Contents
hide
SALTO XS4 Access Control Reader
PARTS
Installation
- Gang electrical standard box
- Metal plate
- Fixing
- Included
- Metal plate
- Gang electrical standard box
- Fixing
Surface mounting installation with WRMBH1 base
- Fixing
- Metal plate
Surface mounting installation with WRMFHAV base
- Fixing
- Included
- Metal plate
Installation example
- Only conect to CU42xx
- Same pair
- 3M Scotchlok butt connector UY2. Crimp with cap side down.
Cable connection
installation example with RJ45
Minimum distance between readers 20in (50cm).
Electrical characteristics
Operation conditions
Min | Max Unit | |
Temperature | ‐35 | 66 ºC |
Humidity | 35 | 85 % |
RF characteristics
Min | Cen. | Max | Unit | |
RFID frequency | 13.56 | Mhz | ||
Bluetooth Smart frequency | 2.4 | 2.445 | 2.483 | Ghz |
Cable type and max. distances
Cable type Reader |
UTP Cat5e 2 pairs 100m
AWG24 |
UTP Cat5e 4 pairs 250m
AWG24 + SP224861/SP224895 |
Twisted pairs 400m
AWG18 Note 2 |
SIGNALLING
Signal | Light | Time (sec) | Buzzer | Time (sec) |
Card Rejection | Red | 1 | High pitched 50/50 | 1 |
Privacy or emergency status | Red 5x(50/50×3+off300) | 3 | High pitched 5x(50/50×3 + off 300) | 3 |
Standard opening | Green | 1 | Low pitched | 0,3 |
Standard locking | Red | 0,5 | Low pitched | 0,2 |
Open plus office | Green 400/200 | 2,4 | High pitched/Low pitched 400/200 | 2,4 |
CLR Button | Orange | Cont. | High pitched | Cont. |
Reset | Orange 50/100 | 450 msg | Low pitched 50/100 | 450 msg |
European view
All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials.
Documents / Resources
![]() |
SALTO XS4 Access Control Reader [pdf] Installation Guide XS4, Access Control Reader |