SST Automation OPGateway Industrial Communication Software User Manual

OPGateway Industrial Communication Software

Product Information

Specifications

  • Product Name: Industrial Communication Software OPGateway
  • Version: V2.1
  • Manufacturer: SST Automation
  • Contact Email: support@sstautomation.com
  • Website: www.sstautomation.com

Product Usage Instructions

1. Installation and Activation

1.1 Installation

Double-click the installation file (.exe file) and follow the
on-screen instructions for a step-by-step installation process.

1.2 Activation

If the software is not activated:

  1. Activate: Contact technical support to obtain the activation
    file. Import the file for activation.
  2. Trial: Click the Trial button for a 2-hour trial period. Save
    your project files before the trial expires.

2. Software User Manual

2.1 Navigating the Configuration

The Configuration is divided into four panes:

  • Server View: Displays all OPC Servers on the
    local computer.
  • Group&MQTT View: Allows operations like
    creating, modifying, and exporting CSV for Groups and MQTT.
  • Link View: Supports operations like creating,
    modifying, and copying Links.
  • Event Log View: Displays user operation logs
    and allows saving them.

You can also check for news updates by clicking on News.

2.2 What is OPC Groups

OPGateway facilitates Tag linking between single or multiple
local OPC servers, enabling data transfer across servers by adding
Groups and assigning Link Items.

2.2.1 Group Properties

The parameter descriptions include:

  • Name: Unique name for the Group.
  • Description: Set a description for the
    Group.
  • Scan Rate: Update rate for server data with a
    minimum value of 10ms.
  • Range: 10ms

Frequently Asked Questions (FAQ)

Q: How can I obtain the activation file?

A: Contact a technical support engineer to obtain the activation
file.

Q: What happens after the trial period expires?

A: The software will automatically exit. Make sure to save your
project files before the trial ends.

Q: What is the purpose of OPC Groups in OPGateway?

A: OPC Groups enable Tag linking functionality between local OPC
servers for data transfer.

“`

Industrial Communication Software OPGateway User Manual
V2.1
SST Automation
Email: support@sstautomation.com www.sstautomation.com

Table of Contents
1 Overview …………………………………………………………………………………………………………………………2 1.1 Software function ……………………………………………………………………………………………………2 1.2 Supported Operating Systems …………………………………………………………………………………. 2 1.3 Supported Interfaces ………………………………………………………………………………………………. 2 1.4 Revision History ……………………………………………………………………………………………………. 2
2 Installation and Activation …………………………………………………………………………………………………3 2.1 Installation ……………………………………………………………………………………………………………. 3 2.2 Activation ………………………………………………………………………………………………………………3
3 Software User Manual ……………………………………………………………………………………………………… 4 3.1 Navigating the Configuration ………………………………………………………………………………….. 4 3.2 What is the OPC Groups ………………………………………………………………………………………… 5 3.2.1 Group Properties …………………………………………………………………………………………..5 3.2.2 Link Item Properties …………………………………………………………………………………….. 6 3.3 What is the OPC DA to MQTT ……………………………………………………………………………….. 8 3.3.1 MQTT Properties ………………………………………………………………………………………….8 3.3.2 Topic Properties …………………………………………………………………………………………. 11 3.3.3 MQTT Item Properties ……………………………………………………………………………….. 12 3.4 How Do I…Configure OPC Groups ……………………………………………………………………….. 15 3.4.1 Starting a New Project …………………………………………………………………………………15 3.4.2 Adding a Group …………………………………………………………………………………………. 15 3.4.3 Adding a Link ……………………………………………………………………………………………. 17 3.4.4 Saving the Project ……………………………………………………………………………………….21 3.5 How Do I…Configure OPC DA to MQTT ……………………………………………………………….23 3.5.1 Adding a MQTT ………………………………………………………………………………………… 23 3.5.2 Adding a Topic ……………………………………………………………………………………………25 3.5.3 Adding a Link ……………………………………………………………………………………………. 26 3.5.4 Saving the Project ……………………………………………………………………………………….30 3.6 How Do I… Import and Export Links Using a CSV File ……………………………………………32 3.7 Apply/Start/Stop/Restart Service …………………………………………………………………………….34 3.8 Check for updates ………………………………………………………………………………………………… 36
Appendix ………………………………………………………………………………………………………………………….37 KEPServerEX Software Project File Description …………………………………………………………..37

www.SSTAutomation.com

1

1 Overview

1.1 Software function
OPGateway is software that provides data linking between OPC systems, serving as a bridge for communication between multiple OPC servers or between MQTT and OPC DA servers. OPGateway can function as both a client and a server. As an OPC client, users can collect data from one or more OPC servers via OPGateway. As an OPC server, OPGateway can gather, organize, and link data from other OPC servers and then provide the data to OPC clients. Additionally, OPGateway supports the direct transmission of real-time industrial data to enterprise device clouds, big data analysis platforms, and databases via interfaces such as MQTT and Native.
1.2 Supported Operating Systems
· Windows 11 · Windows 10 · Windows Server 2022 · Windows Server 2019 · Windows Server 2016 · Windows Server 2012 R2 and 2012
1.3 Supported Interfaces
· OPC DA 3.0 · OPC DA 2.0 · MQTT 3.1 · MQTT 3.1.1 · MQTT 5.0 · Native
1.4 Revision History

Date 2024-12-30

Revision V2.1

First Release

Description

www.SSTAutomation.com

2

2 Installation and Activation
2.1 Installation
Double -click the installation file (.exe file) and gradually install according to the software prompts. To install the software, double-click the installation file (.exe), and follow the on-screen instructions step by step.
2.2 Activation
If the software is not activated, the “Software activation” prompt will pop up:
(1) Activate: After purchasing the software, please contact a technical support engineer to obtain the activation file. Click the “Import” button, and the activation will be completed after the file is imported.
(2) Trial: If activation is not required, you can click the “Trial” button to enter the main interface of the software. The trial period lasts for 2 hours (there will be a countdown reminder on the software interface).After the trial period expires, the software will automatically exit. Please make sure to save your project files in time.

www.SSTAutomation.com

3

3 Software User Manual
3.1 Navigating the Configuration
The application Configuration is divided into four panes: the Server View, the Group&MQTT View, the Link View, and the Event Log View.

Server View:It can display all OPC Servers on the local computer. Group&MQTT View:It allows operations such as creating, modifying, deleting, importing
CSV, and exporting CSV for Group and MQTT. Link View:It allows operations such as creating, modifying, deleting, copying, and pasting
Links. Event Log View: Information displays the user’s operation log and allows the log to be saved.
You can also click on “News” to get the latest news.

www.SSTAutomation.com

4

3.2 What is the OPC Groups
OPGateway provides Tag linking functionality between single or multiple local OPC servers, enabling data transfer between Tags across multiple servers. Users can add multiple Groups and assign Link Items to them to achieve the linking functionality.
3.2.1 Group Properties

The parameter descriptions are as follows: Name: The name of the Group, which must be unique. Description: Set a description for the Group name. Scan Rate: Set the update rate for server data, with a minimum value of 10ms. Range: 10ms
to 600000ms. Connection Timeout: Effective when “Automatic Reconnection” is enabled. Range: 1 to
3600 seconds. Automatic Reconnection: Enable this option to allow OPGateway to automatically
reconnect to an OPC Server with an established connection. The interval for automatic reconnection can be configured.

www.SSTAutomation.com

5

3.2.2 Link Item Properties
The Link Item properties interface includes the following sections: General,Input,and Output.
1. General Interface:

The parameter descriptions are as follows: Name: Set the name for this Link. Description: Set the description for the Link name.
2. Input Interface:

The parameter descriptions are as follows: Machine name: Currently, only OPC servers on the local computer are supported. Server: The name of the OPC server to be accessed. Access Path: Some OPC servers require this parameter to help determine the Item ID. Refer
to the actual OPC server to determine whether this parameter needs to be filled in. Item ID: The data source referenced by the OPC server. If the OPC server supports tag
browsing, you can click the “…” button to open the tag browsing dialog. Double-clicking a tag will set the Item ID, and the dialog will automatically close, with the Item ID being filled

www.SSTAutomation.com

6

in automatically. Data Type: Set the data type for communication with the OPC server. Supported data types
are defined as follows:

Native Boolean Char Byte Short Word Long DWord Float Double String

Default as determined by the OPC server Single bit Signed 8-bit value Unsigned 8-bit value Signed 16-bit value Unsigned 16-bit value Signed 32-bit value Unsigned 32-bit value Single precision floating point value. (32-bits) Double precision floating point value (64-bits) Zero terminated character array

*Except for Boolean and String types, all the above data types can be selected as arrays.
3. Output Interface:

The parameter description is the same as Input.

www.SSTAutomation.com

7

3.3 What is the OPC DA to MQTT
OPGateway can act as an OPC client to collect data from one or more OPC servers. It transmits the data to the enterprise’s device cloud, big data analysis platform, or database through interfaces such as MQTT, Native, etc. OPGateway needs to create MQTT, Topic, and Link for related configurations.
3.3.1 MQTT Properties

The parameter descriptions are as follows:
Connection Properties:
MQTT Name: The username and identity key for connecting to the general MQTT platform, which can be obtained from the cloud platform you wish to connect to.
Username,Password: Set the username and password for authentication. MQTT Broker Address: The IP or URL address of the cloud platform to connect to. MQTT Broker Port: The port number of the cloud platform to connect to. Publish Type: There are two options: Interval: Sends changed data to the cloud when data changes. Change of value: Sends data to the cloud at a configured interval, regardless of whether the data has changed. Scan Rate(ms): Effective when the data transmission mechanism is set to “Interval”
This sets the time interval for sending data, with a range of 10­600000ms. The default setting is 1000ms.

www.SSTAutomation.com

8

Keep Alive Interval(s): The interval between sending successive Keep Alive packets after OPGateway sends a Keep Alive and receives a correct reply. The range is 10­99999990s, with a default setting of 60s.
MQTT Version: The MQTT protocol version. Currently, versions V3.1, V3.1.1, and V5.0 are supported. Users can select the version according to their needs.
Clean Session: The default is checked. Checked: If the OPGateway service disconnects, a new connection will be created, and data
from before the disconnection will not be retained. Unchecked: When the OPGateway service reconnects, it can continue to receive messages
published to the topics it subscribes to during the offline period. Auto Reconnect: The auto-reconnect feature. The default is checked. If the MQTT connection times out and disconnects, it will automatically attempt to reconnect. Enabled: Whether to enable this MQTT connection. The default is checked, enabling this MQTT connection.
Advanced:
Client ID: The unique identifier for the MQTT client when connecting to the server. Each client connection to major cloud platforms must have a unique Client ID. If there are no special requirements, it is recommended to click the “Auto new Client ID” button to randomly generate a Client ID. The parameter can be set with a character length of 1­128.
Custom Message Format: The default is off, meaning custom data formatting is disabled, and data will be transmitted in the default format. The default data transmission format is: { “Tag4_K”:12 }
Edit Message Format: Effective when “Custom Send Data Format” is set to “On.” Users can edit the data transmission format, and the device will automatically convert data into the corresponding format before sending it. Click the “Edit” button to open the settings window as shown below:

www.SSTAutomation.com

9

1 Example Format Description: { “timestamp”: |TIMESTAMP|, “values”: { |#each VALUES| “id”: “|TAGNAME|”, “name”: “|PROPERTIESNAME|”, “v”: |VALUE|, “q”: |QUALITY|, “t”: |OPCTIME||#unless @last|,|/unless| |/each| } }
|TAGNAME|: The full path of the Tag.
|PROPERTIESNAME|: The name of the property.
|VALUE|: The value of the tag.
|QUALITY|: The quality of the tag.
|OPCTIME|: The timestamp when the tag value was updated.
|TIMESTAMP|: The time when the tag value was read.
2 Click “Check JSON” to validate the JSON format. 3 Click “Preview” to view the message preview, as shown below:

www.SSTAutomation.com

10

SSL/TLS: By default, SSL/TLS is disabled. When enabled, it allows secure MQTT connections to the cloud platform, ensuring safe data transmission.
3.3.2 Topic Properties

The parameter descriptions are as follows:
Topic Name: Set the name of this Topic. It can be customized, but should not be duplicated. It is used to filter or organize the data published/subscribed on the broker.
Topic Type: Set the Topic type. There are three options available: Publish, Subscribe, and Publish and Subscribe. Publish: OPC data is sent to the MQTT platform. Subscribe: MQTT data is sent to the OPC side.
QoS: The default setting is 0. There are three options available: 0, 1, and 2. QoS 0: For OPC, data will be sent only once, regardless of whether MQTT receives it. Suitable for less critical data.

www.SSTAutomation.com

11

QoS 1: For OPC, an acknowledgment (ack) will be sent to ensure that data reaches the client or server. However, it cannot guarantee that the data is sent only once. If the ack is not received, the data will be resent, up to a maximum of 3 times. QoS 2: For OPC, a complex four-step handshake is used to ensure secure data delivery to the client or server, ensuring that messages are neither lost nor duplicated. Retain: Checked: Ensures that subscribers can receive messages that were published earlier, addressing subscription delays and providing immediate message delivery. Unchecked: New clients subscribing to this Topic will not receive retained messages.
3.3.3 MQTT Item Properties
The MQTT Item properties interface consists of the following sections: General, MQTT End, and Output.
1. General Interface

The parameter descriptions are as follows: Name: Set the name of the Link. Description: Set the description for the Link name.
2. MQTT End Interface

www.SSTAutomation.com

12

The parameter descriptions are as follows:
Tag Name: Set the name of the MQTT side tag. State: Determines whether the current point is enabled. Byte Swap: Currently only supports “No”, meaning the data is transmitted normally. Scale: Default is 1.000. The range is from 0.001 to 1000. Example: Set the scaling factor to
0.001, with an input value of 123000. The output value will display as 123000 x 0.001 = 123. NwFault: Currently only supports “Hold”.
Hold: When a network failure occurs at the input, the output will retain the last correctly received data.
3. Output Interface

The parameter descriptions are as follows: Machine name: Currently, only OPC servers on the local computer are supported. Server: The name of the OPC server to be accessed. Access Path: Some OPC servers require this parameter to help determine the Item ID. Refer
to the actual OPC server to determine whether this parameter needs to be filled in. Item ID: The data source referenced by the OPC server. If the OPC server supports tag
browsing, you can click the “…” button to open the tag browsing dialog. Double-clicking a tag will set the Item ID, and the dialog will automatically close, with the Item ID being filled

www.SSTAutomation.com

13

in automatically. Data Type: Set the data type for communication with the OPC server. Supported data types
are defined as follows:

Native Boolean Char Byte Short Word Long DWord Float Double String

Default as determined by the OPC server Single bit Signed 8-bit value Unsigned 8-bit value Signed 16-bit value Unsigned 16-bit value Signed 32-bit value Unsigned 32-bit value Single precision floating point value. (32-bits) Double precision floating point value (64-bits) Zero terminated character array

*Except for Boolean and String types, all the above data types can be selected as arrays.

www.SSTAutomation.com

14

3.4 How Do I…Configure OPC Groups
OPGateway can achieve data transfer between Tags in an OPC Server by creating Groups and Items. Taking the local OPC Server (KEPServerEX software) as an example, the process of transferring data between two Tags is explained as follows.
3.4.1 Starting a New Project
To start, open OPGateway by double-clicking the desktop icon. Alternatively, select OPGateway from the Windows Start menu. Click the menu bar [File-> New] button, or toolbar [New] button to create a new project file:

3.4.2 Adding a Group
1. Below OPC Groups, click [Click to add an OPC Group] button to create a new group.
The Group can also be created in the following ways (1) Right-click on OPC Groups, open the context menu, and select [New Group] to configure.
(2) Right-click on the added Group, open the context menu, and select [New Group] to configure.

www.SSTAutomation.com

15

You can also click the [Delete Group] button to delete the Group. You can also click the [Import CSV…] or [Export CSV…] button to import/export the Link Items under the Group using a CSV file.
(3) Click the [Edit -> New Group] button in the menu bar to configure.

You can also click the [Delete Group] button to delete the Group.
(4) Click the [New Group] button on the toolbar to configure.
You can also click the [Delete] button to delete the Group.
2. Open the Group Properties interface: You can set the name and other parameters of the Group. If there are no special requirements, the default settings can be used. To modify the Group configuration, double-click on the Group to open the properties interface.

www.SSTAutomation.com

16

For more information, please refer to”3.2.1 Group Properties”. 3. Click ‘OK’ to complete the configuration.
3.4.3 Adding a Link
Before creating a Link, ensure that the local OPC Server is installed and the Tags for input and output have been created. The OPC Server used in this document is the KEPServerEX software, which is installed locally. Tag1_R and Tag2_K, have been created using the Simulator driver. 1. On the blank area on the right side, click [Click to add a link] to create a new link.

The Link can also be created in the following ways (1) Right-click on the blank area on the right side, open the context menu, and select [New Link] to configure.

www.SSTAutomation.com

17

(2) Right-click on the added Link, open the context menu, and select [New Link] to configure.
You can also click other buttons to Delete, Copy, or Paste the Link. (3) Click the [Edit -> New Link] button in the menu bar to configure.

You can also click other buttons to Delete, Copy, or Paste the Link. (4) Click the [New Link] button on the toolbar to configure.
You can also click the [Delete] button to delete the Link. 2. Open the Link Properties interface: The General interface allows you to set the Link’s name and description. Set them according to your needs. To modify a Link, double-click on the Link to open the properties interface.

www.SSTAutomation.com

18

3. Next, open the Input tab: In the example below, the machine name is “Local Machine” and the server is Kepware.KEPServerEX.V6.

Click the “…” button to open the following interface:

Double-click Tag1_R to complete the addition:

www.SSTAutomation.com

19

Data Type: Select the default setting, Native. For more information, please refer to”3.2.2 Link Item Properties”.
4. Next, open the Output tab:

Click the “…” button to open the following interface:

Double-click Tag2_K to complete the addition:

www.SSTAutomation.com

20

Data Type: Select the default setting, Native. For more information, please refer to”3.2.2 Link Item Properties”. 5. Click ‘OK’ to complete the configuration.
3.4.4 Saving the Project
1. After completing the project file setup, click the [File -> Save] button in the menu bar or the [Save] button on the toolbar to save the file.

2. Open the save window, enter the project file name, and click the Save button to save.

3. Click the [Service -> Apply] button in the menu bar to start the service.

www.SSTAutomation.com

21

A progress bar will pop up. Once the progress bar completes, the prompt will automatically close, and the service will start running.
The Link will appear as follows: 4. Open the KEPServerEX software interface, click the QC button on the toolbar, and check the data transmission results.
The data from Tag1_R has been transferred to Tag2_K:

www.SSTAutomation.com

22

3.5 How Do I…Configure OPC DA to MQTT
An example is given to explain the configuration process for publishing and subscribing between the local OPC Server (KEPServerEX) and the MQTT Broker using OPGateway.
3.5.1 Adding a MQTT
1. Below OPC DA to MQTT, click [Click to add a MQTT connection] button to create a new MQTT.
The MQTT can also be created in the following ways (1) Right-click on OPC DA to MQTT, open the context menu, and select [New MQTT] to configure.
(2) Right-click on the added MQTT, open the context menu, and select [New MQTT] to configure.

You can also click other buttons to delete or disable the MQTT. Click the [Add Topic] button to create a Topic under this MQTT.
(3) Click the [Edit -> New MQTT] button in the menu bar to configure

www.SSTAutomation.com

23

You can also click the [Delete MQTT] button to delete the MQTT.
(4) Click the [New MQTT] button on the toolbar to configure.
You can also click the [Delete] button to delete the MQTT.
2. Open the MQTT Properties interface In this interface, configure the MQTT client by filling in the MQTT Broker’s username, password, Broker address, and port. Click ‘Create new Client ID’ to fill in the ‘Client ID,’ and leave the other settings as default. To modify the MQTT configuration, double-click on the MQTT to open the properties interface.

For more information, please refer to”3.3.1 MQTT Properties”. 3. Click ‘OK’ to complete the configuration.

www.SSTAutomation.com

24

3.5.2 Adding a Topic
1. Under the created MQTT, click [Click to add a Topic] to create a new Topic.
The Topic can also be operated as follows: (1) Right-click on the added MQTT, open the context menu, and select [Add Topic] to configure.
(2) Right-click on the added Topic to open the context menu, where you can delete or disable the Topic.

You can also click the [Import CSV…] or [Export CSV…] button to import/export the Link Items under the Topic using a CSV file, and click [New link] to create a new link.
(3) Select the added Topic and click the [Disable] button on the toolbar to disable the Topic.

www.SSTAutomation.com

25

2. Open the Topic Properties interface: (1) Add a publish Topic: Topic0

For more information, please refer to”3.3.2 Topic Properties”. (2) Add a subscribe Topic: Topic1

For more information, please refer to”3.3.2 Topic Properties”. 3. Topic creation complete:

3.5.3 Adding a Link
Before creating a Link, ensure that the local OPC Server is installed and the Tags for input and output have been created. The OPC Server used in this document is the KEPServerEX software, which is installed locally. Tag3_R and Tag4_K, have been created using the Simulator driver.

www.SSTAutomation.com

26

1. Select Topic0 (Publish Topic): 1On the blank area on the right side, click [Click to add a link] to create a new link.
The Link can also be created in the following ways 1 Right-click on the blank area on the right side, open the context menu, and select [New
Link] to configure.
2 Right-click on the added Link, open the context menu, and select [New Link] to configure.
You can also click other buttons to Delete,Disable, Copy, or Paste the Link. 3 Click the [Edit -> New Link] button in the menu bar to configure.

www.SSTAutomation.com

27

You can also click other buttons to Delete, Copy, or Paste the Link. 4 Click the [New Link] button on the toolbar to configure
You can also click the [Delete] button to delete the Link. 2The ‘Select Item ID’ interface pops up, and select Tag3_R in KEPServerEX to be used for publishing:

Click the ‘OK’ button to complete the addition of the Link, as shown below:
3To modify the Link settings, double-click the Link to open the Link properties interface as shown below: You can configure the parameters on the General, MQTT End, and Output tabs.

For more information, please refer to”3.3.3 MQTT ItemProperties”. 2. Select Topic1(Subscribe Topic):

www.SSTAutomation.com

28

1On the blank area on the right side, click [Click to add a link] to create a new link.
2The ‘Select Item ID’ interface pops up, and select Tag4_K in KEPServerEX to be used for publishing:

Click the ‘OK’ button to complete the addition of the Link, as shown below:
3To modify the Link settings, double-click the Link to open the Link properties interface as shown below: You can configure the parameters on the General, MQTT End, and Output tabs.

For more information, please refer to”3.3.3 MQTT ItemProperties”.

www.SSTAutomation.com

29

3.5.4 Saving the Project
1. After completing the project file setup, click the [File -> Save] button in the menu bar or the [Save] button on the toolbar to save the file.

2. Open the save window, enter the project file name, and click the Save button to save.

3. Click the [Service -> Apply] button in the menu bar to start the service.
A progress bar will pop up. Once the progress bar completes, the prompt will automatically close, and the service will start running.

4. Use MQTT.fx software to illustrate the data exchange process with KEPServerEX: (1) Open the MQTT.fx software and configure the MQTT Broker information.

www.SSTAutomation.com

30

(2) Click the Connect button to establish communication. Select the ‘Subscribe’ button, enter the published Topic name Topic0, and the data value of Tag3_R in KEPServerEX can be read. The example is shown below:

www.SSTAutomation.com

31

(3) Select the ‘Publish’ button, enter the subscribed Topic name Topic1, and according to the default data output format, the data value can be sent to Tag4_K in KEPServerEX. The example is shown below:

For the data format sent by the MQTT Broker, please refer to”3.3.1 MQTT Properties”.
3.6 How Do I… Import and Export Links Using a CSV File
OPGateway can import and export Links in CSV file format, which can quickly create/modify project files.
1. Inporting Links from a CSV File (1) Right-click on Group/Topic to open the context menu, and select [Import CSV…]

(2) A file open window will pop up. Select the CSV file and click ‘Open,’ and the Group/Topic

www.SSTAutomation.com

32

will automatically add the Link information from the CSV file.
2. Exporting Links to a CSV File (1) Right-click on Group/Topic to open the context menu, and select [Export CSV…] (2) A save window will pop up. Enter a file name and click ‘Save’ to save the Links in the Group/Topic to the CSV file.

www.SSTAutomation.com

33

3.7 Apply/Start/Stop/Restart Service
In the menu bar, under [Service], you can perform operations such as Apply, Start, Stop, and Restart the service. When changes are made to the project file, click “Apply” to make the changes take effect.
In the Task Manager under “Services”, you can view the current status of the service.

1. Apply Service
Click [Service -> Apply] in the menu bar to immediately apply the current configuration. If the configuration has not been saved, save the file first and then apply the configuration.

2. Start Service

www.SSTAutomation.com

34

When the OPGateway service is stopped, click [Service -> Start] in the menu bar to start the service.
3. Stop Service When the OPGateway service is running, click [Service -> Stop] in the menu bar to stop the service.
4. Restart Service When the OPGateway service is running, click [Service -> Restart] in the menu bar to restart the service. If the OPGateway service has been stopped, this will be a “Start Service” operation instead.

www.SSTAutomation.com

35

3.8 Check for updates
When the computer is connected to the network, click [Help -> Check for Updates] in the menu bar to check if the current software version is up to date. If it is not the latest version, in the “Software Update” window, you can click the “Install Update” button to update to the latest version. Alternatively, you can click “Skip this version” to skip the update or click “Remind me later” to update at a later time.

www.SSTAutomation.com

36

Appendix
KEPServerEX Software Project File Description
A brief explanation of creating a project file with KEPServerEX software used as an OPC Server. 1. Adding a Channel: (1) In the tree view, right-click on the Connectivity node and select New Channel (or choose
Edit | Connectivity | New Channel).
(2) Select type of channel to be created from the drop-down list of available drivers. Select Simulator driver.

(3) Click Next,enter the Channel name, all following settings are default until completed.

www.SSTAutomation.com

37

2. Adding a Device: (1) Right-click and select New Device or choose Edit | Connectivity | New Device.
(2) Enter the Device name, all following settings are default until completed.

3. Adding Tags: Set the Tag according to the example content below:

www.SSTAutomation.com

38

The project file for KEPServerEX software has been created.
4. View Data: Click the QC button on the toolbar to check the data transmission results.