TKP-25-PP Line Paddle Wheel Flow Meter Sensor

Specifications

  • Operating Range: 0.3 to 33 ft/s, 0.1 to 10
    m/s
  • Pipe Size Range: DN08 to DN100
  • Linearity:
  • Repeatability:
  • Fluid: Water or Chemical Liquid-Viscosity
    Range: 0.5-20 centistokes
  • Flow Velocity: Up to 10 m/s
  • Low Cut: 0.3 m/s minimum
  • Operating Pressure: 150 Psi (10 Bar) @ Ambient
    Temp | Non-Shock
  • Range Ability: 10 : 1
  • Response Time: Real Time
  • Flow Total Meter: Range = 0~999999; Unit =
    Gallon or Liter or Ton (KL) Selectable

Product Usage Instructions

Safety Information

Before using the In-Line Paddle Wheel Flow Meter Sensor, ensure
you follow these safety guidelines:

  • De-pressurize and vent the system before installation or
    removal.
  • Confirm chemical compatibility before use.
  • Do not exceed maximum temperature or pressure
    specifications.
  • Always wear safety goggles or a face-shield during installation
    and service.
  • Do not alter the product construction.

Personal Protective Equipment (PPE)

When working with the sensor, ensure you wear appropriate
personal protective equipment to prevent injury.

Pressurized System Warning

Ensure that the sensor may be under pressure. Vent the system
before installation or removal to prevent equipment damage or
serious injury.

Please Ensure Full Pipe

Install the TK Series in a horizontal or vertical direction with
enough straight pipe length to avoid turbulent flow that can affect
readings.

Frequently Asked Questions (FAQ)

Q: Can the In-Line Paddle Wheel Flow Meter Sensor be used with
any type of liquid?

A: The sensor is suitable for use with water or chemical liquids
within a viscosity range of 0.5-20 centistokes.

Q: What is the maximum flow velocity supported by the
sensor?

A: The sensor can handle flow velocities of up to 10 m/s.

Q: How should I handle the sensor to avoid damage?

A: Follow the safety guidelines provided, including
de-pressurizing and venting the system before installation or
removal, and ensuring a full pipe to prevent turbulent flow.

“`

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor
Quick Start Manual

Read the user’s manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com1

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Safety Information
De-pressurize and vent system prior to installation or removal Confirm chemical compatibility before use DO NOT exceed maximum temperature or pressure specifications ALWAYS wear safety goggles or face-shield during installation and/or service DO NOT alter product construction

Warning | Caution | Danger
Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death.
Note | Technical Notes
Highlights additional information or detailed procedure.

Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during installation and service of Truflo® products.
Pressurized System Warning
Sensor may be under pressure. Take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury.

Please ensure that the Instruments are not to be subject to water hammer or pressure spikes! Always Pressure Test System with H2O Prior to Initial Start-Up
Before installation be certain the appropriate instrument has been selected considering operating pressure, full scale pressure, wetted material requirements, media compatibility, operating temperature, vibration, pulsation, desired accuracy and any other instrument component related to the service application including the potential need for protective attachments and/or special installation requirements. Failure to do so could result in equipment damage, failure and/or personal injury. Ensure only qualified personnel are permitted to install and maintain this instrument.
Pressurize System Warning
Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury.
Please Ensure Full Pipe
TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid intensified turbulent flow that can effect readings.
Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream (See Page 11)
A Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers – max 10% Particle Size – Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with compressed air this may damage the ceramic shaft and will void warranty.

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com2

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Product Description

TKP

The TK Series in-line plastic paddle wheel flow meter has been engineered to provide long-term accurate flow measurement in tough industrial applications.

The paddle wheel assembly consists of a engineered Tefzel® paddle and micro-polished zirconium ceramic rotor pin and bushings. High performance Tefzel® and Zirconium materials have been selected due to their excellent chemical and wear resistant properties.

M12 Quick Connection

Rotates 360º

True Union Design High Impact Enclosure
Bright LED Display (Flow)

New ShearPro® Design ? Contoured Flow Profile ? Reduced Turbulence = Increased Longevity ? 78% Less Drag than Old Flat Paddle Design*
*Ref: NASA “Shape Effects on Drag”
Tefzel® Paddle Wheel ? Superior Chemical and Wear Resistance vs PVDF

TK3P

Flanged Connection
316 Stainless Steel
Sanitary Connection

Zirconium Ceramic Rotor | Bushings
? Up to 15x the Wear Resistance vs Regular Ceramic ? Integral Rotor Bushings Reduce Wear
and Fatigue Stress

ShearPro® Through-Pin Design
? Eliminates Finger Spread ? No Lost Paddles ? Increased Temp. Rating ? 360° Housing Protects Rotor

vs. Flat Paddle

Finger Spread = LOST Unprotected Rotor

TKP
Thermal Plastic

vs. Competitor `A’
2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

TK3P
316 SS

Valuetesters.com

info@valuetesters.com3

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Technical Specifications

General

Operating Range

0.3 to 33 ft/s

0.1 to 10 m/s

Pipe Size Range

¼ to 4″ **

DN08 to DN100

Linearity

±0.5% of F.S @ 25°C | 77°F

Repeatability

±0.5% of F.S @ 25°C | 77°F

Fluid

Water or Chemical Liquid-Viscosity Range: .5-20 centistokes

Flow Velocity

10 m/s max.

Low Cut

0.3 m/s min.

Operating Pressure

150 Psi (10 Bar) @ Ambient Temp |Non-Shock

Range Ability

10 : 1

Response Time

Real Time

Flow Total Meter

Range = 0~999999 ; Unit = Gallon or Liter or Ton (KL) Selectable

Repeatability

Range = 0.0~999.9 ; Unit = GPM or LPM or CMH Selectable

Accuracy

± 0.5% of F.S. @ 25°C

Wetted Materials

Sensor Body

PVC (Dark) | PP (Pigmented) | PVDF (Natural) | 316 SS

O-Rings

FKM | EPDM* | FFKM*

Rotor Pin | Bushings

Zirconium Ceramic | ZrO2

Paddle | Rotor

ETFE Tefzel®

Electrical

Frequency

49 Hz per m/s nominal

15 Hz per ft/s nominal

Supply Voltage

9 to 30 VDC ±10% regulated

Supply Current

<1.5 mA @ 3.3 to 6 VDC

<20 mA @ 6 to 24 VDC

Max. Temperature/Pressure Rating ­ Standard and Integral Sensor | Non-Shock

PVC

180 Psi @ 68°F | 40 Psi @ 140°F

12.5 Bar @ 20°C | 2.7 Bar @ 60°C

PP

180 Psi @ 68°F | 40 Psi @ 190°F

12.5 Bar @ 20°C | 2.7 Bar @ 88°C

PVDF

200 Psi @ 68°F | 40 Psi @ 240°F

14 Bar @ 20°C | 2.7 Bar @ 115°C

316 SS

200 Psi @ 180°F | 40 Psi @ 300°F

14 Bar @ 82°C | 2.7 Bar @ 148°C

Operating Temperature

PVC PP PVDF 316 SS

32°F to 140°F -4°F to 190°F -40°F to 240°F -40°F to 300°F

0°C to 60°C -20°C to 88°C -40°C to 115°C -40°C to 148°C

Outputs

NPN Pulse | RS485

Display

LED | Flow Rate + Flow Totalizer

Standards and Approvals

UL | CE | FCC | RoHS Compliant See Temperature and Pressure Graphs for more information

*Optional ** ¼” – ” SS Only

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com4

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Exploded View ­ TKP Series
1 2

7

5

6

8

3 4

1

PC Cover

2

TKP Controller

3

Rotor Assembly

4

Body – PVC | PP | PVDF

5

Rotor Pin

6

Rotor Bushing

7

ShearPro® Paddle Wheel

8

Reinforced Inserts

2″

1/2″ Same Controller | Rotor Assembly for All Sizes

Wiring Diagram

TKP Flow Meter Output Circuit

Brown Black White Yellow Grey Blue

+VDC

Load

Pulse (NPN)

Load

Pulse (NPN)

+
RS-485 Special Option

0V

Brown +10 – 30 VDC

Blue -VDC

White

Pulse Output NPN

Yellow RS485A Grey RS485B Black Pulse Output NPN

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com5

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Programming

STEPS

1

Home Screen

+F

3 Sec.

2

Password

3

Units of Flow

4

K Factor

Select/Save/Continue

F

Move Selection Left

DISPLAY

OPERATION

Home Screen

Change Digit Value

Factory Default: Lk = 10 Otherwise meter will enter Lockout Mode* Press / to change Press to save
Range: 0 ~ 2 Ut.0 = Liter | Ut.1 = Gallon (Factory Default) | Ut.2 = Kiloliters

Enter K Factor Value Refer to Page 9 for K-Factor Values

Totalizer Reset

STEPS

1

Home Screen

+

3 Sec.

2

Totalizer Reset

DISPLAY

Home Screen

OPERATION

Totalizer Value will Reset to Zero

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com6

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Setting Output Limits

STEPS

1

Home Screen

Select/Save/Continue

F

Move Selection Left

DISPLAY

OPERATION

Home Screen

Change Digit Value
Current Value (CV) Set Value (SV)

2 Flow Rate Pulse Relay Output

Flow Rate Pulse Relay Output (OP1) Limit CV : Current Flow Rate Value SV : Flow Rate Pulse Relay Output Set Value Note: Refer Relay Mode Selection (Pg 6)

3 Totalizer Pulse Relay Output

Totalizer Pulse Relay Output (OP2) Limit CV : Current Totalizer Value SV : Totalizer Pulse Relay Output Set Value Note: Refer Pulse Output Control Settings (Pg 8)

Wiring

Flow Rate Pulse Relay Output

Set “Con F/E/r/c” in Pulse Output Control*

Wire Color Brown White Blue

Description + 10~30VDC Flow Rate Pulse Output (OP1)
-VDC

* SSR – Solid State Relay

Totalizer Pulse Relay Output

Set “Con n” in Pulse Output Control*

Wire Color Brown Black Blue

Description + 10~30VDC Totalizer Pulse Output (OP2)
-VDC

Output to Flow Display

Set “Con F” in Pulse Output Control*

Wire Color Brown Black Blue

Description + 10~30VDC Paddle Pulse
-VDC

One Pulse/Gallon Output

Set “Con E” in Pulse Output Control*

Wire Color Brown Black Blue

Description + 10~30VDC Pulse Output
-VDC

One Pulse/Gal + Flow Rate Pulse Relay Output

Set “Con E” in Pulse Output Control*

Wire Color Brown Black White Blue

Description + 10~30VDC Pulse Output (1 Pulse/Gal) SSR (Flow Rate)
-VDC

* Refer Pulse Control Programmming, Page 8
Note: Refer to ‘Relay Mode Selection’ on Page 8 to configure the relay output as needed.

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com7

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Pulse Control Programming

Select/Save/Continue

F

Move Selection Left

STEPS

DISPLAY

1

Home Screen

3 Sec.

Home Screen

OPERATION

Change Digit Value

2

Pulse Output Control

3 OP2 Auto Reset Time Delay

Con = n : OP2 Manual Reset (When Totalizer = Set Value (SV)) Con = c | r : OP2 Auto Reset after (t 1) Secs Con = E : One Pulse/Gal (Default) Con = F : Paddle Pulse — Frequency Max 5 KHz (For TVF)
Range: 0 ~ 999.99 Secs (Displayed only when Con r | Con c is selected)

4

Relay Setting

5

Hysteresis

6 OP1 Power On Time Delay

Range: 0 ~ 3 ALt = 0 (Default) Refer to Relay Mode Selection
Range: 0.1 ~ 999.9 HyS = 1 (Default) (Hysteresis is a buffer around the Programmed Set Point)
Range: 0 ~ 9999 Secs t2 = 20 Sec (Default)

7

MODBUS Configuration

Communication Configuration 8n1 : 8 bit Non Parity (Default) 8o1 : 8 bit Odd Parity 8E1 : 8 bit Even Parity

8n2 : 8 bit Non Parity 7o1 : 7 bit Odd Parity 7E1 : 7 bit Even Parity

Relay Mode Selection

ALt No.

Description

ALt = 0 CV SV — Relay ON | CV < [SV – Hys] — Relay OFF

ALt = 1 CV SV — Relay ON | CV > [SV + Hys] — Relay OFF

ALt = 2 [SV + Hys] CV [SV – Hys] — Relay ON : CV > [SV + Hys] or CV < [SV – HyS] — Relay OFF

ALt = 3 [SV + Hys] CV [SV – Hys] — Relay OFF: CV > [SV + Hys] or CV < [SV – HyS] — Relay ON

Hys = Hysteresis — Acts like a buffer ± around (OP1) pulse output

CV: Current Value (Flow Rate) | SV = Set Value

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com8

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor

Temperature | Pressure Graphs | Non-Shock
Note: The Pressure/Temperature graphs are specifically for the Truflo® Flow Meter Sensors. During system design the specifications of all components must be considered.

= PVC

Bar Psi 15.2 220

13.8 200

12.4 180

11.0 160

9.7 140

8.3 120

6.9 100

5.5 80

4.1 60

2.8 40

1.4 20

00

ºF 68

104

ºC 20

40

= PP

140

175

60

80

= PVDF

212

248

100

120

K-Factor

Size ¼” ” ½” ¾” 1″ 1½” 2″ 3″ 4″

LPM 547 300 127.6 81.8 55.1 18.8 10.2 4.7 2.1

GPM 2079 1140 484.9 310.8 209.4 71.4 38.8
18 8

K-Factor is Pre-Programmed

Model Selection

Min/Max Flow Rates

Pipe Size (O.D.)

DN08 DN10 DN15 DN20 DN25 DN40 DN50 DN65 DN80 DN100

(¼”) (“) (½”) (¾”) (1″) (1½”) (2″) (2½”) (3″) (4″)

LPM | GPM 0.3m/s min.
0.6 | 0.16 1.8 | 0.48 3.5 | 1.0 5.0 | 1.5 9.0 | 2.5 25.0 | 6.5 40.0 | 10.5 60.0 | 16.0 90.0 | 24.0 125.0 | 33.0

LPM | GPM 10m/s max.
12 | 3 50 | 13 120 | 32 170 | 45 300 | 79 850 | 225 1350 | 357 1850 | 357 2800 | 739 4350 | 1149

SS Only SS Only

Size ½” ¾” 1″ 1 ½” 2″ 3″ 4″

PVC
End Connections Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Flanged Flanged

Size ½” ¾” 1″ 1 ½” 2″ 3″ 4″

PP
End Connections NPT NPT NPT NPT NPT
Flanged Flanged

Part Number TKP-15-P TKP-20-P TKP-25-P TKP-40-P TKP-50-P TKP-80-P TKP-100-P
Part Number TKP-15-PP TKP-20-PP TKP-25-PP TKP-40-PP TKP-50-PP TKP-80-PP TKP-100-PP

Size ½” ¾” 1″ 1 ½” 2″

PVDF
End Connections NPT NPT NPT NPT NPT

Part Number TKP-15-PF TKP-20-PF TKP-25-PF TKP-40-PF TKP-50-PF

Size ¼” ” ½” ¾” 1″ 1 ½” 2″ 3″ 4″

316 SS
End Connections NPT NPT NPT NPT NPT NPT NPT NPT NPT

Part Number TK3P-08-SS TK3P-10-SS TK3P-15-SS TK3P-20-SS TK3P-25-SS TK3P-40-SS TK3P-50-SS TK3P-80-SS TK3P-100-SS

PVC Socket Ends (Std) Note:
PP/PVDF NPT Ends (Std)
Add 2nd Suffix (seals): FKM (std, no suffix required) -E EPDM Seals -K FFKM | Kalrez® Seals
Add 1st Suffix (end connection): -T NPT End Connectors (on PVC) -B Butt Fusion End Connections for PP or PVDF -F Flange ANSI 150lb – Consult Factory

316SS PC

PVC

PP PVDF

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com9

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor
Dimensions
L 2.2

Pipe Size L (inch) D (inch) C (inch)

½” DN (15) ¾” DN (20) 1″ DN (25) 1½” DN (40) 2″ DN (50)

5.48 6.12 6.76 7.66 8.40

1.07 1.36 1.68 2.33 2.86

1.61 2.08 2.36 3.26 4.33

1.8

1.85

C

Procedure to Rotate Display

1

Flow Meter & Transmitter

OP2

FTM

OP1

GPM

2

D

Flow Meter & Transmitter

OP2

FTM

OP1

GPM

C
3

OP2

FTM

OP1

GPM

Using an allen key loosen the 2 screws located on either side of the display.

Pull the Screws | Do Not Remove!

4

5

6

Lift the Display.

Flow Meter & Transmitter OP2 FTM OP1 GPM F
Flow Meter & Transmitter OP2 FTM OP1 GPM F
Flow Meter & Transmitter OP2 FTM OP1 GPM F

Rotate Display 90°.
2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Lower Display.

Tighten Allen Screws | Snug Tight Do Not Over-Tighten!

Valuetesters.com

info@valuetesters.com10

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor
Installation Position

10x

3x

CORRECT

INCORRECT

10x

CORRECT

3x

CORRECT

INCORRECT

10x

3x

INCORRECT

CORRECT

10x

3x

INCORRECT

Please Ensure Full Pipe
TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid turbulence that can effect readings.
Note: Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream.
A Plastic Basket Strainer, Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers – max 10% Particle Size – Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with Compressed Air this may damage the ceramic shaft and will Void Warranty.

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com11

Truflo® — TKP | TK3P Series (V1)
In-Line Paddle Wheel Flow Meter Sensor
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.
Limitations
This warranty does not apply to products which: 1. are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures
outlined above; 2. have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3. have been modified or altered; 4. anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5. have been involved in accidents or natural disasters; or 6. are damaged during return shipment to Icon Process Controls Ltd
Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1. there is evidence of a potentially hazardous material present with the product; 2. or the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd
has dutifully requested disposition.
This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.

by

2F4i-n05d97Qu©aIclointyProPcresosdCounctrtosls LOtdn. line at:

Valuetesters.com

info@valuetesters.com12

Documents / Resources

valuetesters TKP-25-PP Line Paddle Wheel Flow Meter Sensor [pdf] User Guide
TKP-25-PP Line Paddle Wheel Flow Meter Sensor, TKP-25-PP, Line Paddle Wheel Flow Meter Sensor, Wheel Flow Meter Sensor, Flow Meter Sensor, Meter Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *