CEG Series Standard Convector
“
Product Specifications:
- Product Name: Convector CEG Series
- Power Supply: Electric
- Installation: Surface Wall Mounting
- Recommended Clearance: 4 inches (102 mm) below heater base to
floor - Safety Features: Not recommended with ground fault circuit
interrupter (GFCI)
Product Usage Instructions:
Installation:
- Ensure installation is done by a qualified person where
required by law. - Locate power supply leads behind the planned location of the
heater. - Ensure minimum clearance of 4 inches (102 mm) below the heater
base to the floor. - Provide minimum clearance of 4 inches (102 mm) between the
sides of the heater and adjacent walls.
Important Instructions:
- Read all instructions before installing or using the
heater. - Avoid direct skin contact with hot surfaces to prevent
burns. - Keep combustible materials at least 36 inches (915 mm) away
from the heater. - Exercise caution when children or invalids are near the
heater. - If the heater malfunctions, disconnect power and have it
inspected by a qualified electrician. - Do not operate the heater outdoors.
- Ensure proper electrical connections and grounding for
safety.
Operation:
- Place the bottom T slots in the base for support and clip the
upper side of the body in the upper U shape part of the
support. - Avoid contact between the supply wire and the back of the
heater or any other object. - Turn on the main power after completing connections.
Frequently Asked Questions (FAQ):
Q: Can this heater be used outdoors?
A: No, this heater is not intended for outdoor use.
Q: What should I do if the heater malfunctions?
A: Disconnect power at the service panel and have the heater
inspected by a qualified electrician before reusing it.
Q: Is it necessary to ground the heater during
installation?
A: Yes, ensure to connect the green wire to the ground wire for
safe operation.
“`
1 800 463-7043 · www.globalcommander.ca
INSTALLATION INSTRUCTIONS Convector “CEG” Series
WARNING
When using electrical appliances, basic precautions should always be taken to reduce the risk of fire, electrical shock and injury, including the following.
INSTALLATION INSTRUCTIONS
The installation of this heater must be executed by a qualified person, where required by law.
CAUTION: – Use supply wires suitable for 90 °C (194 °F). – For bathroom use, the heater must be installed so that switches
and other controls cannot be touched by anyone in the bath or shower. – This product is not recommended with the ground fault circuit interrupter (GFCI). The humidity in the air can generate a leakage current higher than the limit of the GFCI which will cause the product to stop.
Read carefully these instructions before installation, operation of the SURFACE WALL MOUNTING;
heater. Failure to adhere to the instructions could result in fire, electric 1- Locate approximately the power supply leads behind the
shock, serious personal injury, and death or property damage. Review
planned location of the heater. Recommended clearance below
frequently for continuing safe operation and instruction of future users,
heater base to floor is 4 in. (102 mm) minimum. Allow 4 in.
if necessary.
(102 mm) minimum clearance between sides of heater and
IMPORTANT INSTRUCTIONS
1- Read all instructions before installing or using this heater. 2- This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, like furniture, pillows, bedding, papers, clothes, and curtains at least 36 in. (915 mm) from the front of the heater and away from the sides.
any adjacent walls. The leads shall be at the right of the wall bracket. 2- Lean the bottom of the wall bracket on the floor and mark with a pencil the height desired (of the heater bottom) using the wholes with inches written on the side. 3- Secure wall bracket with the 4 screws supplied. The bottom of the key holes shall be in line with the previous marks. Triangle mark on horizontal bar is the center of the heater. Before installing wall support, align center of heater with support center mark and make sure the heater sides are at least 4 in.
3- Extreme caution is necessary when any heater is used by or near
(102 mm) from any adjacent walls.
children or invalids and whenever the heater is left operating and 4- Untighten wire holder (for Loomex cable) and make electrical
unattended.
connections by having the heater the nearest possible to the
4- Do not operate any heater after it malfunctions. Disconnect power
electrical wire. For BX cable, remove one of the two knock-
at service panel and have heater inspected by a qualified electrician
outs, install a connector (not furnished) and have 6 to 8 in.
before reusing.
(15 to 20 cm) of free wire and get them out of the hole of the
5- Do not use outdoors.
wire holder in order to make connections from outside. Do not
6- To disconnect heater, turn off power to heater circuit at main disconnect
forget to connect the green wire to ground wire in order to have
panel.
a safe grounded heater.
7- Do not insert or allow foreign objects to enter any exhaust opening as 5- Once connections completed, place bottom T slots in the base
this may cause an electric shock or fire, or damage the heater. 8- Do not block air intakes or exhaust in any way whatsoever. 9- This heater has hot and arcing or sparking parts inside. Do not use it in
areas where gasoline, paint, or flammable liquids are used or stored. 10- Use this heater only as described in this manual. Any other use not
part of support, and clip the upper side of the body in the upper
U shape part of the support. 6- Do not let the excess of the supply wire come in contact with
the back of the heater, as well as any other object. 7- Put the main power on.
recommended by the manufacturer may cause fire, electric shock, or injury. 11- The heater has been designed and certified for ambient heating only. The maximum ambient operating temperature is 30 °C (86 °F). 12- The heater is not designed for use in a humid environment where condensation may form on the device.
CAUTION: – High temperature, risk of fire, keep electrical cords, drapery,
furnishings, and other combustibles at least 36 in. (915 mm) from the front of the heater and away from the sides. To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.
13- AMERICAN VERSION ONLY: Some models (up to 240V) include – In addition to ensuring that the clearance distances set out above
a visual alarm to warn that parts of the heater are getting excessively are respected, ensure that the framing materials, insulation and
hot. If the light turns on, immediately turn the heater off and inspect
finishing which are likely to be in contact with or close to the
for any objects on or adjacent to the heater that may have blocked device can withstand temperatures of at least 90 °C (194 °F).
the airflow or otherwise caused high temperatures to have occured. If no obstruction is visible, the heater must be checked by a qualified person. DO NOT OPERATE THE HEATER WITH THE ALARM
IMPORTANT
Do not obstruct the front of the heater for at least 48 in. (1200 mm).
LIGHT IS ON.
OPTIONS:
14- The thermostat should not be considered an infallible device in cases All heating equipment and options must be installed in accordance
where maintaining a temperature is considered critical. Examples: with local and national codes.
Hazardous material storage, computer server room, etc. In these Built-in relay:
particular cases, it is imperative to add a monitoring system to avoid – Refer to the diagram included with the relay option for
the consequences of a thermostat failure.
connections.
– Refer to instructions supplied with the option for mounting.
SAVE THESE INSTRUCTIONS INS420-201402-06
OPERATING INSTRUCTIONS
– The heater must be properly installed before it is used. – Turn the power on at the circuit breaker panel. – Electronic thermostat: Set the thermostat temperature at the
wanted room temperature.
CONTROL:
Model with built-in electronic thermostat: The electronic thermostat shall keep the room temperature in a range of ± 1 °C (± 2 °F) unless the room is not well insulated or the heater is too or not enough powerful for the room.
Model without control: Maintain room temperature by a line-voltage wall thermostat approved for residential heating. Even if it is not mandatory, an electronic thermostat gives better performance than a conventional thermostat.
MAINTENANCE INSTRUCTIONS
1- Once a year, remove the front panel and use a vacuum cleaner to remove the dust accumulation inside the heater and through openings of the front panel.
2- Cleaning should be done while the heater is disconnected from the main service panel. Wait until the housing and heating element cool before performing maintenance.
3- Replace the front panel before energizing. 4- Any other servicing should be performed by a qualified
technician.
WARRANTY
Please refer to the specification sheet at www.globalcommander.ca.
1
TOP HAUT
2
TOP HAUT
Wiring Diagram: Model with built-in
L1
THERMOSTAT
L2
electronic thermostat
L1 Load 1 Load 2 L2
8
8
7
7
6
6
5
5
4
Mark
4
the height
American version only up to 240V
desired
DETAIL A
CENTRE HAUT – TOP
Center mark
3 Center
Wiring Diagram: Model without control
American version only up to 240V
4
8 7
A
8 7
6
6
5
5
4
4
4” (102 mm) minimum
4” (102 mm) minimum
4” (102 mm) minimum
L1 L2/N
5
Documents / Resources
![]() |
Global Commander CEG Series Standard Convector [pdf] Installation Guide INS420-201402-06, 5adc9a18-ddf2-4d2f-af27-99ed44226eaa, CEG Series Standard Convector, CEG Series, Standard Convector, Convector |