Overview
The variostring (vs) is a solar MPPT charge controller designed to recharge batteries optimally when connected to batteries and photovoltaic (PV) panels. It was designed, manufactured, assembled, and tested in Switzerland.
Specifications
| Item | Value |
|---|---|
| Protection rating | IP 54 |
| Protection class | Class I |
| PV input voltage (range) | 100–600 V |
| PV maximum current | 13 A |
| PV recommended power | 4200 W |
| Battery nominal voltage | 48 V |
| Battery charge current (max) | 70 A |
| Battery voltage range (min–max) | 38–68 V |
| Network/communications cabling (as listed) | 2× RJ45 (rcc 02/03 / multi-units: xtender, vt, vs, bsp, xcom); 1× RJ11 for accessories (bts 01, arm 02) |
Battery/PV electrical interface details mentioned in the manual include: solar generator input labeled INPUT 0–600Voc; PV connection cable 2.5–6 mm² (Sunclix connector) with max solar current 13 A; serial connection up to 600 V; battery connection cable 25 mm² (M6, 5 Nm). Overvoltage protection (SPD) indicated for 600 Vdc; battery-side protection device indicated 80 A and PV-side protection device mentioned.
Quick guide (setup & use)
- Have the installation performed by qualified personnel.
- Install the device according to local standards and regulations in force.
- Mount and fix the unit; use the indicated fixing/spacing requirements from the manual.
- Wire the system: connect the PV side and battery side using the specified cable types/ratings; ensure the solar generator is class II isolated and follow the manual’s earthing instruction (earthing cable stated as 16 mm²).
- For communication/cascading (if used), connect the listed RJ45/RJ11 cables to the appropriate modules.
- Power up and check the device/display behavior. If the display shows “error” or indicates missing/insufficient PV voltage, refer to the troubleshooting section.
- Configure the variostring using the DIP switches (activate configuration and set battery type/profile as indicated), then check the charging behavior/status on the display.
Troubleshooting
- Device/display on the device is off: Refer to the manual.
- “blink error”: Check the manual.
- Error / No PV voltage or too low: The manual indicates No PV voltage or too low as an error condition; charging current behavior is also described (blink pattern with lower/upper values). Verify PV voltage and that PV is connected properly.
- Charging current indication does not match expected levels: The display indicates charging states via indicator blink patterns corresponding to current ranges (0–15 A, 15–30 A, 30–45 A, 45–70 A). Use these indicators to determine whether the current is in the expected range.
- Equalization start timing: The manual notes a 5 sec – ON/OFF behavior and a 2 sec – start equalization (if activated); if equalization is not starting, confirm it is activated via configuration.