Type E Self-Protected Manual Motor Controller
Enclosed Series KTA9
KTA9 Type E Self-Protected Manual Motor Controller
Amp / Horsepower Rating | Non-metallic (IP65) Enclosure![]() |
||||||
Max. Horsepower 000 | 0/L Relay Ampere Range 0.10…0.16 |
1Magnetic Res. r..) Current |
Catalog Number 0 KTA9-32S-0.16A-CG |
1 Dimension Code | |||
Three Phase | |||||||
200V — |
230V — |
460V — |
575V — |
||||
— | — | 0.16…0.25 | 4. | KTA9-32S-0.25A-CG | AY | ||
— | — | 0.25…0.40 | 6. | KTA9-32S-0.4A-CG | AY | ||
— | — | 0.40…0.63 | 9. | KTA9-32S-0.63A-CG | AY | ||
— | 1/2 | 1/2 | 0.63…1.0 | 14 | KTA9-32S-1.0A-CG | AY | |
— | 3/4 | — | 1.0…1.6 | 22 | KTA9-32S-1.6A-CG | AY | |
1/2 | 1/2 | 1 | 1-1/2 | 1.6…2.5 | 35 | KTA9-32S-2.5A-CG | AY |
3/4 | 3/4 | 2 | 3 | 2.5…4.0 | 52 | KTA9-32S-4.0A-CG | AY |
1 | 1-1/2 | 3 | 5➍ | 4.0…6.3 | 88 | KTA9-32S-6.3A-CG | AY |
2 | 2 | 5 | 7/1/2➍ | 6.3…10 | 140 | KTA9-32S-10A-CG | AY |
3 | 5 | 10 | 10➍ | 10…16 | 224 | KTA9-32S-16A-CG | AY |
5➍ | 5➍ | 10➍ | 15➍ | 14.520 | 280 | KTA9-32S-20A-CG | AY |
5➍ | 7/1/2➍ | 15➍ | 20➍ | 18…25 | 330 | KTA9-32S-25A-CG | AY |
7/1/2➍ | 10➍ | 20➍ | 25➍ | 24…29 | 406 | KTA9-32S-29A-CG | AY |
7/1/2➍ | 10➍ | 20➍ | 30➍ | 27…32 | 448 | KTA9-32S-32A-CG | AY |
- Horsepower ratings shown in the table above are for reference. The final selection of the controller depends on the actual motor full load current and service factor.
• For motor with service factor less than 1.15. Use motor nameplate full load current times 0.9 and choose the motor starter with the appropriate current range. Example: Motor FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select catalog number KTA9-32S-4.0A. - Magnetic trip is fixed at 14x the maximum value of the current adjustment range. Refer to page F5 for applied KAIC ratings.
- KTA9 may be applied to single phase loads if 3 poles of device are wired in series. See footnote 1 for device selection criteria.
- A red and yellow handle may be selected instead of the standard gray and black handle. Change “CG” suffix to “CJ”. Ex: Change KTA9-32S-0.16A-CG to KTA9-32S- 0.16A-CJ.
- Handles are built-in to the enclosure and are not available as components.
- Catalog numbers with specific voltages (i.e. @ 575V) shaded in gray are suitable for use as a manual motor starter only because they are not Type E rated. See page F5 for ratings.
Includes:
- Non-metallic (IP65) enclosure with integrated IP65 operator – watertight, dusttight
- KTA9-32S (Standard Interrupting Capacity) “Type E” Self-protected Combination Manual Controller ➎
- Terminal Adaptor for Type E Applications (Cat.# KT9-40-TE)
- Gray and black IP65 handle ➍➎
Enclosure Only
Description | Catalog Number Price |
Gray/Black handle | KT9-ENN |
Red/Yellow handle | KT9-ENRY |
Modifications (Factory Assembled)
Description | Add Suffix to Cat. Number |
KT9 Auxiliaries & Trip Contacts, Front Mount 250V max. 1 NO Auxiliary 1 NC Auxiliary 1 NO + 1 NC Auxiliary 2 NO Auxiliaries 1 NO SC+OL + 1 NC Auxiliary 1 NO SC+OL + 1 NO Auxiliary Side Mount 600V max. 2 NC Auxiliaries 2 NO Auxiliaries 1 NO + 1 NC Auxiliary |
-B -A -C -D -R -S -AS02 -AS20 -AS11 |
Additional KT9 Trip Contacts,Side Mount 600V max. 1 NO SC+OL+1 NO SC 1 NO SC+OL+1 NC SC 1 NC SC+OL+1 NO SC |
-R00 -R01 -R10 |
Accessories Undervoltage Release Module Shunt Release Module |
-UA-✱ -AA-✱ |
-UA..-AA Coil Codes (✱)
AC Coil Code | Voltage Range | |
50 Hz | 60 Hz | |
24V | 21V | 24V |
28V | 24V | 28V |
120V | 105V | 120V |
127V | 110V | 127V |
230V | 220…230V | – |
240V | – | 240…260V |
277V | 240V | 277V |
460V | 380…400V | 400…460V |
480V | 415V | 480V |
600V | 550V | 600V |
SSNA2018