Specifications:
- Proximity switch for activation and access control
- Hard coated, scratch resistant, anti-reflective, anti-microbial
Steritouch acrylic label - Entire label is sensitive
- Power Supply: 12-28Vdc
- Batteries: 4 x AA (Square), 4 x AAA (Single Gang)
- Radio Frequency: 868MHz
- Dimensions: 65 x 50 x 30 mm
- Sounder & green LED on activation
- Battery saving design, unit will only activate once if hand
left on
Installation:
1. Wiring diagrams:
- Hardwired sensor wiring.
- Alter LED color configuration as required.
- Connect according to normally open contacts and voltage
returns.
2. Latch Jumper:
- Select between Momentary or Latching mode.
3. Remote Switch:
- Optional N.O. connection available.
4. Sensitivity Dip-Switches:
- Adjust sensitivity from Low to High.
- Power off, alter range, then re-power for changes to take
effect.
5. Sounder & Timer:
- Adjust timer from 1-27 seconds by turning anti-clockwise.
6. Radio Programming (RX-2 Receiver):
- Supply power and wire relay outputs correctly.
- Press and release the learn button to program touch
sensors. - Reset receiver by holding the learn button for 10 seconds.
FAQ:
Q: How do I reset the receiver?
A: To reset the receiver, press and hold the learn button for 10
seconds until the learn LED starts flashing. After this, the memory
will be deleted.
Q: What are the battery requirements for the product?
A: The Square unit requires 4 x AA batteries, while the Single
Gang unit requires 4 x AAA batteries.
“`
SQUARE & SINGLE GANG Manual
Proximity switch for activation and access control
Hard coated, scratch resistant, anti-reflective, anti-microbial Steritouch acrylic label Entire label is sensitive www.quantek.co.uk 01246 417113
Installation:
Ascertain fixing height. Use the box to mark the four fixing points. Use knockout and place cable through if hardwiring. Fit seal to back of box if being used externally (Square only), and secure box to the wall with 4 x No8 (4mm) screws. Make connections (see below, do not leave excessive cable in the back box), or connect battery clip and place battery holder in the marked compartment, then program into the receiver (see next page) Place signage plate back into the box and insert the two screws. Do not over tighten screws!
Hardwired specification: 12 28Vdc 8mA (standby) / 35mA (max) +18mA LEDs Sensitivity Touch – up to 70mm Selectable red, green, blue LEDs Sounder on activation Timer 1 – 27 seconds Latching function
Wiring diagrams
Hardwired sensor wiring. Alter LED colour configuration as required.
Normally open contacts. 0v return
Normally open contacts. +v return
12-28Vdc NO activate
0V return 0V
12-28Vdc NO activate
+V return 0V
Latch jumper Momentary Latching
Remote switch
N.O. (Optional)
Sensitivity dip-switches
1 – Low 4 – High Remove power alter range re power
Sounder
Timer
1-27 seconds Anti-clockwise to increase time
Note: Never connect anything to RD terminal If using a square illuminated unit, connect the LED wires to the terminals marked on the large outer LED panel PCB, instead of the touch sensor PCB
Radio programming (RX-2 receiver)
Supply receiver with 12/24Vdc power. +V to 12/24V terminal, -V to GND terminal. LED will light if powered correctly
Wire relay outputs to activate terminals on the system (clean, normally open contacts)
Press and release the learn button, the learn LED will light up for 10 seconds
Within the 10 seconds operate the touch sensor
The learn LED will flash to confirm it has programmed Note: Touch sensors program to channel 1. The RX-T receiver will be required if you need to program them to different channels. It is also possible to program our handheld and desk mount transmitters (CFOB, FOB1-M, FOB2-M, FOB2-MS, FOB4- M, FOB4-MS, DDA1, DDA2) into this receiver using the same method. See transmitter box for more details.
Reset: To reset the receiver, press and hold the learn button for 10 seconds until the learn LED starts flashing. After this the memory will be deleted
Radio specification
868MHz 4 x AA batteries (Square) 4 x AAA batteries (SG) Approximately 100,000 operations Sounder & green LED on activation Battery saving design, unit will only activate once if hand left on
Receiver specification
12/24Vdc supply 868MHz 2 channels 1A 24Vdc normally open contacts Momentary/bi-stable selectable relays 200 code memory Dimensions: 65 x 50 x 30 mm
Dipswitch settings
ON
OFF
1
CH1 – Bi-Stable
CH1 – Momentary
2
CH2 – Bi-Stable
CH2 – Momentary
Programming video
Note: Matching screw cover stickers are supplied as an optional feature for aesthetic purposes. If required, they should be affixed after the unit has been installed. To affix them, simply peel off the yellow adhesive backing and stick them over the two screws. They can be easily removed with a knife for battery changes. Spares are may also be supplied, these should be left inside the unit.