RICE LAKE LogoSCT-1SX-Ethernet/IP
Quick Start Guide
RICE LAKE SCT-1SX-Ethernet Indicators and Controller

Electrical Schematic

Warning icon Load cells excitation: 5 V.
Load cells output: 6 mV/V max.
Warning icon INPUT: 12 to 48 Vdc
OUTPUT: 48Vac or 60Vdc, 0.5 A max
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 1 For UL approved models: equipment to be powered by 12 to 24 Vdc LPS or Class 2 power source.
Warning icon CONSUMPTION: 4 W max. (without load cells).RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Electrical SchematicRICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 2 Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals
Warranty information is available at www.ricelake.com/warranties

Key Functions

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Key Functions

Configuration menu
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 3 Decreases digit / Scrolls down.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 4 Increases digit / Scrolls up.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 5 Enters the setup. Selects digit to modify.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 6 Enters a step / Confirms.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 7 Clears / Exits a step (no save).
Weighing mode
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 3 Clears the displayed gross weight.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 4 Short press: executes semiautomatic tare. Long press: allows to enter known tare.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 5 Activates / deactivates the function.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 6 Short press executes data transmission on the printer serial port.
Long press: Setpoint configuration.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 7 ON/Standby of the instrument.

Indicator Light Descriptions

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Indicator Light Descriptions

1 Weight on zero.
2 Unstable weight.
3 A tare is active.
4 A function is active.
5 Digital output 1 is active.
6 Digital output 2 is active.

Configuration Menu

  1. Reboot the weight transmitter
  2. Press the RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 5 key when display shows the RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 8 message:RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 1

HOW TO EXIT THE MENU AND SAVE YOUR CONFIGURATION

  1. Press RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 7 key repeatedly until RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 12 appears; press RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 6 to save or press RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 7 to exit without saving.

Maximum Scale Capacity, Increment and Decimal Point Settings

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 2 Set the decimal point position and the minimum scale increment*1
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 3
Set the maximum scale capacity*2 (max RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 13 ).

Examples:

For a 60000 lb scale, with 2 lb increment:RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 4 For a 10000 g scale, with 0.1 g increment:RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 5 For a 3000 lb scale, with 0.05 lb increment:RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 6

*1 Increment = the amount that the scale will increment by as weight is added or removed.
*2 Maximum capacity = the maximum weight that can be measured using the scale you are creating.

Theoretical Calibration

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 7 Set the total load cells capacity (up to RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 13).
Set the load cells sensitivity (up to RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 13). RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 9
Dead load weight (from -9999.9 to RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 13.RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 13).

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Theoretical Calibration

Zero Mechanical Tare (pre-tare zeroing)

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 8 Zeroing of the pre-tare (or mechanical tare).

This functionality allows to zero the weigh of the scale structure (e.g. empty silo, conveyor, etc.) without changing the calibration in memory.

Calibration with Sample Weight

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 9 Zero point acquisition.
Sample weight acquisition.

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 10

Load Cells Diagnostics (µV/V)

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 11It allows to verify signal of each channel. It must be included into the range 0 to 3 mV/V.
Signal have to be stable and it have to increase by increasing the weight on the scale.

Input Settings

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 12

Output Settings

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 13

11.1 HOW TO PROGRAM SETPOINTSRICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 14

Fieldbus Settings

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 15

Weight Filter

RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Fig 16The active weight filter is displayed, alternating with the weight value.
Press RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 4 and RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Icon 3 keys to scroll through the available filters (from slowest to fastest, F1 to F11).

Programming Errors

MESSAGE DESCRIPTION SOLUTION
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 1 Calibration error First calibrate the zero point (zero), then proceed with sample weight acquisition (sp n) (section 9).
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 2 Calibration error Check the connection of the load cell. Verify the load cell signal is stable, valid and greater than the previously acquired point.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 3 Calibration error Increase the calibration weight.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 4 Calibration error Check the signal from the load cell increases when weight is incremented on the scale.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 5 Calibration error Repeat calibration and verify capacity and division have been correctly set.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 6 Instrument not configured Transmitter needs to be configurated.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 7 Calibration error Verify the signal from the load cell is not negative.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 8 Calibration error Verify the signal from the load cell is not negative.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 9 Weight unstable Check in RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 14 parameter that the signal is stable.
If the connection of the cells is with 4 wires, check that the sense jumpers are inserted.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 10 A/D converter error Converter failure. Reboot the instrument.
RICE LAKE SCT-1SX-Ethernet Indicators and Controller - MESSAGE 11 Global load cell error Signal anomaly: check the load cells connection.

Ethernet/IP

15.1 ETHERNET/IP REGISTERS

Data Byte DESCRIPTION
Goss weight 0 (MSB) Bytes 1, 2, 3 and 4 contain the Gross Weight value.
1
2
3 (LSB)
Net weight 4 (MSB) Bytes 5, 6, 7 and 8 contain the Net Weight value.
5
6
7 (LSB)
Input status register 8 (MSB) Bit 15(msb)
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8 (lsb)
Active channel.
Active channel.
No function.
No function.
No function.
No function.
Status of input n. 2.
Status of input n. 1.RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Active Channel
9 (LSB) Bit 7(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 (lsb)
1 = Scale unloaded (gross weight = 0). Tare PT (1 = PT tare is active).

Tare (1 = Tare is active).

Overload condition (0 = No; 1 = Overload). Underload condition (0 = No; 1 = Underload). Weight Stability (0 = Unstable; 1 = Stable).

Gross Weight Polarity (0 = “+”; 1 = “-”). Net Weight Polarity (0 = “+”; 1 = “-”).

Command status register 10 (MSB) Last received command.
11 (LSB) Bit 7(msb)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 (lsb)
Last command result. Last command result. Last command result. Last command result.
Counting of processed commands. Counting of processed commands.
Counting of processed commands. Counting of processed commands.
Output status register 12 (MSB) No Function.
13 (LSB) Bit 7(msb)

Bit 2
Bit 1
Bit 0(lsb)
No function.

No function.
Digital output 2 status (0 = OFF; 1 = ON). Digital output 1 status (0 = OFF; 1 = ON).
Selected page 14 (MSB) Shows the value of the selected page (3001).
15 (LSB)
µV 16 (MSB) µV value.
17 (LSB)

15.2 ETHERNET/IP REGISTERS FOR COMMAND SENDING

Data Byte DESCRIPTION
Not used 0 Always 0.
Command 1 Main available commands:RICE LAKE SCT-1SX-Ethernet Indicators and Controller - Active Channel 2
Parameter 1 2 (MSB) First parameter of the command.
Parameter is always expressed in absolute mode (no decimals, no sign).
3
4
5 (LSB)
Parameter 2 6 (MSB) Second parameter of the command.
Parameter is always expressed in absolute mode (no decimals, no sign).
7
8
9 (LSB)
10(MSB) Used in advanced configuration, refer to the complete Fieldbus manual for further information.
31 (LSB)

EXAMPLE 1
For zeroing the weight on the scale:
2. Set the command in byte 2

Byte Value
1 00 Hex
2 01 Hex

EXAMPLE 2
For setting a preset tare of 1000 lb:

  1. Set the tare value in parameter 1 (byte 3, 4, 5, 6)
  2. Set the command in byte 2
Byte Value
1 00 Hex
2 03 Hex
3(MSB) 00 Hex
4 00 Hex
5 03 Hex
6(LSB) E8 Hex

No

RICE LAKE LogoVisit our website www.RiceLake.com
230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171
© Rice Lake Weighing Systems Content subject to change without notice.
www.ricelake.com
PN 219716 Rev A
September 29, 2023