MOXA-Logo

MOXA AIG-302 Series Advanced IIoT Gateway

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Product

Product Information

Specifications

  • Model: AIG-302 Series
  • Version: 1.0, April 2024
  • Manufacturer: Moxa Inc.
  • Package Contents: Check with your sales representative

Product Usage Instructions

  • Panel Views
    The AIG-302 Series has different panel layouts based on the model. Refer to the user manual for detailed panel views.
  • LED Indicators
    LED indicators provide information on power status, system operation, cellular signal strength, WLAN signal strength, and Ethernet link status.
  • Mounting Instructions
    DIN-rail Mounting
    1. Pull down the bottom slider of the DIN-rail bracket.
    2. Insert the top of the DIN rail into the slot below the upper hook.
    3. Latch the unit firmly onto the DIN rail and push the slider back into place.
  • Wall Mounting (optional)
    1. Fasten the wall-mounting brackets on the left panel of the device using four screws.
    2. Mount the device on a wall or in a cabinet using another four screws.
      IMPORTANT: Follow the specified screw dimensions for wall mounting to ensure proper installation.
  • Wiring Requirements
    Ensure proper wiring practices by separating signal or communication wiring from power wiring to avoid interference. Route wires with different signal characteristics separately.
  • Grounding Requirements
    Connect the grounding connector on the top panel to a grounded metal surface to limit noise effects due to electromagnetic interference (EMI).

Frequently Asked Questions (FAQ)

  • Q: Is the console cable included in the package?
    A: No, the console cable is not included. It needs to be purchased separately. Contact your sales representative if any items are missing or damaged.
  • Q: How do I check the Ethernet link status?
    A: The LED indicator on LAN1/LAN2 provides information on the Ethernet link status. Green indicates a 1000 Mbps link, yellow indicates a 100 Mbps link, and off indicates no connection or a 10 Mbps link.

Package Checklist

Before installing the device, verify that the package contains the following items:

  • AIG-302 Series advanced IIoT gateway
  • Power jack
  • DIN-rail mounting kit
  • Quick installation guide (printed)
  • Warranty card

IMPORTANT!
The console cable is not included in the package; you need to purchase it separately. Notify your sales representative if any of the above items are missing or damaged.

Panel Views

The following figures show the panel layouts of the AIG-302 Series:

AIG-302-T-AZU-LX

Top Panel

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (1)

Front Panel 

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (2)

Bottom Panel 

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (3)

AIG-302 US, EU, and AP Models

Top Panel

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (4)

Front Panel 

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (5)

Bottom Panel View 

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (6)

LED Indicators

LED Name Status Function
PWR1/PWR2 Green Power is on
Off No power is supplied
SIM Green SIM2 in use
Yellow SIM1 in use
USR Green/Yellow Green: System is operating normally Yellow: System is initializing and running the initial boot-up process
L1/L2/L3 Yellow Cellular signal strength
L1+L2+L3: Strong L2+L3: Normal

L3:Weak

W1/W2/W3 Yellow WLAN signal strength
W1+W2+W3: Strong W2+W3: Normal W3: Weak
LAN1/LAN2 (RJ45

connector)

Green Steady on 1000 Mbps Ethernet link
Blinking Data is being transmitted
Yellow Steady on 100 Mbps Ethernet link
Blinking Data is being transmitted
Off No Ethernet connection or 10 Mbps Ethernet link

Mounting Instructions

DIN-rail Mounting
The aluminum DIN-rail attachment plate is already attached to the product’s casing. To mount the device onto a DIN rail, make sure that the stiff metal spring is facing upwards and follow these steps.

  1. Pull down the bottom slider of the DIN-rail bracket located at the back of the unit
  2. Insert the top of the DIN rail into the slot just below the upper hook of the DIN rail bracket.
  3. Latch the unit firmly onto the DIN rail as shown in the illustrations below.
  4. Push the slider back into place.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (7) MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (8)

Wall Mounting (optional)
The device can be mounted onto a wall using a wall-mounting kit. The optional wall-mounting kit should be purchased separately.

Follow these steps to mount the device onto a wall:

Step 1
Use four screws to fasten the wall-mounting brackets on the left panel of the device.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (9)

Step 2
Use another four screws to mount the device onto a wall or in a cabinet.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (10)

IMPORTANT!
The diameter of the screw heads should be greater than 7 mm and less than 14 mm; the diameter of the shafts should be less than 3 mm. The length of the screws should be greater than 6 mm.

NOTE

  • Test the screw head and shank size by inserting the screws into one of the keyhole-shaped apertures of the wall-mounting plates before attaching the plate to the wall.
  • Do not drive the screws in all the way—leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.

Wiring Requirements

  • Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
  • You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
  • Keep input wiring and output wiring separate.
  • When necessary, it is strongly advised that you label wiring to all devices in the system.

NOTE
Do not run signal or communication wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.

Grounding Requirements

There is a grounding connector located on the top panel of the device. Connect it to an appropriate grounded metal surface. Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI).

Connecting the Power Supply
Connect the power jack (in the package) to the DC terminal block (located on the top panel), and then connect the power adapter. It takes about 3 minutes for the system to boot up. Once the system is ready, the Power LED will light up. Both models support dual power inputs for redundancy.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (11)

ATTENTION 

WIRING CAUTION 

  • Use wires with 12 to 26 AWG wire sizes to connect to V+, V-, and GND.
  • The wire size of the power input and the earthing conductor should be the same.
  • Remove 8 to 9 mm of the DC wires’ protective cover and use a torque of 4.5lb-in/0.51Nm to connect the wire.
  • The max. wire temperature should not exceed 100°C.
  • The terminal blocks do not accommodate more than one conductor wire per clamping point.

WARNING 

  • This product is intended to be supplied by a UL-listed power adapter or DC power source whose output meets SELV/LPS. The power source must be rated 12 to 48 VDC, minimum 1 A, and minimum TMA = 85°C.
  • The power adapter should be connected to a socket outlet with an earthing connection.

If you need further information or assistance, contact a Moxa representative.

Wiring the I/Os 

  • There are four digital inputs and four digital outputs on the top panel. Refer to the figure on the left for detailed pin definitions.
  • Use wires with 16 to 28 AWG wire sizes to connect to DI, DO, and GND.
  • The exposed conductor wire length should be 7-8 mm and the max. wire temperature should not exceed 100°C. The terminal blocks do not accommodate more than one conductor wire per clamping point.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (12)

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (13)

Communication Connections

Connecting to the Network
The two 10/100/1000 Mbps Ethernet ports (LAN 1 and LAN 2) use RJ45 connectors.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (14)

Pin

10/100 Mbps

1000 Mbps

1 Tx+ TRD(0)+
2 Tx- TRD(0)-
3 Rx+ TRD(1)+
4 TRD(2)+
5 TRD(2)-
6 Rx- TRD(1)-
7 TRD(3)+
8 TRD(3)-

Connecting to Serial Ports
The two serial ports (P1 and P2) use the DB9 interface. Each port can be configured by software for RS-232, RS-422, or RS-485. The pin assignments for the ports are shown in the following table:

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (15)

Pin

RS-232 RS-422

RS-485 2w

1 TxD-(A)
2 RxD TxD+(B)
3 TxD RxD+(B) Data+(B)
4 DTR RxD-(A) Data-(A)
5 GND GND GND
6 DSR
7 RTS
8 CTS

Inserting the microSD Card

  • The device comes with a microSD slot for storage expansion. The microSD slot is located at the lower part of the front panel. To install the card, remove the screw and the protection cover to access the slot and insert the microSD card into the slot.
  • You will hear a click when the card is in place. To remove the card, push the card in before releasing it.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (16)

Connecting to the Console Port
The console port is an RS-232 port located on the top panel and can be connected to a 4-pin pin header cable. You can use this port for debugging.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (17)

Pin Signal
1 TxD
2 RxD
3 NC
4 GND

Connecting a USB Device
The device comes with a USB port located on the lower part of the front panel, allowing users to connect to a device with a USB interface. The USB port uses a type-A connector.

Connecting a CAN Device
A CAN port with a DB9 interface is located on the bottom panel. Refer to the figure below for detailed pin definitions.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (18)

Pin Definition
1
2 CAN_L
3 CAN_GND
4
5 (CAN_SHLD)
6 (GND)
7 CAN_H
8
9 (CAN_V+)

Inserting a SIM Card
The device comes with two SIM card slots to install up to two SIM cards for cellular communication.

Step 1
Remove the screw on the SIM card holder cover located on the bottom panel of the device.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (19)

Step 2
Insert the SIM card into the socket. Make sure you insert it in the right direction. To remove the SIM card, press the SIM card in to release it and then pull out the SIM card.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (20)

Connecting the Antennas

  • There are two cellular antenna connectors (C1 and C2) on the front panel of the device. In addition, a GPS connector is provided for the GPS module. All three are SMA-type connectors. Connect the antennas to these connectors as indicated.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (21)
  • The device also comes with two Wi-Fi antenna connectors (W1 and W2) on the top panel of the device. Connect the antennas on the connectors as shown below. Both W1 and W2 connectors are of RP-SMA type.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (22)

Installing the Wi-Fi Module

The Wi-Fi module is not included in the package, you need to purchase it separately. The Wi-Fi module package includes the following items.

Follow these steps to install the Wi-Fi module for the AIG-302 Series.

  1. Remove the side cover of the AIG-302 to expose the Wi-Fi module socket. The Wi-Fi socket is located beside the cellular module socket.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (23)
  2. Remove the two silver screws on the socket.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (24)
  3. Install the Wi-Fi module in the socket and fasten two black screws on the module. Also, fasten the two bronze screws on the board.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (25)
  4. Remove the plastic protection covers on the antenna connectors.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (26)
  5. Connect the antenna cables to the Wi-Fi connectors.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (27)
  6. Install the heat sink pad on the module and then fasten two silver screws.MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (28)
  7. Replace the side cover.

NOTE
The optional Wi-Fi wireless module is not included in the product package and must be purchased separately.

Connecting the Device to a PC
You can use a PC to access the web console of the AIG-302 Series via LAN 2 at https://192.168.4.100:8443.

  • Default Username: admin
  • Password: admin@123

NOTE
For security reasons, the console port is disabled by default. You can enable it via the web console.

Troubleshooting

  • Reboot
    To reboot the device, press the Function (FN) button for 1 second.
  • Reset to Default
    Press and hold the Function (FN) button between 7 to 9 seconds to reset the device to the factory default settings. When the reset button is held down, the USR LED will blink once every second and become steady after 7 to 9 seconds. Release the button within this period to load the factory default settings.
  • Real-time Clock
    The real-time clock is powered by a lithium battery. We strongly recommend that you do not replace the lithium battery without the help of a Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team.

ATTENTION
There is a risk of explosion if the battery is replaced with an incorrect type of battery.

Product Specifications

Input Current 1 A @ 12 VDC
Input Voltage 12 to 48 VDC
Power Consumption 12 W
Operating Temperature •       -40 to 70°C (-40 to 158°F) (AIG-302-T-US- AZU-LX, AIG-302-T-EU-AZU-LX, AIG-302- T-AP-AZU-LX)

•       -40 to 85°C (-40 to 185°F) (AIG-302-T- AZU-LX)

Storage Temperature (package included) -40 to 85°C (-40 to 185°F)

The latest specifications for Moxa’s products can be found at https://www.moxa.com.

Hazardous Locations Specifications

Models AIG-302-T-AZU-LX, AIG-302-T-AP-AZU-LX, AIG-302-T-EU-AZU-LX, AIG-302-T-US-AZU-LX
Rating 12 to 48 VDC, 1.0 to 0.25 A
ATEX information MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (29)

UL 24 ATEX 3193X

Ex ec IIC T4 Gc Ambient Range :

-40°C ≦ Tamb ≦ 85°C (for model AIG-302-T-AZU-LX)

-40°C ≦ Tamb ≦ 70°C (for model AIG-302-T-AP-AZU-LX, AIG-302- T-EU-AZU-LX, AIG-302-T-US-AZU-LX)

Rated Cable Temp ≧ 100 °C

Address of manufacturer: No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004, Taiwan

Specific Conditions of Use 

  • The equipment shall only be used in an area of at least pollution degree 2, as defined in EN 60664-1.
  • The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 under EN 60079-0 and is accessible only using a tool.

CAUTION
This device is an open-type device that is intended to be installed in an enclosure accessible only by a tool. The device is suitable for use in Class I, Division 2, Groups A, B, C, and D hazardous locations or non-hazardous locations.

WARNING

Explosion Hazard
Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations.

WARNING

Explosion Hazard
External connections (console port) should not be used in hazardous locations.

WARNING
Antennas intended for use in Class I Division 2 hazardous locations must be installed within the end-user enclosure. For remote mounting in an unclassified location, routing and installation of the antennas shall be per the National Electrical Code (NEC) requirements (NEC/CEC) Sec. 501.10(b).

WARNING
The USB, RS-232/422/485 serial ports, LAN1, LAN2, and console ports, and the reset button may only be accessed for equipment setup, installation, and maintenance in non-hazardous locations. These ports and their associated interconnecting cables shall remain inaccessible in hazardous locations.

BSMI Taiwan
Declaration of the Presence Condition of the Restricted Substances Marking.

MOXA-AIG-302-Series-Advanced-IIoT-Gateway-Fig- (30)

  • Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of the presence condition.
  • Note 2: “○” indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.
  • Note 3: The “-” indicates that the restricted substance corresponds to the exemption.

Technical Support Contact Information www.moxa.com/support. ©2024 Moxa Inc. All rights reserved.

Documents / Resources

MOXA AIG-302 Series Advanced IIoT Gateway [pdf] Installation Guide
AIG-302 Series Advanced IIoT Gateway, AIG-302 Series, Advanced IIoT Gateway, IIoT Gateway, Gateway

References

Leave a comment

Your email address will not be published. Required fields are marked *