STI SA5500 Select Alert Mini Controllers
Specifications
- Input: 9 VDC Battery, 527 mA Max. or 12-24 VDC, 402 mA Max.
- Dimensions:
- Length: 3.73 in. (94.6 mm)
- Width: 3.87 in. (98.2 mm)
Product Usage Instructions
Battery Installation/Replacement:
- Unscrew the lens to remove it.
- Loosen the PCB screws without removing them.
- Gently rotate the PCB without touching the LEDs or damaging the reflectors.
- Connect the battery and slide it under the retainer.
- Re-install the PCB and tighten the screws securely.
Low Battery Notification/Strobe Control:
Replace the battery when a low battery condition occurs. The low battery LED will flash once per minute, and the sounder will beep once every 3 minutes.
PRODUCT OVERVIEW
INPUT
9 VDC Battery, 527 mA Max.
12-24 VDC, 402 mA Max.
OPERATING TEMPERATURE
-4°F to 140°F (-20°C to 60°C)
BATTERY INSTALLATION/REPLACEMENT
- Unscrew lens to remove.
- Loosen PCB screws (do not remove).
- Gently rotate PCB without touching LED’s and without damaging the reflectors.
- Connect battery and slide under the retainer.
- Reinstall the PCB and tighten the screws.
NOTES
- The internal battery will provide backup power if loss of external power.
- If no internal battery is used, remove all power and move S1-1 to the “OFF” position (see detail S1).
LOW BATTERY OPERATON
Replace battery when low battery condition occurs, Low battery LED flashes 1x per 1 minute and sounder beeps 1x per 3 minutes
S1 – LOW BAT. NOTIFICATION/STROBE CONTRO
WARNING: This product can expose you to chemicals including Dichloromethane, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov. Three-year warranty or a one-year limited warranty (from date of purchase) on most products. See website for details.
Electronic warranty form at www.sti-usa.com/wc14.
- Control with Power Supply
Not supervised
Alarm on close
Turn off low battery notification - Power Supply Plus Battery
Supervised trigger
Alarm on open trigger
Low battery detect on - Battery Only
Supervised trigger
Alarm on open trigger
Low battery detect on
- 2306 Airport Road
- Waterford • Michigan • 48327-1209
- Phone: 24803-9898
- E-mail: info@sti-usa.com • Web: www.sti-global.com
- Taylor House • 34 Sherwood Road • Bromsgrove
- Worcestershire • B60 3DR • England
- Tel: +44 (0)1527 520 999
- E-mail: info@sti-emea.com • Web: www.sti-global.com
- Unit 7A • Lockheed Avenue
- Airport Business Park
- Waterford • X91 HWF2 • Ireland
- E-mail: info@sti-emea.com
FAQ
Q: What should I do if I encounter a low battery situation?
A: When the low battery condition occurs, replace the battery promptly to ensure continued functionality of the device.
Q: Can I use an external power supply with this product?
A: Yes, you can use either a 9 VDC battery or a 12-24 VDC power source with a maximum current rating of 402 mA.
Documents / Resources
![]() |
STI SA5500 Select Alert Mini Controllers [pdf] Installation Guide SA5500, 5501, SA5500 Select Alert Mini Controllers, SA5500, Select Alert Mini Controllers, Alert Mini Controllers, Mini Controllers |