PANDUIT CJ588-Y Mini Com Jack Modules
Specifications
- Part Numbers: CJ588**Y
- Termination: PN45H
- Can terminate PVC or Plenum rated 22-24 AWG solid or stranded
IWC cable with insulated conductor outside diameter ranging between 0.035 inch (0.88mm) and 0.048 inch (1.2mm) - Jack Modules may be re-terminated a minimum of 10 times
Product Usage Instructions
- Remove all but one twist per pair, smooth conductors, and arrange in proper color sequence.
- Follow TIA/EIA 568-B installation guidelines for specified performance.
Refer to the wiring diagram for Part Number CJ588 for modular plug contacts and insulation displacement contacts.
Safety Precautions
- Never install communications wiring during a lightning storm.
- Avoid installing communications wiring in wet locations unless the jack is specifically designed for such use.
- Avoid touching uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
- Exercise caution when installing or modifying communication wiring.
FAQ
- Q: Can the Jack Modules terminate both solid and stranded cables?
- A: Yes, the Jack Modules can terminate PVC or Plenum-rated 22-24 AWG solid or stranded IWC cable.
- Q: How many times can the Jack Modules be re-terminated?
- A: The Jack Modules may be re-terminated a minimum of 10 times.
INSTALLATION INSTRUCTIONS
TERMINATION
- Remove all but one twist per pair, smooth conductors and arrange in proper color sequence.
- Mini-Com Mini-Jack Color-Coded Wire Positions
Part Numbers – CJ588**Y, CJ5E88**Y, CJD588**Y | |||||
T568A | T568B | ||||
2 | GREEN | R3 | 2 | ORANGE | R2 |
1 | WHITE/GREEN | T3 | 1 | WHITE/ORANGE | T2 |
3 | WHITE/ORANGE | T2 | 3 | WHITE/GREEN | T3 |
5 | WHITE/BLUE | T1 | 5 | WHITE/BLUE | T1 |
4 | BLUE | R1 | 4 | BLUE | R1 |
6 | ORANGE | R2 | 6 | GREEN | R3 |
8 | BROWN | R4 | 8 | BROWN | R4 |
7 | WHITE/BROWN | T4 | 7 | WHITE/BROWN | T4 |
TERMINATION CAP REMOVAL
WIRING DIAGRAMS
WIRING DIAGRAMS FOR CJ588
Notes
- For specified performance, follow TIA/EIA 568-B installation guidelines.
- Jack Modules can terminate PVC or Plenum-rated 22-24 AWG solid or stranded IWC cable with insulated conductor outside diameter ranging between 0.035 inch (0.88mm) and 0.048 inch (1.2mm).
- Jack Modules may be re-terminated a minimum of 10 times.
- For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply
- Never install communications wiring during a lightning storm.
- Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
- Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
- Use caution when installing or modifying communication wiring.
For Instructions in Local Languages and Technical Support: www.panduit.com.