Yale YLBL226-PROG Libi Digital Lever Keyed 

Yale YLBL226-PROG Libi Digital Lever Keyed 

Symbol NOTE

  • Do not use any chemicals or add any lubricants when cleaning the lock, to avoid damaging the panel and coating.
  • 9V Alkaline batteries are recommended to maintain stable and prolonged power.

Operational interface

  1. Light sensor
    Proximity to wake up the interface.
  2. Number buttons
    Used to enter user codes.
    Each code must be 4 to 10 digits in length.
  3. Confirm button
    For function setup.
  4. Indicator light
    Red and green light display.
  5. Cancel button
    Numbers entered incorrectly can be deleted.
  6. Cylinder
    To be locked and unlocked with the key.
  7. Battery holder
    Uses 9V Alkaline batteries.
  8. Programming button
    Restore default setting/Programming mode.
  9. Slide
    Switch passage mode.
    Stays unlocked, allowing entry without a key or code.
  10. Battery cover
    Push it upward and outward to replace the batteries.
    Operational Interface

Operating instructions

Operation Indicator Sounds and Lights

Meaning Lights Sounds
Successful Operation Flashes Green Once 1 Beep
Successful Programming Flashes Green Twice 2 Long Beeps
Default Setting Restored Flashes Orange 3 Times 3 Long Beeps
Operation Error Flashes Red 3 Times 3 Beeps
Programming Error Flashes Red 5 Times 5 Beeps
Code Input Error 5 times/ System Lockdown Flashes Red 5 Times 5 Long Beeps
Locked Flashed Red Once 1 Long Beep
Unlocked Flashed Green Twice 2 Beeps
Low Battery Power Flashes Red 10 Times 10 Long Beeps
In Programming Mode Flashes Orange Slowly None

Programming

Symbol NOTE 

  • The programming button is located on the interior chassis below the battery holder.
  • During programming, if no button is pressed within 5 seconds, the system will time out and you will need to restart the procedure.
  • If a programming code is created, the programming button will only be used for restoring the lock to default settings.
    The code must be used to start programming mode.
  • For new installations, or when a lock is restored to default settings, you must use the programming button to start the programming mode.
 Add User Code (UC) Programming Icon 1 Icons Icon  enter UC Icons Button

NOTE : Up to 70 User Codes can be saved. User Codes should be 4 to 10 digits in length.

Delete Individual User Codes (UC) Programming Button Icons

Icon Re-enter UCIcons

2 Icon Icons enter UC Icon
Delete All User Codes (UC) Programming Button Icon 3 Icons
Add Programming Code (PC) Programming Icon 4 Icons Icon  enter PC Icons Button

NOTE :

  • The Programming Code can not be the same as any User Code and will not unlock the lock.
  • Please note once a Programing Code is enabled, the programming button is disabled and can only be used to factory reset the lock.
  • To program the lock when the Programming Code is enabled, instead of pressing the programming button, enter the Programming Code and press the confirm button to enable the Programming Code.
Set Auto-Lock Time Delay Programming Button Icon 6 Icons Icon 1-99 seconds Icons
Toggle Mute On/Off (default Off) Programming Button Icon 7 Icons
 Enable/Disable Vacation Mode Programming Icon 8Icons Button

NOTE : If enable vacation mode, all User Codes are still in the memory, but all invalid until disable vacation mode.

 Add One-time User Code Programming Icon9 Icons Icon enter Button one-time UC Icons
NOTE : Up to 5 One-time User Codes can be saved. One-time User Codes should be 4 to 10 digits in length.
Restore Default Setting

Press programming button for more than 5 seconds, and the programming is reset back to the original factory codes once you hear 3 long beeps.

NOTE : After restoring default setting, all User Codes will be deleted and all programming will be changed to factory settings.

Programming

Part of ASSA ABLOY

ASSA ABLOY New Zealand Limited, 6 Armstrong Rd, Albany Auckland 0632, New Zealand  yalehome.com/nz ©2024

Approved 2024-06-27

Programming notes

Add User Code

  • Up to 70 User Codes can be saved. User Codes should be 4 to 10 digits in length.
  • For security reasons, the first 4 digits of each User Code must be unique.
  • For example, you are unable to program a User Code 1-2-3-4-5 as well as a User Code 1-2-3-4-6.
  • Press the lock button before entering your code to light up the keypad at night.

Delete All User Codes

  • Keypad locking function will be disabled when User Codes are deleted. The lock can only be operated manually by key during this time.

Enable/Disable Programming Code

  • Optional: A Programming Code enables you to make programming changes without needing to access the programming button.
  • One Programming Code can be saved and should be 4 to 10 digits in length.
  • The Programming Code can not be the same as any User Code and will not unlock the lock.
  • To program the lock when the Programming Code is enabled, instead of pressing the programming button, enter the Programming Code and press the confirm button to enable the Programming Code.
  • Repeat the programming steps to disable the Programming Code. Please note once a Programing Code is enabled, the programming button is disabled and can only be used to factory reset the lock.

Set Auto-Lock Time Delay

  • Press the keypad number that corresponds to your time delay preference, choosing between 1 and 99 seconds.

Toggle Mute On/Off

  • LED status indicator will still function once audio is disabled. Repeat the programming steps to enable the audio.

Enable/Disable Vacation Mode

  • When vacation mode is enabled, all electronic functions will be disabled as well.
  • The door must be locked or unlocked manually with the key.
  • Repeat the programming steps to disable vacation mode.

Add One-Time Use Code

  • Up to 5 One-time User Codes can be saved. One-time User Codes should be 4 to 10 digits in length.
  • The One-Time User Code will be deleted automatically after it is used.
  • The same One-Time User Code can be created again after it’s used.

Factory Reset

  • After restoring default setting, all User Codes will be deleted and all programming will be changed to factory settings.

Slider functions – choosing a mode

Slider Functions - Choosing A Mode Auto-lock mode
Key or code is needed for entry from the outside.
Default auto-lock is 5 seconds.

Slider Functions - Choosing A Mode Passage mode
Stays unlocked, allowing entry without a key or code.

Trouble shooting

Problem Possible Cause Corrective Action
After the installation is complete and the batteries are in place, none of the buttons are responsive.
(No sound, and no backlight)
Issues with batteries or the wiring. Replace the batteries or make sure the batteries are installed correctly. Please check whether the cable from the interior lock unit is connected correctly.
The door cannot be locked. The slider is located in the function : Passage Manually switch the slider function position.
After installing the lockset and batteries, the door can’t be locked and three short beeps are emitted when you press any button. The battery doesn’t have enough energy to supply for the lock. Replace the battery.

Symbol

ASSA ABLOY Australia Pty Limited, 235 Hunting dale Rd, Oakleigh, VIC 3166 1300 LOCK UP (1300 562 587) yalehome.com/au | ABN 90 086 451 907 ©2024

Logo

Documents / Resources

Yale YLBL226-PROG Libi Digital Lever Keyed [pdf] User Guide
YLBL226-PROG, YLBL226-PROG Libi Digital Lever Keyed, Libi Digital Lever Keyed, Digital Lever Keyed, Lever Keyed, Keyed

References

Leave a comment

Your email address will not be published. Required fields are marked *