Instruction Manual for westermo models including: MMDD-4-545LVA-CHV, MD-45 HV Converter, MD-45 HV, Converter
WESTERMO MD-45 HV (01) PDF MANUAL - Manual-Hub.com
File Info : application/pdf, 16 Pages, 1.23MB
DocumentDocument©Westermo Teleindustri AB · 2003 · REV.A MMDD-4-545LVA/CH V INSTALLATION MANUAL 6157-2213 Galvanic Isolation Transient Balanced CE Protection Transmission Approved Converter RS-232 RS-422/485 www.west er m o.us https://manual-hub.com/ C ont ent s 1. Int roduct ion ............................................................................................................................................................... 3 2. Safet y .................................................................................................................................................................................. 4 3. Approvals ....................................................................................................................................................................... 4 3.1 Declaration of conformity ........................................................................................................................ 5 4. Specifications ............................................................................................................................................................ 6 4.1 Interfaces ............................................................................................................................................................... 6 4.2 Insulation between interfaces ................................................................................................................ 6 4.3 Climatic environment .................................................................................................................................. 7 4.4 Mechanics .............................................................................................................................................................. 7 5. Maint enance .............................................................................................................................................................. 7 6. Inst allat ion ................................................................................................................................................................... 8 6.1 Mounting /Removal ........................................................................................................................................ 8 6.2 Connections ......................................................................................................................................................... 9 6.2.1 LED indicators ........................................................................................................................................ 9 6.2.2 Power (MD-45 H V, AC) ................................................................................................................. 10 6.2.3 Power (MD-45 LV) ............................................................................................................................ 10 6.2.4 Line connection (RS-422/485) ................................................................................................. 10 6.2.5 Terminal connection (RS-232, DCE) .................................................................................. 10 6.3 Configuration ................................................................................................................................................... 11 6.3.1 DIP switch settings ................................................................................................................. 1112 7. Functional description .............................................................................................................................. 13 7.1 Block diagram ................................................................................................................................................. 13 7.2 2 Line connection ......................................................................................................................................... 14 7.3 H ints ....................................................................................................................................................................... 14 2 6157-2213 https://manual-hub.com/ 1. Intruduction The MD-45 is used to convert between RS-422/485 and RS-232/V.24 signals.This device is often used in multidrop applications connected to a PC or PLC. In 2-wire half duplex applications (RS-485) the direction of the bus can be controlled by data which means that the converter turns the bus depending on the data sent on the bus. This makes it possible to use the unit with equipment that has no handshaking signals.The maximum transmission rate possible is 115.2 kbit/s. 1234 R+ R- T+ T- 56789 T+ T- R+ R- CHANNEL 3 CHANNEL 4 LD-01 DC PWR RD TD DCD2 DCD3 DCD4 CHANNEL 2 POWER 123456789 R+ R- T+ T- T+ T- R+ R- CHANNEL 3 CHANNEL 4 LD-01 DC PWR RD TD DCD2 DCD3 DCD4 CHANNEL 2 POWER 123456789 R+ R- T+ T- T+ T- R+ R- CHANNEL 3 LD-01 DC PWR RD TD DCD2 DCD3 DCD4 CHANNEL 2 POWER 6157-2213 3 https://manual-hub.com/ 2. Safety ! General: Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. ! Before installation, maintenance or modification work: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. ! I nst allat ion: This unit should only be installed by qualified personnel. This unit should only be installed in a "restricted access area", for example a lockable cabinet where access is restricted to service personnel only. This unit is intended for permanent connection to the AC/DC mains supply. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the AC/DC mains supply. Ensure compliance to national installation regulations. Unit with the rated voltage exceeding 42.4 V peak or 60 VDC, is defined as class I equipment with a protective earthing conductor terminal. Unit with the rated voltage up to 42.4 V peak or 60 VDC, is defined as class III equipment and shall be separated from hazardous voltage by double or reinforced insulation. This unit uses convection cooling.To avoid obstructing the air flow around the unit, follow the spacing recommendations (see under chapter Installation). 3. Approvals Conformity with the Directive 73/23/EEC (Low Voltage Directive) has been assessed by application of the standard EN 60 950. Conformity with the Directive 89/339/EEC (Electromagnetic compatibility) has been assessed by application of standards EN 61000-6-2 (industrial immunity) and EN 61000-6-3 (residential emission). 4 6157-2213 https://manual-hub.com/ 3.1 Declaration of conformity Westermo Teleindustri AB Declaration of conformity The Westermo Teleindustri AB company declares that the listed products conforms to the Council Directive 89/336/EEC, related to Electro Magnetic Compability and 72/23/EEC Low Voltage Directive. Type of equipment: Model: DIN-rail converter RS232-RS422/485 MD-45 AC 3157-0101, 3157-0110 MD-45 HV 3157-1101 MD-45 LV 3157-0001 Standards: EMC: Safety: EN 61000-6-3/CISPR22(EN 55022): Class B EN 61000-6-2/EN 61000-4-2 EN 61000-6-2/EN 61000-4-3 EN 61000-6-2/EN 61000-4-4 EN 61000-6-2/EN 61000-4-5 EN 61000-6-2/EN 61000-4-6 EN 61000-6-2/EN 61000-4-11 EN 61000-6-2/EN 61000-4-16 EN 60950 Reference: Installation manual MD-45 AC/HV,LV Art. Nr. 6157-2003 Hans Levin Technical Manager May 2003 Postadress/Postal address S-640 40 Stora Sundby Sweden Tel. 016 - 42 80 00 Telefax 016 ñ 42 80 01 Postgiro 52 72 79-4 Int +46 16 42 80 00 Int +46 16 42 80 01 Bankgiro 5671-5550 Org.nr/ Corp. identity number 556361-2604 Ste/ Registered office Eskilstuna 6157-2213 5 https://manual-hub.com/ 4. Specifications 4.1 Interfaces Power Model description MD-45 AC Rated voltage 230 VAC Operating voltage 207253 VAC Rated currant 22 mA MD-45 LV 1230 VAC 1248 VDC 1045 VAC 9,660 VDC 300 mA Rated frequency Polarity Connection Connector size Fuse 4862 Hz 4862 Hz PE, L and N Independent 3-pos screw block 2-pos screw block 0.2 2.5 mm2 (AWG 24-12) To be externally fused MD-45 HV 95240 VAC 110250 VDC 85.5264 VAC 88300 VDC 25 mA @ 240 V, 50 mA @ 95 V 4862 Hz PE, L and N 3-pos screw block RS-485/422 Electrical specification Data rate Connection Connector size Circuit type RS-422/485 1 200 115 200 bit/s 5-pos screw block 0.2 2.5 mm2 (AWG 24-12) TNV-1 RS-232 Electrical specification Data rate Connection Circuit type RS-232-C 1 200 115 200 bit/s 9-pos D-sub, DCE SELV 4.2 Insulation between interfaces Power (MD-45 HV and AC) to all other 3.0 kV RMS @ 50 Hz and 60 s duration Power (MD-45 LV) to all other 1.0 kV RMS @ 50 Hz and 60 s duration RS-232 to RS-485/422 1.0 kV RMS @ 50 Hz and 60 s duration 6 6157-2213 https://manual-hub.com/ 4.3 Climatic environment Temperature, operating Temperature, storage and transportation Relative humidity, operating Relative humidity, storage and transportation 5 to 55ºC 25 to 70ºC 5 to 95% (non-condensing) 5 to 95% (condensation allowed outside packaging) 4.4 Mechanics Dimension (W x H x D) Weight Mounting Degree of protection 55 x 100 x 128 mm 0.5 kg AC, 0.25 kg HV and LV 35 mm DIN-rail IP 20 (IEC 529) 5. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 6157-2213 7 https://manual-hub.com/ 6. Installation 6.1 Mounting /Removal ! Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Mounting This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the air flow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting, see figure. Min 10 mm 25 mm 25 mm CLICK! Removal Press down the black support at the back of the unit using a screwdriver, see figure. 8 6157-2213 https://manual-hub.com/ 6.2 Connections Terminal connection 9-pos screw block RS-232 LED's Terminal connection 9-pos D-sub RS-232 Line connection RS-422/485 Power 6.2.1 LED indicators PWR RTS TD RD CTS Power Indication Request To Send modem signal Transmitted Data: Displays data received from the local RS-232/422/485 port Received Data: Displays data leaving the modem on the RS-232/422/485 port Clear To Send modem signal 6157-2213 9 https://manual-hub.com/ 6.2.2 Power (MD-45 H V,AC) 3-pos screw terminal Description NL L Line N Neutral Protective earth 6.2.3 Power (MD-45 LV) 2-position screw terminal Description No. 1 12 Voltage No. 2 +Voltage 6.2.4 Line connection (RS-422/485) 5-position screw terminal No. 1 No. 2 No. 3 No. 4 No. 5 Direction In In In/Out In/Out Description A' (R+) B' (R) A (T+) B (T) Shield 12 3 45 6.2.5 Terminal connection (RS-232, DCE) 12 3 456 7 89 Screw terminal 7 8 9-pos D-sub 2 3 Direction Out In Description Receive Data (RD) Transmit Data (TD) 1 2 3 4 5 6 7 8 9 1 & 9 5 - Signal ground (SG) 2 6 Out Data set ready (DSR) 6 7 In Request to send (RTS) 5 8 Out Clear to send (CTS) Screw terminal 3 and 4 not used 10 https://manual-hub.com/ 6157-2213 6.3 Configuration S2:1-4 S1:1-8 1 2 34 5 6 7 8 9 6.3.1 DIP-switch settings DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the modem. ! W arning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top of the modem is removed. ! W arning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. NOTE! The change of DIP-switch settings are valid only after a power on. If configured by any other method during normal operation, this new configuration override the DIP-switch settings. However, after a new power on the DIP-switch settings have precedence. 6157-2213 https://manual-hub.com/ 11 Selection of data rate ON S1 1 2 34 56 78 Data rate 1 200 Turning time 780 µs ON S1 1 2 34 56 78 2 400 410 µs ON S1 1 2 34 56 78 4 800 220 µs ON S1 1 2 34 56 78 9 600 130 µs ON S1 1 2 34 56 78 19 200 48 µs ON S1 1 2 34 56 78 38 400 34 µs ON S1 1 2 34 56 78 57 600 22 µs ON S1 1 2 34 56 78 115 200 11 µs Data or RTS-control ON S1 Data control 1 2 34 56 78 ON S1 RTS-control 1 2 34 56 78 ON S1 Transmitter 1 2 3 4 5 6 7 8 always active Factory settings ON S1 1 2 34 56 78 ON S2 1234 S1: 8 not used 12 Selection of bits ON S1 9 1 2 34 56 78 ON S1 10 1 2 34 56 78 ON S1 11 1 2 34 56 78 ON S1 12 1 2 34 56 78 2/4-wire transmission ON S1 2-wire 1 2 34 56 78 ON S1 1 2 34 56 78 4-wire Termination with fail-safe * ON S2 Terminated (4-wire) 1234 ON S2 Terminated (2-wire) 1234 ON S2 No termination 1234 * The fail-safe function forces the signal state of the receiver to OFF when the connected transmitter is in tri-state (transmitter inactive). The receiver located furthest away shall be terminated. Supervision table when selecting data bits 7 bits 8 bits No parity Parity 1 stop bit 2 stop bits · · · · · · · ·· ·· · · · · ·· · · ·· · · · Number of bits 9 10 10 10 11 11 11 12 6157-2213 https://manual-hub.com/ 7.0 Functional description When the converter is set to data-control mode the transmitter is activated by data on TD (RS-232).The time the transmitter stays active corresponds to one character-time and turning time for the set data rate and number of bits. If there is more data on TD before the turning time is ended the transmitter stays active for additional one character. In RTS-control mode the transmitter is activated by the RTS-signal. In this mode the switches for data rate and number of bits has no effect.The LED indicators is controlled by the data signals.The active termination secures that the signal level at the receiver is in off-state (>0.2 Volts) when there is no data transmission. Full duplex is only possible if RS-422 is used. 7.1 Block diagram V.24/RS-232 3 TD 7 RTS 8 CTS TD LED RTS LED CTS LED 6 DSR RD 2 5 SG +5V RD LED MCU S1:6 0VA +5VA 0VA V.11/RS-422 RS-485 3A 4B S2:4 S2:3 +5VB Bus termination 0VB +5VB Bus termination 0VB S2:2 S2:1 1 A' 2 B' 0VB 5 Shield Power F1 Insulated power supply supply +5VB 0VB 6157-2213 https://manual-hub.com/ 13 7.2 Line connection 4-wire MD-45 1 Receiver A' 2 B' 3 Transmitter A 4 B Shield *) 5 Twisted pairs RS-422/485 equipment 2-wire MD-45 RS-422/485 equipment A Transmitter B A' Receiver B' Twisted pairs 3 Transmitter/ A/A' Receiver 4 B/B' A/A' Transmitter/ B/B' Receiver Shield *) 5 *) If shielded cable is used, connect the shield only at one end to avoid ground currents. 7.3 H ints RS-422/485 was designed for multidrop applications. When a system is installed it should form a bus structure (see diagrams). Star shaped networks should never be created, there are other Westermo products designed to work in star net applications. To get a correct installation according to the RS-422/485 specification it´s very important that the line is terminated at the correct points. The recommendation is to terminate the receiver on the master unit and the final bus slave unit. See diagrams for details of how this is done with RS-485 (2-wire) and RS-422 (4-wire). The line transmitter used in the MD-45 is activated by data received on the RS-232 interface, unlike conventional converters that rely on a control signal (e.g. RTS). If any problems do occur on set up of the MD-45, the LED's will be helpful. · PWR: · RD: · CTS: · RTS: · TD: The unit has power. Data received on the RS-422/485 interface. Follows RTS. Status of RTS from the RS-232 interface. Data received on RS-232 interface. Max 1 200 metres A B Max 0.3 metre BA BA BA =Termination Max 32 connections A' B' A B =Termination B' A' B A B' A' B A Max 32 connections B' A' B A N.B. R+/R, T+/T definitions are not standard, it can help to shift A and B if the unit does not work. 14 6157-2213 https://manual-hub.com/ OWN COMMENTS ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... ..................................................................................................................................................................................................................... 6157-2213 15 https://manual-hub.com/ Application examples PWR RD1 TD1 RD2 TD2 RD3 TD3 RD4 TD4 R D TD D CD RTS CTS DTR R D TC ACCESS XX-00 PWR RD1 TD1 RD2 TD2 RD3 TD3 RD4 TD4 R D TD D CD RTS CTS DTR R D TC ACCESS XX-00 PWR RD1 TD1 RD2 TD2 RD3 TD3 RD4 TD4 R D TD D CD RTS CTS DTR R D TC ACCESS XX-00 6157-2213 03.06 Mälartryck AB, Eskilstuna, Sweden W estermo W eb site: www.westermo.us Westermo US Phone 877-268-3700 Fax 877-268-9700 Web site: www.westermo.us https://manual-hub.com/