Installation Instructions

Mini-Com UTP RJ45 Cat 5e Leadframe Jack Module, Arctic White | Crescent Electric Supply Company

CJ588VLY PAN MODULE CAT5E UTP 8P8E | Kendall Electric Inc


File Info : application/pdf, 2 Pages, 252.33KB

PDF preview unavailable. Download the PDF instead.

10965 NB0QD87J3W2ORKMA
Mini-Com Mini-Jack Jack Modules
Part Numbers: CJ588**Y

© Panduit Corp. 2024

INSTALLATION INSTRUCTIONS
TERMINATION

PN45H

1 Remove all but one twist per pair, smooth conductors and arrange in proper color sequence. 78 6 4 5 3 12

Mini-Com Mini-Jack Color-Coded Wire Positions

Part Numbers - CJ588**Y, CJ5E88**Y, CJD588**Y

T568A

T568B

2 GREEN

R3 2 ORANGE

R2

1 WHITE/GREEN T3 1 WHITE/ORANGE T2

3 WHITE/ORANGE T2 3 WHITE/GREEN T3

5 WHITE/BLUE

T1 5 WHITE/BLUE

T1

4 BLUE

R1 4 BLUE

R1

6 ORANGE

R2 6 GREEN

R3

8 BROWN

R4 8 BROWN

R4

7 WHITE/BROWN T4 7 WHITE/BROWN T4

2

3

CWST
Snipping Tool

4

5

CWST

6
** Denotes color.

7
CJT SNAP TOOL
(OR)
For Technical Support: www.panduit.com
Page 1 of 2

© Panduit Corp. 2024
1

INSTALLATION INSTRUCTIONS
TERMINATION CAP REMOVAL
2

PN45H

WIRING DIAGRAMS FOR CJ588

WIRING DIAGRAM

Part Numbers CJ588

Modular Plug Contacts

Insulation Displacement
Contacts

1

2

2

1

3

3

4

5

5

4

6

6

7

8

8

7

Pin #'s 18

Notes: 1. For specified performance, follow TIA/EIA 568-B installation guidelines. 2. Jack Modules can terminate PVC or Plenum rated 22-24 AWG solid or stranded IWC cable with insulated conductor
outside diameter ranging between 0.035 inch (0.88mm) and 0.048 inch (1.2mm). 3. Jack Modules may be re-terminated a minimum of 10 times. 4. For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply: 1. Never install communications wiring during a lightning storm. 2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations. 3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected
at the network interface. 4. Use caution when installing or modifying communication wiring.

For Instructions in Local Languages and Technical Support:
www.panduit.com

www.panduit.com Page 2 of 2

E-mail: techsupport@panduit.com
Fax: (866) 405-6654

REV .06

