Inxpect SRE 100 Series Ethernet Fieldbus Control
Specifications
- Product Name: Inxpect SRE 100 Series, Inxpect SRE 200 Series
- Product Type: Safety Radar Equipment
- Certifications: CE conformity, UKCA conformity
- Intended Use: Human body detection systems certified SIL 2 according to IEC/EN 62061 and PL d according to EN ISO 13849-1
- Component Structure: Ruggedized control units with IP67 protection
Product Usage Instructions
Installation Instructions
- Ensure correct installation of the system by following the instructions provided in the manual.
- Avoid obstructing the sensor field of view with static objects, especially metallic objects, to maintain efficient sensor detection.
Certifications
Download all updated certifications from the official website: InxpectDownloads.
CE conformity and UKCA conformity are ensured for compliance with relevant directives and regulations.
Intended Use
The product functions as a human body detection system with specific safety functions:
- Access detection function: Deactivates safety outputs when one or more persons access a hazardous area to stop machinery parts.
- Restart prevention function: Prevents unexpected starting or restarting of machinery by keeping safety outputs deactivated upon motion detection in the dangerous area.
Component Structure
- The product includes ruggedized control units with Type B control units inside containers providing IP67 protection.
- Refer to the relevant manual for information on general functions and Type B control units not covered in this manual.
Models
The product is available in various models including C201B-RA-P, C201B-RA-F, C201B-RA-C, C202B-RA, and C203B-RA. Each model has specific control unit types and configurations.
Installation instructions
All rights reserved. Subject to change without notice.
- General warnings
- Wrong installation and configuration of the system decreaseor inhibit both the protective function of the system and the safety of the device. Follow the instructions provided in this document for correct installation of the system.
- The presence of static objects, in particular metallic objects, within the field of view may limit the efficiency of sensor detection. Keep the sensor field of view unobstructed.
Certifications
- All updated certifications can be downloaded from https://www.inxpect.com/en/downloads.
CE conformity
- The manufacturer, Inxpect SpA, states that Inxpect SRE 100 Series and Inxpect SRE 200 Series (Safety Radar Equipment) comply with the 2014/53/EU and 2006/42/EC directives. The full EU Declaration of Conformity text is available on the company’s website: https://www.inxpect.com/en/downloads.
UKCA conformity
- The manufacturer, Inxpect SpA, states that Inxpect SRE 100 Series and Inxpect SRE 200 Series (Safety Radar Equipment) comply with Radio Equipment Regulations 2017 and Supply of Machinery (Safety) Regulations 2008. The full UKCA Declaration of
- Conformity text is available on the company’s website: https://www.inxpect.com/en/downloads.
Intended use
- Both Inxpect Inxpect SRE 100 Series and Inxpect SRE 200 Series are human body detection systems, certified SIL 2 according to IEC/EN 62061 and PL d according to EN ISO 13849-1.
- They perform the following safety functions:
- Access detection function: access of one or more persons to a hazardous area deactivates the safety outputs to stop the moving parts of the machinery.
- Restart prevention function: prevents unexpected starting or restarting of the machinery. Detection of motion within the dangerous area maintains the safety outputs deactivated to prevent machinery starting.
Component structure
- The ruggedized control units
- The ruggedized control units are Type B control units that are incorporated inside a container which guarantees IP67 protection.
- For information on general functions and for instructions relating to Type B control units not included in this manual, see the manual relevant to the system you use.
Models
Ruggedized control unit | Control unit model | Control unit type |
C201B-RA-P | C201B | -P |
C201B-RA-F | C201B | -F |
C201B-RA-C | C201B | -C |
Ruggedized control unit | Control unit model | Control unit type |
C202B-RA | C202B | – |
C203B-RA | C203B | – |
Structure
Structure | ||
1 | 2 | 3 |
C201B-RA-P C201B-RA-F
C201B-RA-C |
C202B-RA | C203B-RA |
Label |
Function |
Description |
C201B-RA-P, C201B-RA-F, C201B-RA-C |
C202B-RA |
C203B-RA |
XE1 | CONFIG | Ethernet connector (M12, 4P, D-coded, female) | x | x | – |
XU1 | USB connector (mini-USB) | – | – | x | |
A | – | Pressure relief vent | x | x | x |
X1 | I/O | Outputs connector (M12, 8P, A-coded, female) | x | x | x |
X2 | Inputs connector (M12, 8P, A-coded, male) | x | x | x | |
XD1 | POWER | Power input connector (M12, 4P+PE, L-coded,
male) |
x | x | x |
XD2 | Power output connector (M12, 4P+PE, L-coded,
female) |
x | x | x | |
B | – | Power status LED (green) | x | x | x |
XF11 | SENSORS | Sensors connector (M12, 5P, A-coded, female) | x | x | x |
XF12 | Sensors connector (M12, 5P, A-coded, female) | x | x | x | |
XF1 | FIELDBUS | Fieldbus connector (M12, 4P, D-coded, female) | x | – | – |
XF2 | Fieldbus connector (M12, 4P, D-coded, female) | x | – | – |
- SRE 100 Series sensors
Part | Description |
A | Sensor |
B | Screws for fastening the sensor at a specific inclination |
C | Mounting bracket |
D | Status LED |
E | Connectors for connecting the sensors in a chain and to the control unit |
- SRE 100 Series sensor status LED
Status | Meaning |
Steady on | Sensor is working. No motion detected. |
Rapid flashing on (100 ms) | Sensor is detecting motion. Not available if the sensor is in muting. |
Other conditions | Error |
- SRE 200 Series sensors
Part | Description |
A | Sensor |
B | Status LED |
C | Tamper-proof screws to position the sensor at a specific angle around x-axis (tilt 10° steps) |
D | Mounting bracket |
E | Tamper-proof screw to position the sensor at a specific angle around y-axis (pan 10° steps) |
F | Connectors for connecting the sensors in a chain and to the control unit |
G | Tamper-proof screw to position the sensor at a specific angle around z-axis (roll 10° steps) |
- SRE 200 Series sensor status LED
Status | Meaning |
Steady blue | Sensor is working. No motion detected. |
Flashing blue | Sensor is detecting motion*. Not available if the sensor is in muting.
For restart prevention function, the LED keeps flashing for about 2 seconds after the end of a detection |
Purple | Firmware update conditions |
Red | Error conditions |
Connector pin-outs
- Ethernet (XE1) and Fieldbus (XF1/XF2) connectors
Pin | Function |
1 | TX+ |
2 | RX+ |
3 | TX- |
4 | RX- |
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
- Note: the XE1 connector cap is included for C201B-RA and C202B-RA control units.
Mini-USB connector, mini-B type (XU1)
Pin | Function |
1 | V cc (+5 V dc) |
2 | D- |
3 | D+ |
4 | ID |
5 | GND |
- Note: the connector cap is included for the C203B-RA control unit
Outputs connector (X1)
Pin | Function |
1 | OUTPUT 1 |
2 | GND, common reference for all the digital outputs |
3 | OUTPUT 2 |
4 | GND, common reference for all the digital outputs |
Pin | Function |
5 | OUTPUT 3 |
6 | GND, common reference for all the digital outputs |
7 | OUTPUT 4 |
8 | GND, common reference for all the digital outputs |
- Note: the cables used must have a maximum length of 30 m (98.4 ft).
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
Inputs connector (X2)
Pin | Function |
1 | VOUT (+24 V dc)* |
2 | INPUT 1 |
3 | VOUT (+24 V dc)* |
4 | INPUT 2 |
5 | VOUT (+24 V dc)* |
6 | INPUT 3 |
7 | VOUT (+24 V dc)* |
8 | INPUT 4 |
- Note: VOUT (+24 V dc) is useful when a free contact is connected to the input (see following example).
- Note: the connector cap is included
Example of free contact connected to the input
Voltage and current limits for digital inputs
- The digital inputs (input voltage 24 V DC) adhere to the following voltage and current limits, in accordance with standard IEC/EN 61131-2:2003
Type 3 | |
Voltage limits | |
0 | from – 3 to 11 V |
1 | from 11 to 30 V |
Current limits | |
0 | 15 mA |
1 | from 2 to 15 mA |
Power input connector (XD1)
Pin | Function |
1 | VIN (+24 V dc)* |
2 | GND |
3 | GND |
4 | VIN (+24 V dc)* |
PE | Earth |
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
- Note: pin 1 and pin 4 have the same meaning to guarantee bigger sections of (incoming) power supply for long routes
Power output connector (XD2)
Pin | Function |
1 | VOUT (+24 V dc)* |
2 | GND |
3 | GND |
4 | VOUT (+24 V dc)* |
PE | Earth |
- Note: the cables used must have a maximum length of 30 m (98.4 ft).
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
- Note*: pin 1 and pin 4 have the same meaning to guarantee bigger section of (outgoing) power supply. For multiple control units in a chain, it is suggested to not exceed the number of 4 control units.
- Note: the connector cap is included
Sensors connector (XF11/XF12)
Pin | Function |
1 | SHIELD |
2 | +12 V dc output |
3 | GND |
4 | CAN H |
5 | CAN L |
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
Sensor M12 CAN bus connectors
Pin | Function |
1 | Shield |
2 | +12 V dc |
3 | GND |
4 | CAN H |
5 | CAN L |
- Note: screw the external connector or cap with a torque of 0.6 Nm (5.3 lbs in).
Technical data
Outputs | Configurable as follows:
4 Output Signal Switching Devices (OSSDs) (used as single channels) 2 dual channel safety outputs 1 dual channel safety output and 2 Output Signal Switching Devices (OSSDs) |
OSSD characteristic | Maximum resistive load: 100 KΩ
Minimum resistive load: 70 Ω Maximum capacitive load: 1000 nF Minimum capacitive load: 10 nF |
Safety outputs | High-side outputs (with extended protection function)
Maximum power: 11.2 W Maximum total current (sum of all the OSSDs): 0.4 A The OSSDs provide what follows: ON-state: from Uv-1V to Uv (Uv = 24V +/- 4V) OFF-state: from 0 V to 2.5 V r.m.s. |
Inputs | Configurable as follows:
4 single channel (cat. 2) type 3 digital inputs with common GND 2 dual channel (cat. 3) type 3 digital inputs with common GND 1 dual channel (cat. 3) and 2 single channels (cat. 2) type 3 digital inputs with common GND See Voltage and current limits for digital inputs. |
Fieldbus interface (if available) | Ethernet based interface with different standard Fieldbus |
Power supply | 24 V DC (20–28 V DC) *
Maximum current: 1 A (Inxpect SRE 100 Series) Maximum current: 1.2 A (Inxpect SRE 200 Series) |
Consumption | Max. 5 W |
Assembly | Fixed by screws |
Weight | 1260 g |
Screws | Stainless steel |
Gasket | Silicone |
Cover | Diecast aluminium ADC12 |
Main body | Extruded aluminium A6063S-T5 |
Degree of protection | IP67 |
Terminals | Section: 1 mm2 (16 AWG) max.
Maximum current: 4 A with 1 mm2 cables (16 AWG) |
Altitude | Max. 1500 m ASL |
Pollution degree | 2 |
Overvoltage category | II |
Operating temperature | From -30 to +50 °C (from -22 to +122 °F) |
Storage temperature | From -40 to +80 °C (from -40 to +176 °F) |
- Note*: the unit shall be supplied by an isolated power source which complies with the standard IEC/EN 60204-1 and fulfils the requirements of
- Limited-Energy Circuit in accordance with IEC/UL/CSA 61010-1/ IEC/UL/CSA 61010-2-201 or
- Limited Power Source (LPS) in accordance with IEC/UL/CSA 60950-1 or
- (For North America and/or Canada only) a Class 2 supply source which complies with the National
- Electrical Code (NEC), NFPA 70, Clause 725.121 and Canadian Electrical Code (CEC), Part I, C22.1. (typical examples are a Class 2 transformer or a Class 2 power sources in compliance with, UL 5085- 3/ CSA-C22.2 No. 66.3 or UL 1310/CSA-C22.2 No. 223).
Installation
Materials required
- Two M4 tamper-proof screws to mount each sensor.
- Cables to connect the control unit to the first sensor and the sensors to one another.
- Depending on the model, a data USB cable (product code X0000012) or an Ethernet cable (product code X0000013) to connect the control unit to the computer.
- Four M4 fixing screws for the slots of the ruggedized control unit.
- Two bus terminators (product code: 07000003) with resistance of 120 Ω.
- A screwdriver for tamper-proof screws to be used with the Hex pin security bit supplied in the control unit package.
- (only for SRE 100 Series sensors) If necessary, to protect the sensor and to prevent reflections from generating undesired alarms, one Metal protector kit (product code: 90202ZAA) per sensor. See the instructions supplied with the kit for installation instructions.
- Note: the Metal protector kit is particularly recommended if the sensor is installed on parts that are moving, vibrating or that are near vibrating parts.
Operating system required
- Microsoft Windows 10 or later
- Apple OS X 11.0 or later
- Install the ruggedized control unit
- Fix the control unit using four screws (not included) and connect to external equipment.
- Power-up the control unit using the power input connector XD1, and make all the other required electrical connections with external equipment (see Connector pin-outs).
- NOTICE: the SNS input “V+ (SNS)” and the GND input “V- (SNS)” are already connected inside the control unit.
- NOTICE: when powered, the system takes about 2 s (for Inxpect SRE 100 Series) and 20 s (for Inxpect SRE 200 Series) to start.During that period, the outputs and the diagnostic functions are deactivated, and the green sensor status LEDs of the connected sensors inside the control unitflash.
- NOTICE: make sure to avoid any EMC interference during the control unit installation.
- Install SRE 100 Series sensors
- Note: for installation with Metal protector kit (product code 90202ZAA), see the instructions supplied with
the kit.
Note: the usage of a thread-locking fluid on the threads of fasteners is suggested, especially when the sensor is installed on a moving or vibrating part of the machinery.
Note: if the sensor is installed on parts that vibrate and objects are present in the field of view, the sensor could generate undesired alarms.
- Position the sensor as indicated in the configuration report and fasten the bracket with two M4 tamper-proof screws.
- NOTICE: make sure the support does not inhibit machinery commands.
- Loosen the side screws to tilt the sensor.
- Tilt the sensor to the desired inclination.
Note: a notch is equal to a 10° of inclination.
- Tighten the screws.
Install SRE 200 Series sensors
- Note: the usage of a thread-locking fluid on the threads of fasteners is suggested, especially when the sensor is installed on a moving or vibrating part of the machinery.
- Note: if no bracket is used for sensor installation, use tamper-proof screws and threadlocker.
- Position the sensor as indicated in the configuration report and fasten the bracket with two M4 tamper-proof screws directly onto the floor or another support.
- NOTICE: make sure the support does not inhibit machinery commands.
- With an Allen key, loosen the screw at the bottom to pan the sensor.
Note: to avoid damaging the bracket, loosen the screw completely before panning the sensor.
- Pan the sensor until it reaches the desired position.
- Note: a notch is equal to a 10° of rotation.
- Tighten the screw
- Loosen the tamper-proof screws to tilt the sensor.
- Tilt the sensor to the desired inclination.
- Note: a notch is equal to a 10° of inclination. For a finer regulation of the sensor inclination with a 1° precision (see Inxpect SRE 200 Series Instruction manual).
- Tighten the screws.
- (optional and only for SRE 200 Series sensors) Mount 3-axis bracket
- The bracket that allows rotation around the z-axis (roll) is an accessory in the package. To mount it:
- Unscrew the screw at the bottom and remove the bracket with the sensor and the aligning ring.
- Attach the roll bracket to the base. Use the tamper-proof screw provided with the bracket.
- Mount the bracket with the sensor and the aligning ring. Use the tamper-proof screw provided with the bracket.
Connect the sensors to the ruggedized control unit
- Note: the total maximum length of the CAN bus line is 30 m (98.4 ft) for Inxpect SRE 100 Series and 80 m (262.5 ft) for Inxpect SRE 200 Series.
- Note: the DIP switch on the control unit is already in OFF position (bus terminator resistance excluded): there is no need to include it.
- Chain with control unit at the end of the chain and a sensor with termination connector
- Chain with control unit inside of the chain and two sensors with termination connector
Insert the bus terminators
- Insert two bus terminators (product code: 07000003) as follows
If… | Then… |
the control unit is at the end of the chain | insert one bus terminator into the free connector of the last sensor of the chain and the other one into the free connector of the ruggedized control unit. |
the control unit is inside the chain | insert one bus terminator into the free connector of the two last sensors of the chain. |
SAFTEY INFORMATION
- Note: if the installation fails, the dependencies needed by the application may be missing. Update your operating system or contact our Technical Support to receive assistance
- Download the application from the https://tools.inxpect.com website and install it on the computer.
- With Microsoft Windows operating system, download and install from the same site also the driver for USB connection
Start the application
- Connect the control unit to the computer using a data USB cable with a mini-USB connector or the Ethernet cable (if an Ethernet port is available).
- Supply power to the control unit.
- Start the Inxpect Safety application.
- Configure the system (see Instruction manual).
- What to do next
Follow the instructions in the manual to configure the system, validate the safety functions and manage the configuration - https://tools.inxpect.com
- How to return the product
- To return the product, it is suggested to send the whole ruggedized control unit to the local distributor or exclusive distributor
- When to open the ruggedized control unit
- NOTICE: make sure only skilled personnel open the control unit.
List of the cases
- The control unit should be opened only in the following cases:
- perform the SD Restore*. To know the procedure, see the relevant manual.
- replace the SD card*. To know the procedure, see the relevant manual.
- check the status of the LEDs. To know the meaning of the LEDS, see the relevant manual.
- Note*: the SD card is included and already insterted.
- To open the control unit and have details about the internal connections, please follow the instructions in the relative document downloadable from Inxpect Tools (https://tools.inxpect.com/).
Planned maintenance
Product | Part number |
USB cable | X0000012 |
Ethernet cable | X0000013 |
XD1, X2 connector cap | X0000014 |
XD2 connector cap | X0000015 |
XF1, XF2, X1, XE1, XF11 and
XF12 connector cap |
X0000016 |
XU1 connector cap | X0000017 |
FAQs
Q: Can I install the system without referring to the manual?
A: It is highly recommended to follow the installation instructions provided in the manual to ensure correct installation and configuration for optimal system performance and safety.
Q: How can I obtain updated certifications for the product?
A: You can download all updated certifications from the official Inxpect website at https://www.inxpect.com/en/downloads.