Solar Log SCB V1.2 String Connection Box
USER GUIDE
1. The Kernel SCB
1.1 General
The Kernel from Kernel Sistemi is compatible with the Solar-Log Base 2000.
Up to 60 Kernel SCBs can be connected to a single Solar-Log Base 2000.
You have to request and enter a license code before you can select and configure the Kernel SCB.
Steps for purchasing and importing a license for the Solar-Log™:
- Go to the license portal at https://shop.solar-log.com.
- Log on with your Enerest account.
- After you have to enter the serial number of the Solar-Log™, a list of compatible licenses is displayed.
- You can only select one license from the list. After the selection has been made, the web-shop payment options appear.
- After the payment confirmation, the license is valid.
Automatic import:
- Go to the Configuration | System | Licenses WEB menu of the Solar-Log™.
- Click on Synchronize.
- Now the Solar-Log™ connects to the license server and downloads all of the active licenses.
Manual import:
- Download the license file from the License portal.
- Go to the Configuration | System | Licenses WEB menu of the Solar-Log™.
- Click on the plus symbol and select the license file.
After importing the license, it is activated immediately and „Installed“ is displayed.
Note
Licenses are linked to the device (serial number). The license has to be purchased again if a device has been replaced after the warranty has expired.
Note
If a Solar-Log™ with a license has a defect during the warranty period, a license can be requested for the replacement device. There are no costs involved, provided that the defective device is returned to Solar-Log GmbH.
1.2 Introduction
The configuration described in this document refers to the Kernel SCB from Kernel Sistemi. Refer to the manufacturer’s manual for the basic installation, configuration, termination and addressing.
1.3 Scope of Application
The instructions describe the connection of the Solar-Log Base 2000 with the Kernel SCB from Kernel Sistemi.
Note!
The Kernel SCB from Kernel Sistemi must be connected to the Solar-Log™ via a separate RS485 interface.
1.4 Compatible Models
The following models are compatible with the Solar-Log Base 2000:
ST0HS-series:
- ST0HS 0825
- ST0HS 1225
- ST0HS 1625
- ST0HS 2425
ST0N-series:
- ST0N 0825
- ST0N 1225
- ST0N 1625
- ST0N 2425
(Status August 2023)
2. Communication Setup
The Kernel SCB is connected to either the RS485A or RS485B interface of the Solar-Log Base 2000.
The wiring is done using a
- self-made, shielded 3-wire data cable.
Connect the wires as shown in the following diagram
Important note!
The following settings must be observed:
Baud rate: 19200
Data bits: 8
Parity: No
Stop bits: 1
In addition, the SW1 DIP switch must be set to “Modbus”.
2.1 Termination and Addressing of the SCB
Please refer to the manufacturer’s instructions for the configuration, termination, addressing and wiring of the
Kernel SCB from Kernel Sistemi.
3. Solar-Log™ Installation
3.1 Configuration
To configure the Solar-Log Base 2000, you need a PC/laptop that you connect to the Solar-Log Base 2000 via a network cable or a router. Please refer to the Solar-Log Base manual for the necessary settings regarding network addresses.
Activating the Kernel SCB
- Access the web interface of the Solar-Log™.
- Activate the Kernel SCB in the Configuration | Devices | Definition | SCB menu.
Example image with activated SCB Kernel in installation mode
Additional Settings
After the SCB has been activated, adjustments need to be made to the additional settings in the following sections.
- General
- Configuration
- Analog Channels
- Digital Channels
General
The following points are under General:
- Activate SCB
- Type
- Interface
Activate SCB
The Activate SCB button activates (or deactivates) the entire SCB logic.
Type
Select Kernel SCB under Type.
Interface
Select the interface here that the SCB(s) is connected to.
Configuration
The following configuration options are available under Configuration:
- SCB Selection
- Connected
- Installation date
- Name
- Address (0-255)
- Model
- Monitoring parameters from
SCB Selection
Here the profile position of the up to 60 definable SCBs can be selected and configured.
Connected
This should be activated only after the Solar-Log Base and SCB data connection has been established and the devices communicate with each other.
In Operation
This should only be activated when the PV plant feeds into the grid.
Name
Here you enter the names of the individual SCBs. We recommend assigning unique names to ensure the correct assignments.
Address (0-255)
Enter the bus address for each SCB that was assigned to the device during the SCB configuration. We recommend starting with 1 and continuing in a consecutive and ascending order to maintain a better overview.
Model
The model of the SCB that is to be applied to this confirmation can be selected here via a pull-down menu.
Monitoring parameters from
The inverters monitoring parameters are applied by the assignment to an inverter. Several SCBs can be assigned to an inverter. This method is possible because string monitoring is not possible with central inverters and for this reason monitoring parameters are not required.
The SCB monitoring parameters can be modified in the Configuration | Notifications | Power & Failure menu.
3.2 Checking the SCB Configuration
After the SCB has been successfully installed and activated, the Solar-Log Base immediately starts to receive data from it. Go to SCB Monitor to check the installation and data. And then go to Diagnosis | Components | SCB
Monitor. Each SCB can be selected in this section from the drop-down menu in the String Overview. The measured values from all of the SCBs are displayed in the table below.
A table with the following columns is found under Measurement from (see the figure below).
- Analog no.
- Type
- Value
- Digital no.
- Type
- Value
The measurements themselves occur on a regular 15-second cycle. The time of the last measurement is displayed under Measurement from.
Type
The data type of the particular channel (e.g., analogue channel current, total power, internal temperature, total voltage etc.) is displayed.
Value
The last measured values of the particular channel are displayed here.
Example image of an SCB string overview without values
4. Displaying and Monitoring String Data
A precise graphical evaluation of the SCB string data, as well as the error and monitoring messages can be realized in the Solar-Log WEB Enerest™ (see example illustration).
Further information can be found on our homepage under Products & Solutions
Example of String Display in the Solar-Log WEB Enerest™
The copyright of these instructions remains with the manufacturer. No part of these instructions may be repro-duced in any form or processed, duplicated or distributed using electronic systems without the written consent of Solar-Log GmbH.
Non-compliance resulting in contradiction of the above-mentioned specifications shall result in obligation to provide compensation for damages.
Subject to change without notice.
Solar-Log GmbH cannot guarantee the accuracy or completeness of the information provided and expressly refuses to accept liability for any errors or omissions in such information.
All brands and trademarks contained in this manual are the sole property of the respective manufacturer, which we respect and recognize herewith. In many countries, the designation “Speedwire” is a registered trademark of SMA Solar Technology AG.
Solar-Log GmbH assumes no liability for printing errors.
Specifications
- Manufacturer: Solar-Log GmbH
- Model: Kernel SCB V1.2
- Compatibility: Solar-Log Base 2000
- Maximum Connections: Up to 60 Kernel SCBs per Solar-Log Base 2000
- Interface: RS485
Publisher:
Solar-Log GmbH
Fuhrmannstr. 9
72351 Geislingen-Binsdorf Germany
International support
Tel.: +49 (0)7428/4089-300
e-mail: info@solar-log.com Contact: https://www.solar-log.com
Italy
Technical support: +39 0471 631032
France
Technical support: +33 97 7909708
Switzerland
Technical support: +41 565 355346
United States
Technical support: +1 203 702 7189
Frequently Asked Questions (FAQ)
Q: How many Kernel SCBs can be connected to a single Solar-Log Base 2000?
A: Up to 60 Kernel SCBs can be connected to a single Solar-Log Base 2000.
Q: What is the procedure for license activation?
A: To activate a license, request a license code, and choose between automatic or manual import methods as described in the user manual.
Q: What is the warranty policy for licenses?
A: Licenses are linked to the device’s serial number. If a device is replaced after the warranty has expired, a new license must be purchased. However, during the warranty period, defective devices can have their licenses transferred to replacement devices at no additional cost.
Documents / Resources
![]() |
Solar Log SCB V1.2 String Connection Box [pdf] User Guide SCB V1.2, SCB V1.2 String Connection Box, SCB V1.2, String Connection Box, Connection Box, Box |