SALTO logo

SALTO WRDx0s4xK Series XS4 Reader

SALTO WRDx0s4xK Series XS4 Reader

WRDx0E4x
WRDx0S4x
WRDx0E4xK
WRDx0s4xK series

Tools Need

SALTO WRDx0s4xK Series XS4 Reader fig1

Dimension

SALTO WRDx0s4xK Series XS4 Reader fig2

Installation

SALTO WRDx0s4xK Series XS4 Reader fig4

Gang electrical standard box

SALTO WRDx0s4xK Series XS4 Reader fig5

UL Statements

Tested by UL with Mifare (DESFIRE, ULTRALIGHT C) and HID iCLASS RFID communication, and with Mobile APP (JustIN Movile version 2.x) through Bluetooth version 4.2. Minimum Operating System version for Android: 4.3 or later and for iOS: 10.0 or later. A means of verification shall be employed by the user to enable access to the wireless electronic device such as a PIN or biometric feature. The wireless electronic device is not capable of command, control, programming, or any other system manipulation and it is only to be used in the same manner as a physical credential. Wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70 or CSA C22.1-02 – Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations

UL294 performance level:

SALTO WRDx0s4xK Series XS4 Reader fig8

– Comply with ULC-S319 Class I
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to ICES-003. European view

Electrical characteristics

Operation conditions

Min. Max. Unit
TemperatureWRD0B – WRD0BK-35

-31

+66        °C

+150       °F

TemperatureWRD0J – WRD0GK – WRD0JK-25

-13

+66        °C

+150       °F

Humidity 3585          %

RF characteristics

MinCen.MaxUnit
RFID frequency 13.56 Mhz
Bluetooth Smart frequency2.42.4452.483Ghz

Power Consumption Note 1

MinMaxUnit
Reader150mA
Reader+Keyboard250mA

Note 1: Installer must take this data into
account to dimension the CU42xx power supply. Readers only for use with the SALTO Control Units.
Note 2: Not use with Scotchlok butt connector UY2 SALTO recommends to use one cable per wall reader.

Cable type and max. distances

Cable type      Reader     Reader

+keypad

UTP Cat5e 2 pairs 328ft     196ft AWG24                 100m 60m
UTP Cat5e 4 pairs 820ft 492ft AWG24 +              250m 150m

SP224861/SP224895

Twisted pairs        1312ft 918m AWG18 Note 2                400m 280m
Installation example:

SALTO WRDx0s4xK Series XS4 Reader fig6

  • Same pair
  • Only conect to CU42xx

Cable connectionSALTO WRDx0s4xK Series XS4 Reader fig9

Installation example with RJ45

SALTO WRDx0s4xK Series XS4 Reader fig7

Minimum distance between readers 20in (50cm).

SIGNALLING

SignalLightTime (sec)BuzzerTime (sec)
Card RejectionRed1High pitched 50/501
Privacy or emergency statusRed 5x(50/50×3+off300)3High pitched 5x(50/50×3 + off 300)3
Standard openingGreen1Low pitched0,3
Standard lockingRed0,5Low pitched0,2
Open plus officeGreen 400/2002,4High pitched/Low pitched 400/2002,4
CLR ButtonOrangeCont.High pitchedCont.
ResetOrange 50/100450 msgLow pitched 50/100450 msg

Documents / Resources

SALTO WRDx0s4xK Series XS4 Reader [pdf] Installation Guide
WRDx0E4x, WRDx0S4x, WRDx0E4xK, WRDx0s4xK series, WRDx0s4xK Series XS4 Reader, XS4 Reader