POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway Installation Guide

POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - front banner

  1. Hlakola 'me u bule Metron5
    Place unit on a flat surface. To open, loosen the 2 nylon screws in the bottom corners of the Metron5 and 4 screws around battery enclosure.
    Allen key and Pozi / Phillips head screwdriver required.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Unpack & Open Up the Metron 5
  2. Hloekisa Solar Panel
    Solar panel e tla e khomaretsoe ka har'a bracket e ntseng e phahama. Phanele e tlameha ho shebana le boroa ka kotloloho mme e be le a view of at least 100° of unobstructed sky.
    The panel should be tilted at an angle 10° to 15° plus the site’s latitude from the horizontal to achieve maximum sun exposure (example overleaf).
    The higher the cell, the better.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Mount the Solar Panel
  3. Thaba ea Metron5
    Ideally a flat surface such as a wall/ DIN railing/Unistrut railing.
    Qoba ho kenngoa ka har'a likhabinete tsa tšepe kapa ka tlas'a lefatše (ho ka fokotsa letšoao).
    There are pre-drilled holes for easy mounting.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Mount the Metron5
  4. Hokela Battery
    Ensure the highlighted switch is positioned at “Solar”. Remove the white plastic cover from the battery terminals.
    Use the loose black and red wires and slide on to connect to the battery terminals.
    Maintain polarity:
    Black to black (-). Red to red (+).
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Connect the Battery
  5. Hokela Senso(s)
    The inputs shown in the blue box connect directly to the inputs in the yellow box on the Metron5 above Run the sensor cable(s) through the lower unit’s glands.
    Unplug the green connector(s) and wire in as required. Plug the connector(s) back into the correct input channel and tighten the gland. Ensure cable is through the gland.
    Reattach all lids and take care to tighten screws to ensure waterproof IP67 rating is maintained.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - wire sensor
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Connect the Sensors
  6. Tsamaisa Metron5
    Tobetsa konopo efe kapa efe ho tsosa Metron5. Tobetsa ka ho le letšehali ho potoloha likanale bakeng sa ho bala hanghang (config. dependent) kapa kenya PIN (1234) ebe o tobetsa hang ka mor'a nomoro ea 4 ho kenya leqephe la lapeng.
    Eya tlase ho Force Transmit le ho le letona ho khetha. Sheba sebaka sa tsoelo-pele ebe u emela hore yuniti e fetisoe. Hang ha e felile, data e ka ba teng viewed ka MetronView. Yuniti e tla bala metsotsoana e 45, ebe o kenya Run Mode. Skrine se tla tima.
    For live channel readings, channels can be selected from the menu by pressing right on Channels and then Read Now.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - Navigate the Metron5
  7. View Lintlha
    Etela: 2020.metronview.com
    Hang ha o kentsoe, kakaretso ea li-unit e tla bonahala. Tobetsa view ka letsohong le letšehali la lebitso la sesebelisoa ho bona data ea nalane.
    POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - View Lintlha
  8. Lenaneo
    Liyuniti li ka hlophisoa u le hole le MetronView. It is possible to change how often readings are taken & sent, alter scaling and alarm thresholds for each input channel and much more.
    To make changes contact PowTechnology support.
    The configuration will be held on the server and downloaded to the device when it next communicates.
    Select ‘Force transmit’ rather than waiting for the next time the device transmits in order to reconfigure sooner.

Hlokomela

Ho hloleha ho beha solar panel hantle ho latela melao e boletsoeng ka holimo ho ka etsa hore yuniti e hlolehe bohareng ba Mariha. Haeba motlakase o tsoa ho feta kamoo ho neng ho lebelletsoe (ho tsoa ho mats'oao a fokolang kapa liteko tse ngata hape), ho ka hlokahala phanele ea bobeli ea solar.

Common Latitudes:

  • London: 51.5º; Cardiff: 51.5º; Birmingham: 52.5º;
    Leeds: 54.0º; Belfast: 54.5º; Edinburgh: 56.0º; Aberdeen: 57.0º
  • Example calculation:
    London = 51.5º + 10 = 61.5º tilt angle from the horizontal

POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway - back page
support@powtechnology.com

Litokomane / Lisebelisoa

POWER TECHNOLOGY M5-SOL-SYS Sensor Gateway [pdf] Tlhophiso Tataiso
M5-SOL-SYS, M5-SOL-SYS Sensor Gateway, M5-SOL-SYS, Sensor Gateway, Gateway

Litšupiso

Tlohela maikutlo

Aterese ea hau ea lengolo-tsoibila e ke ke ea phatlalatsoa. Libaka tse hlokahalang li tšoailoe *