLUS-6.2KW, the power of the solar panel should not exceed 6.2KW/6.5KW. For example, 10 pcs of 250W 30V solar panels connected in series.
- Q: Can inverters be connected in series or parallel? A: Henteu.
- Q: Is this an on-grid tied inverter? Can it be output to utility? A: Yes. It is a hybrid inverter that can be both off-grid and on-grid connected.
- Q: Does the inverter have to be connected to the battery? A: Can be connected with or without battery, but without the battery, the voltage of the solar panel should exceed 360Vdc.
- Q: What types of batteries can be used? A: Lead-acid batteries, gel batteries, Lithium Iron Phosphate (LiFePo4), and lithium batteries can be used. A 24V battery is for the 3.6KW model, and a 48V battery for the 6.2KW model. The battery capacity cannot be less than 100AH.
- Q: Can it be used in air conditioners, water pumps, and wind turbines? A: It can be used in air conditioners, but not in water pumps and wind turbines.
- Q: Is it a high frequency inverter or a low frequency inverter? A: High frequency.
- Q: Can the utility be used to power the inverter when there is no sun? A: Enya.
- Q: How to choose the power of the inverter according to the household appliances? A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter should be at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
- Q: Is it possible to use PV, battery, grid supply at the same time? A: Yes. In the default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
7. Spésifikasi
7.1 Sipat produk
| Ngaran atribut | Niley Atribut |
|---|---|
| Ngaran Brand | ANERN |
| Nomer modél | SCI-ECO2000&3200 |
| Kaluaran Ayeuna | 80A |
| Daya Kaluaran | 1 - 200 KW |
| Ukuran | 390 * 270 * 100 mm |
| Tipe Kaluaran | BUJANG |
| Beurat | 4.4 Kg / 5.4 Kg |
| Frékuénsi Kaluaran | 50Hz/60Hz |
| Nyaeta Alat Smart | Sumuhun |
| Asalna | Daratan Cina |
| Sertifikasi | CE |
| Masukan Voltage | 12V / 24V |
| AC Masukan Voltage | 230VAC |
| Tipe | DC/DC Converters, DC/AC Inverters |
| Efficiency (Peak) PV to Inverter | 98% |
| Ngaran produk | solar inverter 24V |
| Kakuatan dipeunteun | 2000KVA/1600W&3200KVA/3000W |
| Ngecas Maksimum Ayeuna | 80A |
| Arus AC Maksimum Ayeuna | 60A |
| Bentuk gelombang | Gelombang sinus murni |
| panganteur komunikasi | Wifi |
| Kimia anu prihatin tinggi | Euweuh |
7.2 Spésifikasi Mode Line
| MODÉL INVERTER | 2.0KW / 12V | 3.2KW / 24V |
|---|---|---|
| Masukan Voltage Gelombang | Sinusoid (utilitas atanapi generator) | |
| Nominal Masukan Voltage | 230Vac | |
| Leungitna Voltage | 170Vac±10V (UPS); 90Vac±10V (Home Appliances) | |
| Low Loss Balik deui Voltage | 180Vac±10V (UPS); 100Vac±10V (Home Appliances) | |
| High Loss Voltage | 280Vac±10V | |
| High Loss Balik deui Voltage | 270Vac±10V | |
| Max AC Input Voltage | 300Vac | |
| Frékuénsi Input nominal | 50Hz / 60Hz (Deteksi otomatis) | |
| Frékuénsi Leungitna Low | 40±1Hz | |
| Frékuénsi Balik Loss Low | 42±1Hz | |
| Frékuénsi Leungitna Tinggi | 65±1Hz | |
| Frékuénsi Balik Loss Tinggi | 63±1Hz | |
| Kaluaran Short Circuit Protection | Circuit breaker | |
| Efisiensi (Mode Garis) | > 95% (Rated R beban, batré pinuh dicas) | |
| Waktu Mindahkeun | 10 ms | |
7.3 Spésifikasi Mode Inverter
| MODÉL INVERTER | 2.0KW / 12V | 3.2KW / 24V |
|---|---|---|
| Dipasang Output Kakuatan | 2.0KVA / 2.0KW | 3.2KVA / 3.2KW |
| Kaluaran Voltage Gelombang | Galura murni | |
| Kaluaran Voltage Perda | 230Vac±5% | |
| Frékuénsi Kaluaran | 50Hz | |
| Efisiensi Puncak | 92% | |
| Overload Protection | 3s@ 150% load; 5s@ 100% ~ 150% load | |
| Kapasitas surge | 2 * kakuatan dipeunteun pikeun 1 detik | |
| Nominal DC Input Voltage | 12vdc | 24vdc |
| Tiis Mimitian Voltage | 11.5vdc | 23.0vdc |
| Low DC Perhatosan Voltage @ beban < 50% | 11.25vdc | 22.5vdc |
| Low DC Perhatosan Voltage @ load ≥ 50% | 11.0vdc | 22vdc |
| Low DC Peringatan Balik Voltage @ beban < 50% | 11.75vdc | 23.5vdc |
| Low DC Peringatan Balik Voltage @ load ≥ 50% | 11.5vdc | 23vdc |
| Low DC Cut-off Voltage @ beban < 50% | 10.75vdc | 21.5vdc |
| Low DC Cut-off Voltage @ load ≥ 50% | 10.5vdc | 21vdc |
| High DC Pamulihan Voltage | 15.5vdc | 31vdc |
| Tinggi DC Cut-off Voltage | 16.0vdc | 32vdc |
| Taya Konsumsi Daya Beban | <38w | |
7.4 Ngecas Mode spésifikasi
Utiliti Ngecas Mode
| MODÉL INVERTER | 2.0KW / 12V | 3.2KW / 24V |
|---|---|---|
| Algoritma ngecas | 3-Léngkah | |
| Arus Ngecas AC (Max) | 80Amp (@Vl/p=230Vac) | 80Amp (@Vl/p=230Vac) |
| Bulk Ngecas Voltage Flooded Battery | 14.6 | 29.2 |
| Bulk Ngecas Voltage AGM / Gel Battery | 14.1 | 28.2 |
| Ngambang Ngecas Voltage | 13.5vdc | 27vdc |
MPPT Solar Ngecas Mode
| MODÉL INVERTER | 2.0KW / 12V | 3.2KW / 24V |
|---|---|---|
| Max. Kakuatan Array PV | 2000W | 3200W |
| PV Array MPPT Voltage Rentang | 20 ~ 150Vdc | 30 ~ 150Vdc |
| Max. PV Array Buka Circuit Voltage | 150vdc | |
| Max solar ngecas ayeuna | 60Amp | |
| Max (AC + Solar) Ngecas ayeuna | 140Amp | |
7.5 Spésifikasi Umum
| MODÉL INVERTER | 2.0KW / 12V | 3.2KW / 24V |
|---|---|---|
| Sertifikasi Kasalametan | CE | |
| Kisaran Suhu Operasi | -10°C nepi ka 50°C | |
| Suhu Panyimpenan | -15°C ~ 60°C | |
| Kalembaban | 5% nepi ka 95% Kalembaban Relatif (Non-condensing) | |
| Diménsi (D * W * H), mm | 415X290X111 | |
| Beurat Bersih, kg | 7.2 | 7.3 |
8. Tips pamaké
- Inductive Load Sizing: When connecting appliances with inductive loads (e.g., refrigerators, washing machines, air conditioners), ensure the inverter's power rating is at least three times the total power of these appliances to prevent startup issues or damage.
- Operasi kirang batré: The inverter can operate without a battery, but the solar panel voltage must exceed 360Vdc for proper function.
- Panel Surya Voltage: For normal inverter startup, aim for a solar panel voltage between 300V-400V, not exceeding 500V.
- Integrasi Sistim: This is a hybrid inverter, capable of both off-grid and on-grid connections. It prioritizes PV power, supplementing with battery and utility power when solar input is insufficient.
- Pangropéa biasa: Clean the anti-dust kit monthly to ensure optimal performance and longevity of the inverter.
9. Garansi jeung Rojongan
For warranty information, technical support, or service inquiries, please contact your local dealer or the manufacturer directly. Refer to the official product websitus wéb atanapi dokuméntasi pameseran anjeun kanggo detil kontak khusus sareng syarat garansi.
A user manual in PDF format is available for download from the manufacturer's website for detailed instructions and diagrams: Anern Hybrid Solar Inverter User Manual (PDF)