MEAN WELL PPT-125 Series 125W Triple Output with PFC Function
Specifications:
- Model: PPT-125 series
- Output Power: 125W
- Input: Universal AC input / Full range
- Features: Built-in active PFC function, Short circuit / Overload / Over voltage protections, PWM control and regulated, High power density, LED indicator for power on, 100% full load burn-in test, 18CFM FAN, Compact size, 3 years warranty
- Certifications: AS/NZS62368-1, UL62368-1, BS EN/EN62368-1, IEC62368-1 TPTC004
Product Usage Instructions
Connection:
Connect the PPT-125 series power supply to a suitable AC power source using the provided universal AC input.
Output Configuration:
The PPT-125 series offers multiple output channels (CH1, CH2,CH3) with different voltage and current ratings. Ensure to connect your devices to the appropriate output channel based on your requirements.
Power On:
After connecting the power supply and configuring the output channels, turn on the power supply using the LED indicator for power on.
Safety Precautions:
Ensure the input voltage is within the specified range (90 ~ 264VAC) and frequency range (47~63Hz). Avoid overloading the power supply to prevent damage.
Frequently Asked Questions (FAQ):
Q: What is the warranty period for the PPT-125 series?
A: The PPT-125 series comes with a 3-year warranty.
Q: How can I check the GTIN code for my product?
A: You can use the MW Search tool at https://www.meanwell.com/serviceGTIN.aspx to find the GTIN code for your PPT-125 series unit.
125W Triple Output with PFC Function
PPT-125 series
Features
- Universal AC input / Full range
- Built-in active PFC function
- Protections: Short circuit / Overload / Over voltage
- PWM control and regulated
- High power density 6.117W/inch’
- LED indicator for power on
- 100% full load burn-in test
- 125W with 18CFM FAN
- 5″x3″ compact size
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | PPT-125A | PPT-125B | PPT-125C | PPT-125D | |||||||||
OUTPUT |
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 3.3V | 5V | 12V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 24V | 12V | |
RATED CURRENT | 10A | 8A | 0.5A | 11.5A | 3A | 0.5A | 11A | 2.5A | 0.5A | 7A | 2.5A | 0.5A | |
CURRENT RANGE (convection) | 1 ~ 10A | 0.8 ~ 8A | 0.05 ~ 0.5A | 1 ~ 11.5A | 0.3 ~ 3A | 0.05 ~ 0.5A | 1 ~ 11A | 0.25 ~ 2.5A | 0.05 ~ 0.5A | 1 ~ 7A | 0.25 ~ 2.5A | 0.05 ~ 0.5A | |
CURRENT RANGE (18CFM FAN) | 1 ~ 12.5A | 0.8 ~ 10A | 0.05 ~ 0.63A | 1 ~ 14.38A | 0.3 ~ 3.75A | 0.05 ~ 0.63A | 1 ~ 13.75A | 0.25 ~ 3.13A | 0.05 ~ 0.63A | 1 ~ 8.75A | 0.25 ~ 3.13A | 0.05 ~ 0.63A | |
RATED POWER (convection) | 79W | 99.5W | 100W | 101W | |||||||||
RATED POWER (18CFM FAN) | 98.81W | 124.46W | 125.15W | 126.43W | |||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 100mVp-p | 240mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | CH1:3.13 ~ 3.46V | CH1:4.75 ~ 5.25V | CH1:4.75 ~ 5.25V | CH1:4.75 ~ 5.25V | |||||||||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±5.0% | ±6.0% | ±3.0% | ±5.0% | ±6.0% | ±3.0% | ±5.0% | ±6.0% | ±3.0% | ±5.0% | ±6.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±3.0% | ±3.0% | ±5.0% | ±3.0% | ±3.0% | ±5.0% | ±3.0% | ±3.0% | ±5.0% | ±3.0% | ±3.0% | ±5.0% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 24ms/230VAC 24ms/115VAC at full load | ||||||||||||
INPUT |
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||||||||
FREQUENCY RANGE | 47~63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | ||||||||||||
EFFICIENCY (Typ.) | 75% | 78% | 78% | 78% | |||||||||
AC CURRENT (Typ.) | 1.7A/115VAC 0.75A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START 24A/230VAC | ||||||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||||||
PROTECTION |
OVERLOAD |
130 ~ 160% rated output power | |||||||||||
Protection type : Fold back current limiting, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE |
CH1:3.6 ~ 4.45V | CH1:5.75 ~ 6.75V | CH1:5.75 ~ 6.75V | CH1:5.75 ~ 6.75V | |||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
ENVIRONMENT |
WORKING TEMP., HUMIDITY | -20 ~ +70℃ (Refer to “Derating Curve”) | |||||||||||
WORKING TEMP. | 20 ~ 90% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1 , EAC TP TC 004 approved | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||||||||
OTHERS |
MTBF | 2173.4K hrs min. Telcordia SR-332 (Bellcore) ; 269.9K hrs min. MIL-HDBK-217F (25℃) | |||||||||||
DIMENSION | 127*76.2*34.6mm (L*W*H) | ||||||||||||
PACKING | 0.37Kg; 36pcs/14.3Kg/0.96CUFT | ||||||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Heat Sink HS1,HS2 & HS3 can not be shorted. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | AC/L |
JST VHR or equivalent |
JST SVH-21T-P1.1 or equivalent |
2 | No Pin | ||
3 | AC/N |
DC Output Connector (CN4) : JST B5P-VH*2 or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | CH3 |
JST VHR or equivalent |
JST SVH-21T-P1.1 or equivalent |
2,3 | CH2 | ||
4~8 | GND | ||
9,10 | CH1 |
: Grounding Required
- HS1,HS2 & HS3 cannot be shorted.
- M1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2 and chassis grounding.
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Documents / Resources
![]() |
MEAN WELL PPT-125 Series 125W Triple Output with PFC Function [pdf] Owner's Manual PPT-125A, PPT-125B, PPT-125C, PPT-125D, PPT-125 Series 125W Triple Output with PFC Function, PPT-125 Series, 125W Triple Output with PFC Function, Output with PFC Function, PFC Function |