WEINTEK Win32 Easy Printer Application Instructions
WEINTEK Win32 Easy Printer

Easy Printer

This chapter explains the setup steps of Easy Printer.

Overview

Easy Printer is a Win32 application and can only run on MS Windows 7 SP1 / 8 / 10. It enables HMI to output screen hardcopies to a remote PC via Ethernet. The following explains how to use EasyPrinter.
Overview

Here are some advantages of using EasyPrinter:

  • EasyPrinter provides two modes of hardcopy output: [Print Out] and [Save to File]. Users can use either or both modes.
  • Since EasyPrinter runs on MS Windows system, it supports most of the printers available on the market.
  • Multiple HMIs can share one printer so users don’t have to prepare printers for each HMI.

Additionally, EasyPrinter can also be a backup server. Users can use Backup objects on HMI to copy history files such as Data Sampling records and Event Log to a remote PC via Ethernet. Please see the following illustration:
Overview

Using EasyPrinter as a Printer Server

Using EasyPrinter

Users can make screen hardcopies with a Function Key object. The hardcopies will be transferred to the Remote Printer Server via Ethernet and then printed out.
Setup Procedure in EasyPrinter
In EasyPrinter’s main menu, select [Options] » [Settings] and the following dialog box appears;
Setup Procedure

  1. Select [General] on the left hand side.
  2. In [Server], set [Port number of the server socket] to “8005”, [User name] to “admin” and [Password] to “111111”. (These are default values.)
  3. In [Naming Convention for HMI Folder], select [Use IP address] and enter “IP_” in the [Prefix] field.
  4.  In [Properties], select [Minimize to system tray] check box. Select [Start EasyPrinter when I
    start Windows] if necessary.

Set the print out location
Setup Procedure

  1. Select [Hardcopy] on the left hand side.
  2. Under [Output] select [Print out to] and choose a printer as the output device for screen
    hardcopies. (The printer shown in the image above is an example; please select an actual
    printer located in your network environment.)
  3. Select [Save to files in:] and browse for the directory to save the hardcopy file.
  4. Click [OK] to confirm the settings.
  5. In EasyPrinter main menu select [File] » [Enable Output] to output any incoming print
    request.

Setup Procedure in EasyBuilder Pro
The setting procedure of EasyPrinter in EasyBuilder Pro:

  1. Open a new project or an existing project in EasyBuilder Pro.
  2. In EasyBuilder Pro main menu select [Home] » [System Parameters] » [Printer/Backup Server] and select [Use Remote Printer/Backup Server] check box.
    Setup Procedure
  3. Under [Output settings] set appropriate values for left / top / right / bottom margins. (The margins are all set to 15mm in the example.)
  4. Under [Communication settings] fill in the [IP address] of the printer server according to the settings in EasyPrinter. Set [Port] to “8005”, [User name] to “admin” and [Password] to “111111”.
  5. Click [OK].
  6. In EasyBuilder Pro main menu select [Objects] » [Button], select [Function Key], select [Screen hardcopy] and set [Printer] to [MT Remote Printer/Backup Server].
    Setup Procedure
  7. Place the Function Key object in the common window (window no. 4) so that screen hardcopies can be captured anytime when needed.
  8. Compile and download the project to HMI. Press the Function Key object on the screen to make a screen hardcopy.

Note Icon Note

  • A PLC Control object can also be used to make screen hardcopies.
  • Alarm information cannot be printed via EasyPrinter.
  • EasyPrinter can only communicate with HMI via Ethernet. Please check that the HMI has appropriate network settings.

Using EasyPrinter as a Backup Sever

Using EasyPrinter

Backup objects can upload historical data and Operation Log to remote backup server.
Setup Procedure in EasyPrinter
In EasyPrinter’s main menu, select [Objects] » [Settings] and the following dialog box will
appear:
Setup Procedure

  1. Select [General] on the left hand side.
  2. Under [Server] set [Port number of the server socket] to “8005”, [User name] to “admin”
    and [Password] to “111111”. (These are default values.)
  3. Under [Naming Convention for HMI Folder] select [Use IP address] and enter “IP_” in the
    [Prefix] field.
  4. Under [Properties] select [Minimize to system tray]. Select [Start EasyPrinter when I start Windows] if necessary.

Set the backup location
Setup Procedure

  1. Select [Backup] on the left.
  2. Under [Output] click the oooooooo button to browse and select a storage directory of the incoming history files.
  3. Click [OK] to confirm the settings.
  4.  In the main menu, select [File] » [Enable Output] to backup data in the selected directory.

Setup Procedure in EasyBuilder Pro
The setup procedure of EasyPrinter in EasyBuilder Pro:

  1. Open a new project or an existing project in EasyBuilder Pro.
  2. In EasyBuilder Pro’s main menu, select [Home] » [System Parameters] » [Printer/Backup Server] and select the [Use Remote Printer/Backup Server] check box.
    Setup Procedure
  3. Under [Communication settings] fill in the [IP address] of the printer server according to the settings in EasyPrinter. Set the [Port] to “8005”, [User name] to “admin” and [Password] to “111111”. (Note: These are default values.)
  4. Click [OK].

Create a Backup object.

  1. In EasyBuilder Pro’s main menu, select [Data/History] » [Backup] and the following dialog box appears:
    Setup Procedure
  2. Under [Source] select [Historical event log] (or [RW], [RW_A] if needed.)
  3. Under [Backup position] select [Remote printer/backup server].
  4. Under [Range] select [Today] and [All] (or other options if needed.)
  5. Under [Trigger] select [Touch trigger].
  6. Click [OK].
  7. Place the [Backup] object in the common window (window no. 4), and users will be able to make backups anytime when needed.
  8. Compile and download the project to HMI. Press the Backup object on the screen to make a backup of the history data.

Note Icon Note

  • The Backup object can also be triggered by a bit address.
  • Users can arrange a Scheduler object, which turns a bit ON at the end of a week, to trigger the Backup object to automatically back up all history data.

EasyPrinter Operation Guide

The following introduces the interface and operation of EasyPrinter.
EasyPrinter Managing Window
EasyPrinter main menu is divided into 5 parts as shown in the following figure:
Setup Procedure

Area Name Description
1 Job List Lists all incoming tasks, such as screen hardcopy and backup requests
2 Download Progress Shows the download progress of incoming requests.
3 Preview Shows the preview image of the screen hardcopy task selected from [Job List].
4 Properties Shows the information about the task selected from [Job List].
5 Logger Shows the time and message information of events such as incoming request, incorrect password, etc.

Operation Guide
The following describes the function of EasyPrinter menu items.

Menu Description
File Enable Output
If selected, Easy Printer processes the tasks one by one, otherwise, Easy Printer stores the tasks in memory.
Edit Edit
Edits screen hardcopy by setting [Orientation], [Scaling] and [Margins].
Delete
Deletes the selected tasks permanently.
Select All
Selects all tasks from [Job List]
View Properties Bar
Shows or hide the Property Window. Preview Bar Shows or hide the Preview Window.
Download Bar
In [Download Progress] Window, the mode to display download progress can be set by clicking the header of the [progress] column as shown in the following figure:
Setup Procedure
Logger Bar
Easy Printer can reserve up to 10,000 messages in Message Window. If a new message comes in, the oldest message will be deleted
Options Please see the following page.

Note Icon Note

  • EasyPrinter can only reserve up to 128 MB of task data in memory. If the memory is full, any request coming in afterwards will be rejected. Users must either operate [Enable Output] or delete some tasks to make room for new tasks.
  • The backup task is not editable.
  • [Edit] is available only when a task is selected.
  • [Delete] is available when at least one task is selected.

The following is the detail for [Options] » [Settings]

  • In General Tab:
    Setup Procedure
    Setting Description
    Server Port number of the server socket
    Sets the Ethernet port number to connect the HMI. Range: 1 ~ 65535. Default: 8005.
    User name / Password
    Sets the user name and password to let only authorized HMIs send requests to EasyPrinter
    Naming Convention for HMI Folder EasyPrinter uses different folders to store files (e.g. hardcopy bitmap files, backup files) from different HMI. There are two ways to name the folders:
    Use IP address
    EasyPrinter names the folder as [Prefix] + [IP address] after the HMI at this IP address sends request.
    Use HMI name
    EasyPrinter names the folder in [Prefix] + [HMI name] after the HMI this name indicates sends request.
    Setup Procedure
    Properties Minimize to system tray
    If this check box is selected, the EasyPrinter shortcut icon will be placed in the system tray in PC. Double click the on icon in system tray to open EasyPrinter.
    Detailed message
    Select this check box to display more detailed messages about events in the message window.
    Start EasyPrinter when I start Windows
    Select this check box to automatically run EasyPrinter when Windows starts.

    . In Hardcopy Tab:
    Setup Procedure

    Setting Description
    Output Print out to
    EasyPrinter prints out the hardcopy result with the specified printers.
    Save to files in
    EasyPrinter converts the hardcopy result into a bitmap file and saves it in the specified directory. The bitmap files are found at: [Specified Path] \ [HMI Folder] \ yymmdd_hhmm.bmp For example, when a hardcopy request is given at 17:35:00, 12/Jan/2009, the bitmap file will be named “090112_1735.bmp”. And if there is another bitmap file generated within the same minute, it will be named “090112_1735_01.bmp” and so on.
  •  In Backup Tab:
    Setup Procedure
    Setting Description
    Output Backup files in: EasyPrinter stores the backup files to the specified path. The upper directory is the same: [Specified Path] \ [HMI Name] or [IP address] The lower directory:
    • For Event Log files: \ eventlog\ EL_yyyymmdd.evt l
    • For Data Sampling files: \ datalog \ [File name of the Data Sampling] \ yyyymmdd.dtl l
    • For Recipe files: \ recipe \ recipe.rcp or recipe_a.rcp l
    • For Recipe Database: \ recipe \ recipe.db l
    • For Operation Log: \ operationlog\ operationlog.db
    Convert Batch File Select [Enable] to convert the selected history file to .csv or .xls (Excel) format of Convert Batch Files.

Note Icon Note

  • System registers LW-9032 to LW-9039 can be used to specify HMI name.
  • When closing EasyPrinter, the following dialog will appear.
    Setup Procedure

Convert Batch File

EasyPrinter provides a conversion tool to convert the uploaded Data Sampling and Event Log history files to .csv files automatically. To do so, please select [Enable] under [Convert Batch File] to make EasyPrinter convert the history files. In the following illustration, the conversion is actually executed by EasyConverter. EasyPrinter simply follows the criteria in Convert Batch File and activates EasyConverter with proper arguments to achieve the conversion.
Setup Procedure

Note Icon Note

  • EasyConverter is another Win32 application that converts history data into .csv or MS Excel .xls files. Users can find it in the EasyBuilder Pro installation directory.
  • Users requesting this function must ensure EasyPrinter and EasyConverter are placed in the same directory.

The Default Value of Convert Batch File
The following is the default Convert Batch File: convert2csv.def
Listing 1. Default Convert Batch File

  1.  “dtl”, “EasyConverter /c $( Pathname)”
  2.  “evt”, “EasyConverter /c $( Pathname)”

There are two lines in the file. Each line has two arguments separated by a comma and forms a criterion of how to process a specific type of files. The first argument stands for the extension name of the file type to be processed. The second argument stands for the command to be executed in console mode. Please note that “$(Pathname)” is a key word to inform EasyPrinter to replace it with the real name of the converted backup file. For example, if a Data Sampling history file named 20090112.dtl is uploaded and stored, EasyPrinter will send out the following command to a console window:

  1. EasyConverter /c 20090112.dtl

A file named 20090112.csv is created.
The criteria of the default Convert Batch File:

  1. Convert all Data Sampling history files (.dtl) into .csv files.
  2. Convert all Event Log history files (.evt) into .csv files.

Note Icon Note

  • “$(Pathname)” in the second argument stands for the full path name of the file. In the previous case, EasyPrinter replaces it with: [Specified Path] \ [HMI Folder] \ [datalog] \ [Folder name of the Data-Sampling object] \ 20090112.dtl
  • EasyPrinter interprets the Convert Batch File in line basis, that is, each line forms a criterion.
  • Any two arguments should be separated by a comma.
  • Every argument should be put in double quotes.
  • Do not put any comma inside an argument.
  • Supported parameters for batch file: $(PathName), $(HmiName), and $(IP) which stand for file path, HMI name, and HMI IP address.
  • When [Start EasyPrinter when I start Windows] option is selected, please add in the file path where EasyConverter is placed, which is usually the EBPro installation directory in

your PC, as shown below.

  1. “dtl”, “C:\EBPro\EasyConverter /c $(Pathname)”
  2. “evt”, “C:\EBPro\EasyConverter /c $(Pathname)”

Suggestion Icon For more information, see “25 Easy Converter”.

Specialized Criteria
The specialized criterion are needed when:

  • Upload file to a specific HMI, see listing 2.
  • Identify the HMI by HMI name, see listing 3.
  • Process differently to different Data Sampling, see listing 4. (This can only be used for Data Sampling file with the file name “voltage”.) The 3rd argument (“*”) indicates this criterion accepts the Data Sampling files that meet the criterion from any HMI. Users can also change the 3rd argument to “192.168.1.26”, “192.168.1.*”, or HMI name, etc. for narrowing the range of the target HMI.

Listing 2. Specialized Criterion for the HMI IP: 192.168.1.26

  1. “dtl”, “EasyConverter /c $(Pathname)”, “192.168.1.26”

Listing 3. Specialized Criterion for HMI name: Weintek_01

  1. “dtl”, “EasyConverter /c $(Pathname)”, “Weintek_01”

Listing 4. Specialized Creterion for Data Sampling file name: Voltage

  1. “dtl”, “EasyConverter /s Voltage.lgs $(Pathname)”, “*”, “Voltage”

The Format of a Convert Batch File
The following explains the arguments in a criterion.
File Type Command
(line)
HMI IP /
Name
Condition 1
Condition 2

  • File Type
    This argument specifies the extension name of the uploaded file in this criterion.
    (e.g. “.dtl” for Data Sampling history files, “.evt” for Event Log history files)
  • Command (line)
    The command EasyPrinter sends to a console window if the uploaded file meets the
    criterion.
  • HMI IP / Name
    This argument specifies the HMI that meets the criterion.
  • Condition 1
    This argument specifies the folder name of the Data Sampling files that meet the criterion.
    This is not effective to other format of files.
  • Condition 2
    Not used (Reserved for future use).

The Order of Examining Criterion
EasyPrinter examines criterion in descending order every time a file is uploaded. Once the file meets a criterion, it stops the examination and starts over for the next file. Therefore, users should place the criterion with a wider range downward in the Convert Batch File and place the more specific criteria upward. For example:
“evt”, “EasyConverter /c $(Pathname)”
“dtl”, “EasyConverter /c $(Pathname)”
“dtl”, “EasyConverter /c $(Pathname)”, “192.168.1.26”
“dtl”, “EasyConverter /c $(Pathname)”, “my_HMI_01”
“dtl”, “EasyConverter /c $(Pathname)”, “my_HMI_02”
“dtl”, “EasyConverter /s Voltage.lgs $(Pathname)”, “*”, “Voltage”
The correct order of examination would be: (from bottom to top)
“dtl”, “EasyConverter /s Voltage.lgs $(Pathname)”, “*”, “Voltage”
“dtl”, “EasyConverter /c $(Pathname)”, “my_HMI_02”
“dtl”, “EasyConverter /c $(Pathname)”, “my_HMI_01”
“dtl”, “EasyConverter /c $(Pathname)”, “192.168.1.26”
“dtl”, “EasyConverter /c $(Pathname)”
“evt”, “EasyConverter /c $(Pathname)”