SELTRON-LOGO

SELTRON RCD20 Series Digital Room Unit for Heating Controller

SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-PRODUCT

Description

SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 2The battery is 100% full.
Battery charging required.
The battery is charging
The connection to the smart device is established.
The connection to the smart device is being established.
Wireless connection with the controller is established. The signal is excellent.
Wireless connection with the controller is established. The signal is good.
Wireless connection with the controller is established. The signal is weak.
The wireless connection to the controller is being established or cannot be established.
Locked keypad / access to the room unit is limited.
Room unit operation malfunction

ButtonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 3 to turn off the function and exit the settings.
ButtonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 to reduce the value and move back.
ButtonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 5 to enter and confirm the settings.
ButtonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 to increase value and move forward.
ButtonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 7 for user functions / smart device connection.
ConnectionSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 8 for charging the built-in battery is type USB-C. Only for wireless room unit.
SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 9Switching off the heating or cooling of the premises. Protection against freezing or overheating is active.

Room heating.
Room cooling.

SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 10Operation according to the required daily temperature.
Operation according to the required night temperature.

SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 11Measured room temperature.
Party function is activated.
The Eco function is activated.
The Holiday function is activated.
The Fireplace function is activated
D. h. w. according to the time program.
D. h. w. – permanent activation
Function for one-time d. h. w. heating is activated.

Charging the battery before use

(applies only to wireless models)
Room unit has a built-in rechargeable battery. We recommend that you fully charge the battery before you start using the room unit. For charging, you can use any household charger that has a USB-C connector. The battery charging port is located on the lower part of the room unit. Charging the battery can take up to 10 hours under normal conditions and needs to be charged once a year.

To charge the battery, the room unit does not need to be removed from its base.
The wireless room unit is delivered in battery saving mode. This state is signaled by the display »St.by«. When pressing any button on the room unit, the battery saving mode is cancelled for 1 hour. When the room unit is connected to the controller for the first time, the battery saving mode is permanently cancelled. If the room unit fails to connect to the controller within one hour, it will return to the battery saving mode.

Activation and deactivation of operation

With a 1 second press buttonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 3 we choose between the operating modes of the room unit. Depending on the controller model, we can choose between room heating, room heating & d.h.w. heating, d.h.w. heating and heating off.

Choosing the mode of operation: heating or cooling

By pressing the buttonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 3 for 10 seconds choose between heating or cooling operation mode. The operating mode can only be selected if the operation of the room unit is switched offSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 3

Setting the requested day and night temperature

The requested day and night temperature can be set when the operation is switched on. By pressing theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 andSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 button, we open the setting of the requested temperature (day or night), which is active at that moment. Set the requested temperature with theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 andSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 buttons. By pressingSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 button, we move to the next temperature setting. By pressing theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 5 button again, we leave the temperature setting.

User functions

By pressing buttonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 7, we select between user functions. Confirm the selected function with theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 5 button. Then select the requested function temperature with theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 andSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 button, and confirm it with theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 5 button. Lastly, with theSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 4 andSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 6 button, select the time or date of the function automatic expiration. By pressing the buttonSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 5, we leave the setting of the user function.
The following functions are available:

SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 12For operation at a comfortable temperature
For operation at the economy temperature
For operation with holiday temperature
For one-time activation of d.h.w. heating
For operation regardless of room temperature

Control of the room unit with a smart device

Download the Clausius BT app from the Google Play Store for Android devices or the Apple iStore for iOS devices. Open the app and click the iconSELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 13 to add a new device and follow the app’s instructions.SELTRON-RCD20-Series-Digital-Room-Unit-for-Heating-Controller-FIG 14

T: +386 (0)2 671 96 00
F: +386 (0)2 671 96 66
info@seltron.eu
www.seltron.eu

Documents / Resources

SELTRON RCD20 Series Digital Room Unit for Heating Controller [pdf] User Manual
RCD20 Series Digital Room Unit for Heating Controller, RCD20 Series, Digital Room Unit, RCD20 Series Digital Room Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *