STAHL 9419/08R-YO1-02A5 8SEG Isbus Fieldbus Technology Yokogawa Bus Carrier

STAHL-9419-08R-YO1-02A5-8SEG -Isbus-Fieldbus-Technology-Y-PRODUCT - Copy

9419/08R-YO1-02A5 Art. No. 221456

  • Time- and cost- saving installation on DIN rails or mounting plates
  • High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors
  • Special slot for 9415 series DCM for online transmission of physical layer diagnostics

WebCode 9419B

9419 series bus- Carriers allow 9412 series fieldbus power supplies for FF H1 segments to be in-stalled quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Connectors are integrated in this version to connect the AKB336 system cable for Yokogawa ALF111 host assemblies.

Technical Data

Explosion Protection
Application range (zones) 2
IECEx gas certificate IECEx BVS 09.0042X
IECEx gas explosion protection Ex nA nC IIC T4 Gc
ATEX gas certificate BVS 09 ATEX E 100 X
ATEX gas explosion protection E II 3 G Ex nA nC IIC T4 Gc
FMus certificate 3026646
cFM certificate 3026646C
Marking cFMus Nonincendive for, Class I, Div. 2, Groups A,B,C,D; T4, at Ta = 70 °C Class I, Zone 1, AEx/Ex nA nC IIC T4 , at Ta = 70 °C

9419 6 031 001 1

EAC certificate TS RU S-DE.ME92.B.01076
EAC gas explosion protection 7 2 Ex nA nC IIC T4 Gc X
Certificates ATEX (BVS), Brazil (ULB), Canada (FM), EAC (ENDCE), IECEx (BVS), India (PESO),

USA (FM)

Electrical Data
Version Yokogawa bus-Carrier
Connection electrical data To Yokogawa ALF111 FF H1 hosts
Trunk supply Redundant
Number of segments 8
Number of slots 16 FPS + 1 DCM
Error detection Power Fail (pri / red) Contact “PF” (35 V/100 mA) closed in go-state
Error detection Diagnostic Contact “Dia” (35 V/100 mA) closed in go-state
Auxiliary Power
Nominal voltage 24 V DC
Auxiliary power voltage range 19 to 32 V DC
Voltage range residual ripple ≤ 3,6 Vss

Network Technology

ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2

9419/08R-YO1-02A5 Art. No. 221456

Auxiliary Power
Current consumption Depending on support equipment
Redundant supply Yes, diode-decoupled
Polarity reversal protection Yes
Power dissipation Depending on the carrier equipment
Device Specific Data
Auxiliary power operating condition LED “pri” LED, green

“red” LED, green

DIP switch diagnostics Diagnostics activated

Diagnostics deactivated

DIP switch redundancy Redundant auxiliary power monitoring activated

Redundant auxiliary power monitoring deactivated

Ambient Conditions
Ambient temperature -20 °C … +70 °C
Ambient temperature -4 °F … +158 °F
Storage temperature -40 °C … +80 °C
Storage temperature -40 °F … +176 °F
Maximum relative humidity 95% (without condensation)
Max. operating altitude < 2000 m
Max. operating altitude, ft < 6562 ft
Electromagnetic compatibility Tested to the following standards and regulations: EN 61326 (IEC/EN 61000-4-1 to

61000-4-6 and 61000-4-11), NAMUR NE21

Note For further information, see the 9412 type operating instructions
Mechanical Data
Connection type auxiliary power 2-pole (+, -) on bus-Carrier (pri/red)
Connection type error message contacts 2-pole (+, -) on bus-Carrier (PF/Dia)
Connection type Trunk 3-pole (+, -) on bus-Carrier

3-pole (+, -, shield) on 9412 series fieldbus power supply

Connection type Host / red. Host System connector for Yokogawa AKB336 system cable
Connection type diagnostics 26-pole ribbon cable on 9415 series diagnostics communication module
Connection type cable shields Shield terminal on the bus-Carrier

Shield bus with clamping bracket

Cable shields note For the fieldbus carrier, the clamping brackets must be ordered separately.
Connection earthing Via earth connection terminal
Rigid single-wire connection Trunk 0.2 to 2.5 mm2

Host 0.2 to 2.5 mm2

Auxiliary power 0.2 to 2.5 mm²

Fault message contact 0.2 to 2.5 mm2

Earthing 0.2 to 2.5 mm²

Flexible single-wire connection Trunk 0.2 to 2.5 mm2

Host 0.2 to 2.5 mm2

Auxiliary power 0.2 to 2.5 mm²

Fault message contact 0.2 to 2.5 mm2

Earthing 0.2 to 2.5 mm²

Flexible single-wire connection with sleeve Trunk 0.25 to 2.5 mm2

Host 0.25 to 2.5 mm2

Auxiliary power 0.25 to 2.5 mm²

Fault message contact 0.25 to 2.5 mm2

Earthing 0.25 to 2.5 mm²

Mechanical Data
Two-core connection, flexible Trunk 0.2 to 1.5 mm2

Host 0.2 to 1.5 mm2

Auxiliary power 0.2 to 1.5 mm²

Fault message contact 0.2 to 1.5 mm2

Earthing 0.2 to 1.5 mm²

Two-core connection, rigid Trunk 0.2 to 1 mm2

Host 0.2 to 1 mm2

Auxiliary power 0.2 to 1 mm²

Fault message contact 0.2 to 1 mm2

Earthing 0.2 to 1 mm²

Two-core connection, flexible with sleeve Trunk 0.25 to 1 mm2

Host 0.25 to 1 mm2

Auxiliary power 0.25 to 1 mm²

Fault message contact 0.25 to 1 mm2

Earthing 0.25 to 1 mm²

IP degree of protection (IEC 60529) IP00

IP20 terminals

Module enclosure PA 6.6
Fire resistance (UL 94) V0
Pollutant class Corresponds to G3
Width 358 mm
Width, inches 14.09 in
Length 160 mm
Length, inches 6.3 in
Depth of cut-out 129 mm
Mounting depth, inches 5.08 in
Weight 1.2 kg
Weight 2.65 lb
Mounting / Installation
Mounting type on NS 35/15 DIN rail (DIN EN 60715)

On mounting plate (4 x M5 screw)

Tightening torque 2.6 Nm
Mounting orientation note For further information, see the 9412 type operating instructions
Mounting orientation Horizontal

Vertical

Dimensional Drawings (All Dimensions in mm [inches]) – Subject to Alterations

STAHL-9419-08R-YO1-02A5-8SEG -Isbus-Fieldbus-Technology-Y-FIG-1

9419/08R bus-Carrier for 16 fieldbus segments

Accessories

Diagnostics communication module 9415

STAHL-9419-08R-YO1-02A5-8SEG -Isbus-Fieldbus-Technology-Y-FIG-2 Transmission of diagnostic data for up to eight segments via FF H1 207903

Fieldbus power supply

STAHL-9419-08R-YO1-02A5-8SEG -Isbus-Fieldbus-Technology-Y-FIG-3 Fieldbus supply, diagnostics and adjustable warning level 200588

Spring clamp clip

STAHL-9419-08R-YO1-02A5-8SEG -Isbus-Fieldbus-Technology-Y-FIG-4 Spring clamp clip KLBÜ C01 113509

We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.

ADDRESS: R. STAHL Schaltgeräte GmbH Am Bahnhof 30  74638 WALDENBURG
Tel. +49 7942 943 1700 +49 7942 943 1777
Email: sales.de@r-stahl.com 
r-stahl.com