Leviton 15-Amp 125-Volt NEMA 5-15R Narrow Body Single Receptacle (Model T5015-W) User Manual
Model: T5015-W
Hyrje
This manual provides instructions for the safe installation, operation, and maintenance of your Leviton 15-Amp 125-Volt NEMA 5-15R Narrow Body Single Receptacle, Model T5015-W. Please read these instructions thoroughly before beginning installation to ensure proper function and safety.
Informacion i rëndësishëm për sigurinë
PARALAJMËRIM: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Do not use this device with aluminum wiring. Use only with copper or copper-clad wire.
- Siguroni tokëzimin e duhur për të parandaluar goditjen elektrike.
- Ky produkt përmban kimikate që Shteti i Kalifornisë i njeh si shkaktarë të kancerit dhe defekteve të lindjes ose dëmtimeve të tjera riprodhuese (paralajmërimi i Propozimit 65).
Produkti Mbiview
The Leviton T5015-W is a commercial-grade, 15-Amp, 125-Volt, NEMA 5-15R single receptacle designed for durability and reliable performance in various applications. Its narrow body design allows for maximum wiring room within the electrical box, simplifying installation.

Image: Leviton 15-Amp 125-Volt NEMA 5-15R Narrow Body Single Receptacle in White.
Karakteristikat kryesore:
- Large-head terminal screws, backed out and staked, accept No. 10 copper or copper-clad wire.
- Heavy-Duty brass power contacts for maximum conductivity and plug retention.
- Shallow design for maximum wiring room in box.
- Convenient washer-type break-off plaster ears for best flush alignment.
- Captive mounting screws for fast installation where applicable.
- Total Power Outlets: 1.
Konfigurimi dhe instalimi
Mjetet e nevojshme:
- Kaçavidë (Phillips dhe/ose me kokë të sheshtë)
- Strippers teli
- Vëlltage Testues
- Shirit elektrik (opsional)
Hapat e instalimit:
- Fikni energjinë: Gjeni çelësin e qarkut ose siguresën që kontrollon prizën që po zëvendësoni ose instaloni. Fikeni. Verifikoni që energjia elektrike është e fikur duke përdorur një volt.tage testues.
- Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
- Shkëputni telat: Note the wire connections. Typically, black (hot) wires connect to brass screws, white (neutral) wires to silver screws, and bare copper or green (ground) wires to the green screw. Disconnect all wires.
- Përgatitni telat: If necessary, strip approximately 1/2 inch (12-13 mm) of insulation from the ends of the wires. Ensure wires are straight and free of nicks.
- Connect Wires to New Receptacle:
- Connect the bare copper or green ground wire to the green grounding screw.
- Connect the white (neutral) wire(s) to the silver terminal screw(s).
- Connect the black (hot) wire(s) to the brass terminal screw(s).
- Tighten all terminal screws firmly. Ensure no bare wire is exposed beyond the terminal screws.

Imazh: Nga afër view of the back of a receptacle, showing the green, silver, and brass terminal screws for wiring connections.
- Montimi i prizës: Carefully fold the wires into the electrical box. Insert the new receptacle into the box and secure it with the provided mounting screws. Use the plaster ears for flush alignment.
- Instaloni pllakën e murit: Attach the wall plate over the receptacle.
- Rivendosni energjinë: Ndizni përsëri energjinë te çelësi i qarkut ose te kutia e siguresave.
- Test: Test the receptacle with a known working electrical device.
Udhëzimet e funksionimit
To operate the Leviton T5015-W receptacle, simply insert the plug of your electrical device into the outlet slots. Ensure the plug is fully inserted for a secure connection. This single receptacle provides one power outlet for standard 125-Volt devices.
Mirëmbajtja
Regularly inspect the receptacle and wall plate for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the receptacle. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the finish or internal components.
Zgjidhja e problemeve
Pa energji në prizë:
- Check the circuit breaker or fuse for the circuit. Reset the breaker or replace the fuse if tripped/blown.
- Ensure all wire connections are secure at the receptacle and in the electrical box. Turn off power before checking connections.
- Verify that the power supply to the circuit is active using a voltage testues.
Loose Plug Connection:
- If plugs feel loose or fall out easily, the receptacle may be worn and require replacement to ensure a safe and reliable connection.
Specifikimet
| atribut | Vlera |
|---|---|
| Markë | Leviton |
| Numri i modelit | T5015-W |
| Amptërbim | 15 Amps |
| Vëlltage | 125 volt |
| Konfigurimi NEMA | 5-15R |
| Shtyllat / Telat | 2-Pole, 3-Wire Grounding |
| Lloji i enës | Single, Straight Blade |
| Lloji i instalimeve elektrike | Me kabllo nga mbrapa dhe anash |
| Materiali | Bakër (kontakte) |
| Ngjyra | E bardha |
| Dimensionet e produktit | 12 x 9.13 x 9.38 inç |
| Pesha e artikullit | 2.11 ons |
Informacioni i Garancisë
Leviton products are backed by a limited warranty. For specific warranty details and terms, please refer to the warranty documentation included with your purchase or visit the official Leviton webfaqe interneti. Ruajeni provën e blerjes për çdo kërkesë garancie.
Mbështetje
For technical assistance, troubleshooting, or further information regarding your Leviton T5015-W receptacle, please visit the official Leviton website or contact Leviton customer service. Contact details can typically be found on the product packaging or the company's webfaqe.