Coolmay QM3G-100FH-44MT

Coolmay 10.1 Inch HMI PLC Touch Screen QM3G-100FH-44MT User Manual

Model: QM3G-100FH-44MT | Brand: Coolmay

1. Bubuka

This manual provides detailed instructions for the Coolmay QM3G-100FH-44MT HMI PLC All-in-One machine. This device integrates a Human Machine Interface (HMI) and a Programmable Logic Controller (PLC) into a single unit, designed for industrial automation applications. It offers a 10.1-inch touch screen for user interaction and a robust PLC for control logic.

The QM3G-100FH-44MT model features 24 digital inputs (DI) and 20 digital outputs (DO) with transistor outputs. It includes 1 RS232 and 1 RS485 communication port, 4 high-speed pulse outputs (100KHz, Y0-Y3), and 4 high-speed pulse outputs (10KHz, Y4-Y7). Optional analog input and output functions are available and must be purchased separately.

Hareupeun view of Coolmay QM3G-100FH HMI PLC with a sample interface displaying digital values and controls.

Gambar 1: Hareupeun view of the QM3G-100FH HMI PLC with a sampantarmuka éta.

Tukangeun view of Coolmay QM3G-100FH HMI PLC showing various communication ports (USB, Ethernet, RS232, RS485) and terminal blocks for I/O and power.

Gambar 2: Tukangeun view of the QM3G-100FH HMI PLC, highlighting communication ports and I/O terminals.

2. Fitur Produk

3. Spésifikasi

Spésifikasi Umum (QM3G-100FH)

ParameterNilai
Layar PintonanLayar LCD TFT 10.1"
Resolusi (piksel)1024*600
Diménsi275 * 194 * 36 mm
Ukuran potongan262 * 180 mm
Ukuran tampilan222 * 125 mm
Caang300cd/m²
Babandingan kontras400:1
Lampu tukangLED
Warna tampilan65536 warna leres
Jenis toélPanel résistif 4-kawat
Akurasi toélPanjangna (X) ± 1.5% Lebarna (Y) ± 1.5%
ROM (Flash)NOR Flash 16MB
Ram64 MB
CPU408MHz
Alat USBUSB 2.0 (Tipe-C)
port serialRS-232

PLC Specifications (QM3G-100FH-44MT)

ParameterNilai
Tipe I/OTransistor output: low level NPN, COM connected to negative; Relay output: normally open dry contact. Input: passive NPN, common terminal isolation.
DO TypeRelay MR or MOS Relay output max load 5A/ MOS output max load 2A. Relay MR or transistor MT. Y0-Y3 are MOS or mixed (MR/MT) relay output max load 5A/ transistor output max load 500mA.
cacah-speed tinggi6 single-phase 60KHz or 2 AB (Z) phase 60KHz + 1 AB phase 10KHz
Pulsa kecepatan tinggi8 channels: Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. high-speed counting + high-speed pulse ≤480KHz
Analog input type (optional)E/K/S/T/J thermocouple (support negative temperature)/PT100/PT1000/NTC(NTC10K/NTC50K/NTC100K)/0-10V/0-5V/0-20mA/4-20mA or mixed (7 inch and 10 inch optional: 0-5V and -10V).
Analog output type (optional)0-10V/0-5V/0-20mA/4-20mA or mixed. Optional analog output: 0-10V/0-5V/0-20mA/4-20mA/0-5V/-10V~10V optional (each negative voltage occupies two DA).
palabuhan COMOptional 1 RS485 or 2 RS485 COM ports (one of the RS485 is changed from the default 232); Optional WIFI (will occupy the default port 232). Optional CAN port (2.0A/B), network port. WIFI (will occupy the default 232 port).
Dimensional drawing of the Coolmay QM3G-100FH HMI PLC, showing front, side, and top views kalayan ukuran dina milimeter.

Figure 3: Dimensional drawing for QM3G-100FH, with cutout size 262x180mm.

4. Setup jeung Instalasi

4.1 Ngabongkar bungkusan

Carefully unpack the HMI PLC unit and verify that all components are present:

4.2 Pamasangan

The QM3G-100FH-44MT is designed for panel mounting. Ensure the cutout size in your panel is 262mm x 180mm. Secure the unit using the provided mounting clips or screws.

4.3 suplai kakuatan

The unit requires a DC24V power supply. Connect the positive (+) and negative (-) terminals of the power supply to the corresponding terminals on the HMI PLC. Ensure the power supply is stable and within the specified voltage rentang.

Example wiring setup showing the HMI PLC connected to a laptop via Type-C programming cables and to a DC24V power supply.

Gambar 4: Kelample wiring setup for programming and power supply connection.

5. Diagram Kabel

Proper wiring is crucial for the safe and correct operation of the HMI PLC. Refer to the following diagrams for input, output, and analog wiring.

5.1 Digital Input Wiring (Diagram 10)

The PLC digital input is a passive NPN type. Connect the positive pole of the power supply to the positive pole of the transmitter, the negative pole of the transmitter to the input terminal, and the negative pole of the power supply to the common terminal of the PLC. The input signal is isolated from the power supply.

Diagram 10: PLC digital input wiring showing connections for passive NPN input, power supply, and common terminal.

Figure 5: Diagram 10 Input wiring.

5.2 Relay Output Equivalent Circuit (Diagram 11)

This diagram illustrates the equivalent circuit for relay outputs. Each group of outputs is electrically isolated, and different groups of outputs can be connected to different voltages.

Diagram 11: Relay output equivalent circuit showing connections for load, power supply, and common terminals.

Figure 6: Diagram 11 Relay output equivalent circuit.

5.3 Transistor Output Equivalent Circuit (Diagram 12)

This diagram shows the equivalent circuit for transistor outputs. The output terminals are several groups, each group is electrically isolated. Different groups of outputs cannot be connected to different power circuits.

Diagram 12: Transistor output equivalent circuit showing connections for load, power supply, and common terminals for sink type output.

Figure 7: Diagram 12 Transistor output equivalent circuit.

5.4 Inductive Load Absorption Circuit Schematic (Diagram 13)

When connecting an inductive load, an absorption circuit is recommended to protect the output components. This diagram provides a schematic for such a circuit.

Diagram 13: Inductive load absorption circuit schematic, showing a diode and resistor in parallel with the inductive load.

Figure 8: Diagram 13 Inductive load absorption circuit schematic.

5.5 Pulse Output Wiring Diagram (Diagram 14)

This diagram illustrates the internal circuit for pulse output wiring. Note that the internal circuit in all diagrams is for reference only.

Diagram 14: Pulse output wiring diagram showing internal connections for Y0-Y1 and Y14-Y2 outputs.

Figure 9: Diagram 14 Pulse output wiring diagram.

5.6 PLC Analog Wiring (Diagram 15)

This diagram details the wiring for PLC analog inputs and outputs. Analog input is 12-bit precision, supporting TO instructions or register direct assignment operation. Analog output register (DA) means analog output precision is 12 bit; support TO instructions or register direct assignment operation.

Diagram 15: PLC analog wiring showing connections for analog inputs (AI) and analog outputs (AO) with GND terminals.

Figure 10: Diagram 15 PLC analog wiring.

6. Operasi

The HMI PLC unit operates through its integrated touch screen. The interface allows for monitoring, control, and parameter adjustment of connected industrial processes. Specific operational procedures will depend on the custom program loaded onto the device.

Video 1: Product demonstration showing the HMI PLC interface and touch screen interaction.

7. Pemrograman

The HMI PLC requires programming for both the HMI interface and the PLC logic. The unit comes with a Type-C programming cable for this purpose.

7.1 HMI Programming

Use CoolmayHMI programming software to design and upload the user interface to the HMI part of the device.

7.2 Pemrograman PLC

The PLC part is compatible with Mitsubishi programming software such as GX Developer (versions 8.52/8.86) and GX Works2. Use these tools to develop and upload your control logic.

7.3 Programming Reference

Refer to the programming reference for details on maximum digital points, auxiliary relays, timers, counters, data registers, and other programming elements.

Programming reference table showing maximum digital points, auxiliary relays, timers, counters, and data registers for various QM3G-FH models.

Figure 11: Programming Reference and Statement of Power-down Save.

8. Pangropéa

Regular maintenance ensures the longevity and reliable operation of your HMI PLC. Always disconnect power before performing any maintenance.

9. Cara ngungkulan

This section provides solutions to common issues you might encounter with your HMI PLC.

9.1 Tips ngungkulan Umum

9.2 FAQ

Q: Which PLC is used for communication and programming?
A: The PLC part of the QM3G-100FH-44MT is compatible with Mitsubishi programming software such as GX Developer (versions 8.52/8.86) and GX Works2 for programming and communication.

10. Tips pamaké

Based on user feedback and best practices, consider the following tips for optimal performance and longevity of your HMI PLC:

11. Garansi jeung Rojongan

For warranty information and technical support, please contact your vendor or the manufacturer directly. Coolmay provides technical customer service and remote assistance for their products.

Dokumén Patali - QM3G-100FH-44MT

Praview Coolmay QM3G Series HMI/PLC All-in-One Programming Manual: Features, Specifications, and Operation Guide
This comprehensive programming manual details the Coolmay QM3G Series HMI/PLC All-in-one devices. It covers hardware specifications, programming precautions, PLC and HMI functionalities, communication protocols (Modbus, RS485, CAN, Ethernet), and software usage, providing essential information for engineers and technicians working with Coolmay's industrial automation solutions.
Praview Buku Panduan Pangguna Coolmay QM3G-FH HMI PLC Sadayana-dina-Hiji
Buku pituduh pikeun produk Coolmay QM3G-FH séri HMI PLC All-in-One, anu ngajéntrékeun fitur, spésifikasi, kabel, sareng rujukan pamrograman pikeun otomatisasi industri.
Praview Coolmay PLC Programming Manual V20.81 - Parentah jeung Operasi
Manual programming komprehensif pikeun Controllers runtuyan Coolmay PLC (V20.81), rinci parentah, operasi alat, sarta prinsip programming. Cocog sareng parangkat lunak Mitsubishi.
Praview Coolmay TK6043BH 4.3" Industrial HMI - Fitur, Spésifikasi, sareng Buku Panduan
Inpormasi lengkep ngeunaan Coolmay TK6043BH 4.3 inci HMI, kalebet fitur produk, spésifikasi téknis, dimensi outline, definisi terminal, sareng pedoman pamasangan pangguna.
Praview Coolmay EX3S Series All-in-One PLC User Manual
User manual for Coolmay EX3S series all-in-one touch screen PLC, covering product features, specifications, wiring, installation, and programming guidance.
Praview Coolmay EX3S-28FH and 8043B All-in-One User Manual
Comprehensive user manual for Coolmay EX3S-28FH and 8043B All-in-One touch screen PLC machines, detailing product characteristics, general specifications, wiring methods, electrical design, installation, parameters, communication, and warranty information.