Product

Features
- Support for a high-security centralized access control system with separation of reading and control.
- Supports Modbus and SOYAL communication protocols, suitable for various IoT integration applications.
- Built-in input optocoupler protection function, effectively achieving electrical isolation, high voltage protection, lightning resistance, and avoiding noise interference.
- Versatile application modes: standard I/O, multi-door interlock, people counting, crowd control, etc., easily meeting various application scenarios.
- Compatible with Modular DIN Rail Mounting Base (AR-701B)
Specification
| Interface | Serial port | RS485 X 1 port |
| Baud Rate | 9600,19200 bps (N,8,1) | |
| Input/Output | 16 Digital Input / 8 Relay Output (Form C) | |
| Protocol | Modbus, Soyal protocol | |
| LED Indicator | Power,Tx/Rx, D.O./D.I | |
| Watchdog function | Yes | |
| Operating Temperature | -20℃ ~ +70℃ | |
| Fuses | Power and RS485 Isolation protection | |
| Noise Isolation | Input optical isolation | |
| Power Supply | 9-24 VDC | |
| Power Consumption | <4W | |
|
Dimension(mm) |
PCB:117(H)x148(W)x20(D)
Panel Mounting Base :117(H)x175(W)x30(D) Metal Box:180(H)x231(W)x62(D) |
|
| Weight(g) | 100±10(PCB Only) | |
Installation(mm)

PIN Assignments

CN1
| Function | Pin | Description |
| Main Power Supply (Single Power Supply Mode) (DC12V/1W) | 1 | V+ |
| 2 | V- |
CN2
| Function | Pin | Description |
| External Port 1
(RS-485 input) |
1 | L1-(B-) |
| 2 | L1+(A+) |
CN3~10
| Function | Pin | Description |
| Relay output 1~8 | 1 | N.O. |
| 2 | COM | |
| 3 | N.C. |
- 701ClientSQL Graphic Animation I/O mapping starts from 00(Physical IO Address DI1 –>Symbol IO Nr.:00, Physical IO Address DI16 –>Symbol IO Nr.:15
CN11
| Function | Pin | Description |
| DI input | 1 | DI.1 |
| 2 | DI.2 | |
| 3 | DI.3 | |
| 4 | DI.4 | |
| 5 | COM |
CN12
| Function | Pin | Description |
| DI input | 1 | DI.5 |
| 2 | DI.6 | |
| 3 | DI.7 | |
| 4 | DI.8 | |
| 5 | COM |
CN13
| Function | Pin | Description |
| DI input | 1 | DI.9 |
| 2 | DI.10 | |
| 3 | DI.11 | |
| 4 | DI.12 | |
| 5 | COM |
CN14
| Function | Pin | Description |
| DI input | 1 | DI.13 |
| 2 | DI.14 | |
| 3 | DI.15 | |
| 4 | DI.16 | |
| 5 | COM |
Module I/O (16 Optical Isolation Input / 8 Relay Output)
DIP Switch Setting
Standard Firmware

Interlock Door Solution

Wiring Diagram

Wiring Method for High-Security Mode
Feature Introduction
- The high-security mode architecture offers several advantages:
- Power Failure Continuation: A backup mechanism for uninterrupted operation during power outages.
- Centralized Control: Electric locks, open door buttons, and door position detection are all centralized in the equipment room, reducing the risk of I/O control leakage.
- Advanced Anti-Tailgating: Support for interlock control of up to 8 doors to prevent unauthorized entry.
Wiring Diagram

|
Door Name |
Channel 1 | Channel 2 | Common Contact | ||
| Lock | Push Button | Door Sensor | Controller | ||
| Door A | DO1 | DI1 | DI2 | Node ID 009 |
Fire Alarm |
| Door B | DO2 | DI3 | DI4 | Node ID 010 | |
| Door C | DO3 | DI5 | DI6 | Node ID 011 | |
| Door D | DO4 | DI7 | DI8 | Node ID 012 | |
| Door E | DO5 | DI9 | DI10 | Node ID 013 | |
| Door F | DO6 | DI11 | DI12 | Node ID 014 | |
| Door G | DO7 | DI13 | DI14 | Node ID 015 | |
| Door H | DO8 | DI15 | DI16 | Node ID 016 | |
Software Setting
Setting Method
- STEP 1: Select
in 701ServerSQL. - STEP 2: Click ” 721E16/Ev5 “
- STEP 3: Check the required functions for RS-485 card readers with station numbers 09 to 16 on CH2.
- When CH1 is connected to the I/O expansion board, it is necessary to deselect station numbers 01 to 08.

| 701ServerSQL Screen Names | Function Description | |
| 1 | Anitipa | Anti-pass-back |
| 2 | Indoor | Entry/Exit Reader |
| 3 | Egress | Exit by Push Button |
| 4 | TimeAt | Entry and Exit Access is recorded on the Duty Report |
| 5 | ForceA | Enable force Open trigger alarm |
| 6 | Relok | Activate close door automatically lock (Auto-Relock) |
| 7 | OpenZo | Auto Open |