  • Support for a high-security centralized access control system with separation of reading and control.
  • Supports Modbus and SOYAL communication protocols, suitable for various IoT integration applications.
  • Built-in input optocoupler protection function, effectively achieving electrical isolation, high voltage protection, lightning resistance, and avoiding noise interference.
  • Versatile application modes: standard I/O, multi-door interlock, people counting, crowd control, etc., easily meeting various application scenarios.
  • Compatible with Modular DIN Rail Mounting Base (AR-701B)

Specification

Interface Serial port RS485 X 1 port
Baud Rate 9600,19200 bps (N,8,1)
Input/Output 16 Digital Input / 8 Relay Output (Form C)
Protocol Modbus, Soyal protocol
LED Indicator Power,Tx/Rx, D.O./D.I
Watchdog function Yes
Operating Temperature -20℃ ~ +70℃
Fuses Power and RS485 Isolation protection
Noise Isolation Input optical isolation
Power Supply 9-24 VDC
Power Consumption <4W
 

Dimension(mm)

PCB:117(H)x148(W)x20(D)

Panel Mounting Base :117(H)x175(W)x30(D) Metal Box:180(H)x231(W)x62(D)

Weight(g) 100±10(PCB Only)

Installation(mm)

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-2

PIN Assignments

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-3

CN1

Function Pin Description
Main Power Supply (Single Power Supply Mode) (DC12V/1W) 1 V+
2 V-

CN2

Function Pin Description
External Port 1

(RS-485 input)

1 L1-(B-)
2 L1+(A+)

CN3~10

Function Pin Description
Relay output 1~8 1 N.O.
2 COM
3 N.C.
  • 701ClientSQL Graphic Animation I/O mapping starts from 00(Physical IO Address DI1 –>Symbol IO Nr.:00, Physical IO Address DI16 –>Symbol IO Nr.:15

CN11

Function Pin Description
DI input 1 DI.1
2 DI.2
3 DI.3
4 DI.4
5 COM

CN12

Function Pin Description
DI input 1 DI.5
2 DI.6
3 DI.7
4 DI.8
5 COM

CN13

Function Pin Description
DI input 1 DI.9
2 DI.10
3 DI.11
4 DI.12
5 COM

CN14

Function Pin Description
DI input 1 DI.13
2 DI.14
3 DI.15
4 DI.16
5 COM

Module I/O (16 Optical Isolation Input / 8 Relay Output)

DIP Switch Setting
Standard Firmware

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-4

Interlock Door Solution

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-5

Wiring Diagram

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-6

Wiring Method for High-Security Mode

Feature Introduction

  • The high-security mode architecture offers several advantages:
  • Power Failure Continuation: A backup mechanism for uninterrupted operation during power outages.
  • Centralized Control: Electric locks, open door buttons, and door position detection are all centralized in the equipment room, reducing the risk of I/O control leakage.
  • Advanced Anti-Tailgating: Support for interlock control of up to 8 doors to prevent unauthorized entry.

Wiring Diagram

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-7

 

Door Name

Channel 1 Channel 2 Common Contact
Lock Push Button Door Sensor Controller
Door A DO1 DI1 DI2 Node ID 009  

 

 

Fire Alarm

Door B DO2 DI3 DI4 Node ID 010
Door C DO3 DI5 DI6 Node ID 011
Door D DO4 DI7 DI8 Node ID 012
Door E DO5 DI9 DI10 Node ID 013
Door F DO6 DI11 DI12 Node ID 014
Door G DO7 DI13 DI14 Node ID 015
Door H DO8 DI15 DI16 Node ID 016

Software Setting

Setting Method

  • STEP 1: SelectSOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-8 in 701ServerSQL.
  • STEP 2: Click ” 721E16/Ev5 “
  • STEP 3: Check the required functions for RS-485 card readers with station numbers 09 to 16 on CH2.
  • When CH1 is connected to the I/O expansion board, it is necessary to deselect station numbers 01 to 08.

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-9

SOYAL-AR-401-IO-1608R-WEB-PLC-and-Expansion-I-O-Module-FIG-10 701ServerSQL Screen Names Function Description
1 Anitipa Anti-pass-back
2 Indoor Entry/Exit Reader
3 Egress Exit by Push Button
4 TimeAt Entry and Exit Access is recorded on the Duty Report
5 ForceA Enable force Open trigger alarm
6 Relok Activate close door automatically lock (Auto-Relock)
7 OpenZo Auto Open