Installation Guide for PANDUIT models including: CJ588-Y, CJ588-Y Mini Com Jack Modules, Mini Com Jack Modules, Com Jack Modules, Jack Modules, Modules
Panduit CJ588IWY 8-Position 8-Wire White Category 5E Unshielded Twisted Pair Jack Module | Crawford Electric Supply
Mini-Com UTP RJ45 Cat 5e Leadframe Jack Module, Arctic White | Crescent Electric Supply Company
CJ588VLY PAN MODULE CAT5E UTP 8P8E | Kendall Electric Inc
File Info : application/pdf, 2 Pages, 252.33KB
DocumentDocumentMini-Com Mini-Jack Jack Modules Part Numbers: CJ588**Y © Panduit Corp. 2024 INSTALLATION INSTRUCTIONS TERMINATION PN45H 1 Remove all but one twist per pair, smooth conductors and arrange in proper color sequence. 78 6 4 5 3 12 Mini-Com Mini-Jack Color-Coded Wire Positions Part Numbers - CJ588**Y, CJ5E88**Y, CJD588**Y T568A T568B 2 GREEN R3 2 ORANGE R2 1 WHITE/GREEN T3 1 WHITE/ORANGE T2 3 WHITE/ORANGE T2 3 WHITE/GREEN T3 5 WHITE/BLUE T1 5 WHITE/BLUE T1 4 BLUE R1 4 BLUE R1 6 ORANGE R2 6 GREEN R3 8 BROWN R4 8 BROWN R4 7 WHITE/BROWN T4 7 WHITE/BROWN T4 2 3 CWST Snipping Tool 4 5 CWST 6 ** Denotes color. 7 CJT SNAP TOOL (OR) For Technical Support: www.panduit.com Page 1 of 2 © Panduit Corp. 2024 1 INSTALLATION INSTRUCTIONS TERMINATION CAP REMOVAL 2 PN45H WIRING DIAGRAMS FOR CJ588 WIRING DIAGRAM Part Numbers CJ588 Modular Plug Contacts Insulation Displacement Contacts 1 2 2 1 3 3 4 5 5 4 6 6 7 8 8 7 Pin #'s 18 Notes: 1. For specified performance, follow TIA/EIA 568-B installation guidelines. 2. Jack Modules can terminate PVC or Plenum rated 22-24 AWG solid or stranded IWC cable with insulated conductor outside diameter ranging between 0.035 inch (0.88mm) and 0.048 inch (1.2mm). 3. Jack Modules may be re-terminated a minimum of 10 times. 4. For technical and performance information, consult Panduit Technical Support. As with all Wiring Accessories, the following statements apply: 1. Never install communications wiring during a lightning storm. 2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations. 3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface. 4. Use caution when installing or modifying communication wiring. For Instructions in Local Languages and Technical Support: www.panduit.com www.panduit.com Page 2 of 2 E-mail: techsupport@panduit.com Fax: (866) 405-6654 REV .06