MEAN-WELL-LOGO

MEAN WELL PPT-125 Series 125W Triple Output with PFC Function

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-PRODUCT

Specifications:

  • Model: PPT-125 series
  • Output Power: 125W
  • Input: Universal AC input / Full range
  • Features: Built-in active PFC function, Short circuit / Overload / Over voltage protections, PWM control and regulated, High power density, LED indicator for power on, 100% full load burn-in test, 18CFM FAN, Compact size, 3 years warranty
  • Certifications: AS/NZS62368-1, UL62368-1, BS EN/EN62368-1, IEC62368-1 TPTC004

Product Usage Instructions

Connection:
Connect the PPT-125 series power supply to a suitable AC power source using the provided universal AC input.

Output Configuration:
The PPT-125 series offers multiple output channels (CH1, CH2,CH3) with different voltage and current ratings. Ensure to connect your devices to the appropriate output channel based on your requirements.

Power On:
After connecting the power supply and configuring the output channels, turn on the power supply using the LED indicator for power on.

Safety Precautions:
Ensure the input voltage is within the specified range (90 ~ 264VAC) and frequency range (47~63Hz). Avoid overloading the power supply to prevent damage.

Frequently Asked Questions (FAQ):

Q: What is the warranty period for the PPT-125 series?
A: The PPT-125 series comes with a 3-year warranty.

Q: How can I check the GTIN code for my product?
A: You can use the MW Search tool at https://www.meanwell.com/serviceGTIN.aspx to find the GTIN code for your PPT-125 series unit.

125W Triple Output with PFC Function

PPT-125 series

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (1)

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • Protections: Short circuit / Overload / Over voltage
  • PWM control and regulated
  • High power density 6.117W/inch’
  • LED indicator for power on
  • 100% full load burn-in test
  • 125W with 18CFM FAN
  • 5″x3″ compact size
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL PPT-125A PPT-125B PPT-125C PPT-125D
 

 

 

 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC VOLTAGE 3.3V 5V 12V 5V 12V -12V 5V 15V -15V 5V 24V 12V
RATED CURRENT 10A 8A 0.5A 11.5A 3A 0.5A 11A 2.5A 0.5A 7A 2.5A 0.5A
CURRENT RANGE (convection) 1 ~ 10A 0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A 0.05 ~ 0.5A 1 ~ 11A 0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A 0.25 ~ 2.5A 0.05 ~ 0.5A
CURRENT RANGE (18CFM FAN) 1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A
RATED POWER (convection) 79W 99.5W 100W 101W
RATED POWER (18CFM FAN) 98.81W 124.46W 125.15W 126.43W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p
VOLTAGE ADJ. RANGE CH1:3.13 ~ 3.46V CH1:4.75 ~ 5.25V CH1:4.75 ~ 5.25V CH1:4.75 ~ 5.25V
VOLTAGE TOLERANCE Note.3 ±3.0% ±5.0% ±6.0% ±3.0% ±5.0% ±6.0% ±3.0% ±5.0% ±6.0% ±3.0% ±5.0% ±6.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±3.0% ±3.0% ±5.0% ±3.0% ±3.0% ±5.0% ±3.0% ±3.0% ±5.0% ±3.0% ±3.0% ±5.0%
SETUP, RISE TIME 1000ms, 30ms/230VAC            2000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 24ms/230VAC            24ms/115VAC at full load
 

 

 

 

INPUT

VOLTAGE RANGE 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE 47~63Hz
POWER FACTOR (Typ.) PF>0.93/230VAC            PF>0.98/115VAC at full load
EFFICIENCY (Typ.) 75% 78% 78% 78%
AC CURRENT (Typ.) 1.7A/115VAC            0.75A/230VAC
INRUSH CURRENT (Typ.) COLD START 24A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

 

OVERLOAD

130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
 

OVER VOLTAGE

CH1:3.6 ~ 4.45V CH1:5.75 ~ 6.75V CH1:5.75 ~ 6.75V CH1:5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP., HUMIDITY -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING TEMP. 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1 , EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
 

OTHERS

MTBF 2173.4K hrs min.       Telcordia SR-332 (Bellcore) ; 269.9K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 127*76.2*34.6mm (L*W*H)
PACKING 0.37Kg; 36pcs/14.3Kg/0.96CUFT
 

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

5.  Heat Sink HS1,HS2 & HS3 can not be shorted.

6.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (2)

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L  

JST VHR

or equivalent

 

JST SVH-21T-P1.1

or equivalent

2 No Pin
3 AC/N

DC Output Connector (CN4) : JST B5P-VH*2 or equivalent

Pin No. Assignment Mating Housing Terminal
1 CH3  

JST VHR

or equivalent

 

JST SVH-21T-P1.1

or equivalent

2,3 CH2
4~8 GND
9,10 CH1

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (3): Grounding Required

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (4)

  1. HS1,HS2 & HS3 cannot be shorted.
  2. M1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2 and chassis grounding.

Block Diagram

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (5)

Derating Curve

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (6)

Output Derating VS Input Voltage

MEAN-WELL-PPT-125-Series-125W-Triple-Output-with-PFC-Function-FIG- (7)