Installation Guide for STAHL models including: 9419 08R-YO1-02A5 8SEG Isbus Fieldbus Technology Yokogawa Bus Carrier, 9419 08R-YO1-02A5 8SEG, Isbus Fieldbus Technology Yokogawa Bus Carrier, Fieldbus Technology Yokogawa Bus Carrier, Yokogawa Bus Carrier, Bus Carrier
ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2 - 221456
File Info : application/pdf, 4 Pages, 709.61KB
DocumentDocumentNetwork Technology ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2 9419/08R-YO1-02A5 Art. No. 221456 · Time- and cost-saving installation on DIN rails or mounting plates · High availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors · Special slot for 9415 series DCM for online transmission of physical layer diagnostics WebCode 9419B 9419 series bus-Carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for eight segments with simplex supply and for four or eight segments with redundant supply. Connectors are integrated in this version to connect the AKB336 system cable for Yokogawa ALF111 host assemblies. Technical Data Explosion Protection Application range (zones) IECEx gas certificate IECEx gas explosion protection ATEX gas certificate ATEX gas explosion protection FMus certificate cFM certificate Marking cFMus EAC certificate EAC gas explosion protection Certificates Electrical Data Version Connection electrical data Trunk supply Number of segments Number of slots Error detection Power Fail (pri / red) Error detection Diagnostic Auxiliary Power Nominal voltage Auxiliary power voltage range Voltage range residual ripple 2 IECEx BVS 09.0042X Ex nA nC IIC T4 Gc BVS 09 ATEX E 100 X E II 3 G Ex nA nC IIC T4 Gc 3026646 3026646C Nonincendive for, Class I, Div. 2, Groups A,B,C,D; T4, at Ta = 70 °C Class I, Zone 1, AEx/Ex nA nC IIC T4 , at Ta = 70 °C 9419 6 031 001 1 TS RU S-DE.ME92.B.01076 7 2 Ex nA nC IIC T4 Gc X ATEX (BVS), Brazil (ULB), Canada (FM), EAC (ENDCE), IECEx (BVS), India (PESO), USA (FM) Yokogawa bus-Carrier To Yokogawa ALF111 FF H1 hosts Redundant 8 16 FPS + 1 DCM Contact "PF" (35 V/100 mA) closed in go-state Contact "Dia" (35 V/100 mA) closed in go-state 24 V DC 19 to 32 V DC 3,6 Vss 2022-11-25 R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG 1/4 V 0.112 EN Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com Network Technology ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2 9419/08R-YO1-02A5 Art. No. 221456 Auxiliary Power Current consumption Redundant supply Polarity reversal protection Power dissipation Device Specific Data Auxiliary power operating condition LED DIP switch diagnostics DIP switch redundancy Ambient Conditions Ambient temperature Ambient temperature Storage temperature Storage temperature Maximum relative humidity Max. operating altitude Max. operating altitude, ft Electromagnetic compatibility Note Mechanical Data Connection type auxiliary power Connection type error message contacts Connection type Trunk Connection type Host / red. Host Connection type diagnostics Connection type cable shields Cable shields note Connection earthing Rigid single-wire connection Flexible single-wire connection Flexible single-wire connection with sleeve Depending on support equipment Yes, diode-decoupled Yes Depending on the carrier equipment "pri" LED, green "red" LED, green Diagnostics activated Diagnostics deactivated Redundant auxiliary power monitoring activated Redundant auxiliary power monitoring deactivated -20 °C ... +70 °C -4 °F ... +158 °F -40 °C ... +80 °C -40 °F ... +176 °F 95% (without condensation) < 2000 m < 6562 ft Tested to the following standards and regulations: EN 61326 (IEC/EN 61000-4-1 to 61000-4-6 and 61000-4-11), NAMUR NE21 For further information, see the 9412 type operating instructions 2-pole (+, -) on bus-Carrier (pri/red) 2-pole (+, -) on bus-Carrier (PF/Dia) 3-pole (+, -) on bus-Carrier 3-pole (+, -, shield) on 9412 series fieldbus power supply System connector for Yokogawa AKB336 system cable 26-pole ribbon cable on 9415 series diagnostics communication module Shield terminal on the bus-Carrier Shield bus with clamping bracket For the fieldbus carrier, the clamping brackets must be ordered separately. Via earth connection terminal Trunk 0.2 to 2.5 mm2 Host 0.2 to 2.5 mm2 Auxiliary power 0.2 to 2.5 mm² Fault message contact 0.2 to 2.5 mm2 Earthing 0.2 to 2.5 mm² Trunk 0.2 to 2.5 mm2 Host 0.2 to 2.5 mm2 Auxiliary power 0.2 to 2.5 mm² Fault message contact 0.2 to 2.5 mm2 Earthing 0.2 to 2.5 mm² Trunk 0.25 to 2.5 mm2 Host 0.25 to 2.5 mm2 Auxiliary power 0.25 to 2.5 mm² Fault message contact 0.25 to 2.5 mm2 Earthing 0.25 to 2.5 mm² 2022-11-25 R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG 2/4 V 0.112 EN Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com Network Technology ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2 9419/08R-YO1-02A5 Art. No. 221456 Mechanical Data Two-core connection, flexible Two-core connection, rigid Two-core connection, flexible with sleeve IP degree of protection (IEC 60529) Module enclosure Fire resistance (UL 94) Pollutant class Width Width, inches Length Length, inches Depth of cut-out Mounting depth, inches Weight Weight Mounting / Installation Mounting type Tightening torque Mounting orientation note Mounting orientation Trunk 0.2 to 1.5 mm2 Host 0.2 to 1.5 mm2 Auxiliary power 0.2 to 1.5 mm² Fault message contact 0.2 to 1.5 mm2 Earthing 0.2 to 1.5 mm² Trunk 0.2 to 1 mm2 Host 0.2 to 1 mm2 Auxiliary power 0.2 to 1 mm² Fault message contact 0.2 to 1 mm2 Earthing 0.2 to 1 mm² Trunk 0.25 to 1 mm2 Host 0.25 to 1 mm2 Auxiliary power 0.25 to 1 mm² Fault message contact 0.25 to 1 mm2 Earthing 0.25 to 1 mm² IP00 IP20 terminals PA 6.6 V0 Corresponds to G3 358 mm 14.09 in 160 mm 6.3 in 129 mm 5.08 in 1.2 kg 2.65 lb on NS 35/15 DIN rail (DIN EN 60715) On mounting plate (4 x M5 screw) 2.6 Nm For further information, see the 9412 type operating instructions Horizontal Vertical Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 130 [5,12] 144 [5,67] 359 [14,13] 9419/08R bus-Carrier for 16 fieldbus segments Accessories Diagnostics communication module 9415 160 [6,30] 62 [2,30] 2022-11-25 V 0.112 EN R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com Art. No. 3/4 Network Technology ISbus fieldbus technology Yokogawa bus-Carrier For Zone 2 9419/08R-YO1-02A5 Art. No. 221456 Transmission of diagnostic data for up to eight segments via FF H1 Fieldbus power supply Fieldbus supply, diagnostics and adjustable warning level Spring clamp clip Spring clamp clip KLBÜ C01 207903 Art. No. 200588 Art. No. 113509 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 2022-11-25 R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG 4/4 V 0.112 EN Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com