The VarioTrack (VT) is a solar MPPT charge controller that recharges a connected battery from photovoltaic (PV) panels in an optimum way. It is designed and manufactured by Studer in Switzerland and is intended for use as part of a battery-based energy management system.
Specifications
| Protection / Class | IP 54, Protection Class I |
|---|---|
| PV Max Voltage | 150 Voc (75 Voc @ 12Vdc) |
| PV Max Current | VT 40: 35A VT 65: 60A VT 80: 75A |
| Battery Nominal Voltage | 12/24/48 Vdc |
| Battery Charge Current | VT 40: 40A VT 65: 65A VT 80: 80A |
| Battery Voltage Range (Min–Max) | 17–68 Vdc |
| PV side cable / terminal torque | VT 40: 10mm² cable, M5, 5Nm VT 65 / VT 80: 25mm² cable, M6, 5Nm |
| Battery side cable / terminal torque | VT 40: 16mm² cable, M5, 5Nm VT 65 / VT 80: 25mm² cable, M6, 5Nm |
| Earthing (grounding) conductor | 16mm² cable |
| Protection device (PV side) – max solar current | VT 40: 35A VT 65: 60A VT 80: 75A |
| PV overvoltage protection | SPD (150Vdc) |
| Protection device (Battery side) – max current | VT 40: 50A VT 65: 80A VT 80: 100A |
| PV input range note | INPUT 0–150Voc (0–75 Voc @ 12Vdc) |
| Series / parallel wiring note | In series, up to 150Voc (75 Voc @ 12Vdc). In parallel, see recommended power table below (as provided): 12V: VT40 625W / VT65 1000W / VT80 1250W 24V: VT40 1250W / VT65 2000W / VT80 2500W 48V: VT40 2500W / VT65 4000W / VT80 5000W |
Quick setup
- Plan installation so the device is installed by qualified personnel and in accordance with local standards and regulations.
- Mount the VT in an appropriate location; batteries should only be installed by qualified personnel.
- Connect PV: use the specified PV cable sizes and terminal torque (VT 40: 10mm², M5, 5Nm; VT 65/VT 80: 25mm², M6, 5Nm) and include a PV side protection device sized to the max solar current.
- Connect battery: use the specified battery cable sizes and terminal torque (VT 40: 16mm², M5, 5Nm; VT 65/VT 80: 25mm², M6, 5Nm) and include a battery side protection device sized to the max current.
- Connect earthing (grounding) using a 16mm² cable and ensure the solar generator is class II isolated.
- Make communication connections as required (RJ45 for RCC 02/03 / multi-units; RJ11 for BTS 01 / ARM 02).
- Apply system power and configure the VarioTrack units using the provided DIP switch configuration and RCC 02/03 configuration interface (when applicable).
- During operation, refer to the display system indicators (status and blinking behavior vary by VT model and current range).
Introduction
Congratulations! You are about to install and use a high-end piece of equipment that will play a central role in the energy management of your battery-based system. The Variotrack (VT) is a solar MPPT charge controller. When connected to a battery and photovoltaic panels, the VT will optimally recharge the battery. This VT has been designed, manufactured, assembled, and tested in our factory in Switzerland.
General Information
Exclusion of liability
Studer disclaims all responsibility and liability for damage, costs or losses resulting from an installation that does not comply with the instructions, a faulty operation or inadequate maintenance. The use of studer equipment is in any case under the responsibility of the customer. Read carefully the safety and operation instructions / Installation must be entrusted to qualified personnel / Check the user manual online / Need help
Compatible with
Mounting and installation
Storage and content
Mounting place
The batteries should only be installed by qualified personnel.
Fixing and dimensions
Wiring
The device must be installed in accordance with local standards and regulations in force
Multi units and power up
Display
Display system
Configuring the variotracks
DIP switches
Vt 80 specificities
Assembling the cooling fan
Technical data
Maintenance and recycling
Except for the periodic check of the connections (tightening, general condition), the variotrack does not require any particular maintenance. To dispose of this product, please use the service for the collection of electrical waste and observe all obligations in force in the place of purchase.
- Serial Number:
- Installed by :
- Date :
- Signature :
- Call our specialists at +41 27 205 60 80
- or visit studer-innotec.com/support
- Studer Innotec SA
- rue des Casernes 57
- 1950 Sion, Switzerland
- info@studer-innotec.com
All rights reserved Studer Innotec SA – V1.2.1
Troubleshooting
- General: If installation, operation, or maintenance does not comply with the instructions, Studer disclaims responsibility for damage, costs, or losses. Verify installation matches the manual and local regulations.
- Connection check: Apart from periodic checks of the connections (tightening, general condition), no particular maintenance is required. If performance issues occur, first inspect and re-tighten connections as appropriate.
- Installation failures: Ensure the device is installed by qualified personnel and that PV/battery connections use the specified cable sizes, protection devices, and overvoltage protection (SPD 150Vdc).
- Status indication: Use the VT display/blinking status indicators (on status and blinking status) to determine whether current ranges correspond to the expected model-specific ranges shown in the manual.
- Need help: Contact Studer specialists via the provided support number or support website if issues persist.
Documents / Resources
![]() | vt80 variotrack (vt) |
References
- Downloads | STUDERstuder-innotec.com
- Studer care: warranty and service | Long-term support & quality - Studer Innotecstuder-innotec.com
- Professional technical support & assistance - Studer Innotecstuder-innotec.com
- User Manualmanual.tools