Bubuka
The GEYA GRD9L-R Auto Recloser is an advanced electrical safety device designed to automatically restore power after an electrical fault, specifically earth leakage currents. This device integrates with a Residual Current Circuit Breaker (RCCB), Residual Current Device (RCD), or Earth Leakage Circuit Breaker (ELCB) to provide continuous protection and minimize downtime caused by nuisance tripping. It is suitable for various applications including power grid terminal lines, meter boxes, new energy circuit management, PV solar control boxes, smart electricity systems, smart homes, and electric vehicle charging piles.
This manual provides essential information for the safe and effective installation, operation, and maintenance of your GRD9L-R Auto Recloser.

spésifikasi
The GEYA GRD9L-R Auto Recloser is available in various configurations, including 2-pole and 4-pole versions with different rated currents and sensitivities (30mA, 100mA, 300mA).
spésifikasi umum
- Ngaran Brand: GEYA
- Jumlah modél: GYL9 RCCB Recloser (GRD9L-R series)
- Tipe: Earth Leakage, RCD
- Dipeunteun Voltage: 220/380V
- Modeu kontrol: Auto Recloser
- Sertifikasi: CE
- Asal: Daratan Cina
Technical Parameters (GRD9L-R)
| Parameter | Nilai |
|---|---|
| Modeu kontrol | Otomatis Reclosing |
| terminal suplai | A1-A2 |
| Voltagrentang e (DC) | DC12V or DC24-48V (model dependent) |
| Input kakuatan (DC) | DC max.1W (standby) max.20W (action) |
| Voltagrentang e (AC) | AC 220V (50-60Hz) |
| Pasokan voltage kasabaran | ± 10% |
| Input daya (AC) | AC max.1VA (standby) max.20VA (action) |
| indikasi suplai | LED beureum |
| waktos Peta | ≤1s |
| Auto reclosing times | 3 |
| Auto reclosing interval time | 10s-60s-300s |
| Reset the closing times | No trip or manual reset within 15 minutes after successful closing |
| Kahirupan mékanis | 10000 siklus |
| Electrical life (AC1) | 4000 siklus |
| Suhu operasi | -20°C nepi ka +55°C (-4°F nepi ka 131°F) |
| Suhu neundeun | -35°C nepi ka +75°C (-22°F nepi ka 158°F) |
| Pamasangan | DIN rail EN/IEC 60715 |
| Gelar panyalindungan | IP20 |
| Overvoltage kategori | III |
| Gelar polusi | 2 |
| Max. cable size (mm²) | Solid wire max.1×2.5 or 2×1.5 / with sleeve max.1×2.5 (AWG 12) |
| Dimensions (GRD9L-R module) | 82×18×78mm (H×W×D) |
| Dimensions (GRD9L + GYL9 2P) | 53mm width (combined unit) |
| Dimensions (GRD9L + GYL9 4P) | 88mm width (combined unit) |


Instalasi jeung Wiring
WARNING: Installation should only be performed by a qualified electrician. Ensure power is disconnected before installation to prevent electric shock.
Dipasang dina DIN Rail
The GRD9L-R is designed for DIN rail mounting (EN/IEC 60715).
Cooperation with RCCB/MCB
The GRD9L-R Auto Recloser is designed to cooperate with an RCCB (Residual Current Circuit Breaker) or MCB (Miniature Circuit Breaker).

- Cooperate with RCCB:
- Align the recloser with the RCCB.
- Connect the recloser to the RCCB using the provided accessories.
- Ensure a secure mechanical and electrical connection.
- Cooperate with MCB:
- Align the recloser with the MCB.
- Connect the recloser to the MCB using the provided accessories.
- Ensure a secure mechanical and electrical connection.
- konci nutup: When checking the circuit, the RCCB/MCB cannot close when the lock function is activated. This prevents accidental reclosing during maintenance.
- Accessories Installing: The diagram shows how to install additional accessories (e.g., ARD) alongside the MCB/RCCB and recloser.
Diagram Wiring
Connect the GRD9L-R according to the following diagram. Ensure correct polarity and voltage for the control circuit (A1, A2, COM, NO, NC, AUX) and the main power circuit (L, N, Load).

The wiring diagram illustrates a typical application where the GRD9L-R is connected to an RCCB, protecting multiple loads. An alarm lamp can be connected to the AUX contacts (COM, NO, NC) to indicate the status of the recloser or a persistent fault.
- L: Input kawat langsung
- N: Input kawat nétral
- A1, A2: Control power input (DC12V or AC220V depending on model)
- COM, NO, NC: Auxiliary contacts for alarm or remote indication.
- Beban: Devices protected by the RCCB/Recloser combination.
Parentah Operasi
Pamilihan Mode
The GRD9L-R features a selector switch for operating modes:

- Mode otomatis: The auto reclosing function is enabled. The device will attempt to reclose the circuit breaker automatically after a trip.
- Mode MANU: The auto reclosing function is disabled. The MCB/RCCB can only be opened and closed manually. This mode is typically used for maintenance or when automatic reclosing is not desired.
Power Indicator (PWR LED)
- When powered on, the green indicator will flash for 2 seconds to wait for the power supply to stabilize.
- After stabilization, the green indicator light will stay on.
- If the MCB/RCCB fails to trip, the red indicator light will be on.
- During auto reclosing delay, the red indicator light will flash.
- After a successful reclose, the green light will be on.
Automatic Reclosing Logic (AUTO Mode)
The GRD9L-R attempts to reclose the circuit breaker up to 3 times after a trip, with specific time intervals. If reclosing is successful, the counter resets. If all 3 attempts fail within 15 minutes, the device will lock out and require manual intervention.

Reclosing Sequence:
- 1st Trip: If the MCB/RCCB trips, the recloser waits 10 seconds, then attempts to switch ON.
- 2nd Trip: If it trips again within 15 minutes, it waits 60 seconds, then attempts to switch ON.
- 3rd Trip: If it trips a third time within 15 minutes, it waits 300 seconds, then attempts to switch ON.
- Konci kaluar: If the third attempt fails, or if there are continuous closing failures within 15 minutes, the device enters a locked-out state (LOCK) and will not attempt further reclosing until manually reset or the 15-minute timer expires after a successful reclose.
The closing times are reset if no trip occurs or if a manual reset is performed within 15 minutes after a successful closing.
Pangropéa
The GEYA GRD9L-R Auto Recloser is designed for minimal maintenance. However, regular checks are recommended to ensure optimal performance and safety.
- Inspeksi Visual: Mariksa périodik alat pikeun tanda-tanda karusakan fisik, robahan warna, atanapi sambungan anu leupas.
- Uji fungsionalitas: It is recommended to periodically test the RCCB/RCD functionality as per its own manual. The "Test Monthly" button on the RCCB/RCD should be pressed to ensure it trips correctly.
- Kabersihan: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
- Pariksa profésional: For any concerns or suspected malfunctions, consult a qualified electrician.
Always ensure power is disconnected before performing any inspection or cleaning.
Pamérésan masalah
This section provides guidance on common issues you might encounter with the GRD9L-R Auto Recloser.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Device does not reclose after a trip. |
|
|
| Red PWR LED is continuously ON. | MCB/RCCB failed to trip, indicating a potential issue with the circuit breaker itself or a very high fault current. | Immediately disconnect power and have a qualified electrician inspect the MCB/RCCB and the electrical system. |
| Red PWR LED is flashing. | Device is in an auto reclosing delay period. | This is normal operation. Wait for the reclosing attempt. If it fails, refer to "Device does not reclose" above. |
| Green PWR LED is OFF. | No power supply to the recloser. | Check the main power supply and the control power connections (A1-A2). |
| Closing lock prevents manual operation. | Fungsi konci diaktipkeun. | Deactivate the lock function as shown in the installation diagram (Figure 4). |
If the problem persists after attempting these solutions, contact a qualified electrician or the manufacturer for assistance.
Tip pamaké
- Always ensure that the GRD9L-R is correctly paired with a compatible RCCB/MCB for optimal performance and safety.
- Regularly test your RCCB/RCD by pressing its test button to confirm it is functioning correctly. This ensures the entire protection system is reliable.
- For critical circuits where continuous power is paramount, consider understanding the reclosing delay times to anticipate power restoration.
- If frequent tripping occurs, it indicates an underlying electrical issue that needs to be addressed by a professional, rather than relying solely on the auto-reclose function.
Garansi sareng Rojongan
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Ensure you have your product model number (GRD9L-R) and any relevant purchase details available when seeking support.
Manufacturer: GEYA