FSP iFP Series 400VA-2000VA Line Interactive UPS User Manual

iFP Series 400VA-2000VA Line Interactive UPS

Specifications

  • Model: iFP 400VA~2KVA
  • Power Output: 400VA to 2000VA
  • Input Voltage: 220/230/240V AC
  • Input Voltage Range: 140-290V AC
  • Output Voltage: 220/230/240V AC
  • Battery Type: 12V/4.5Ah to 12V/9Ah
  • Number of Outlets: 4 to 6
  • Efficiency: Up to 90%
  • Dimensions: Vary based on model
  • Weight: Vary based on model

Product Usage Instructions

UPS Power On

When the UPS is powered on, it will enter a mode for 4
seconds.

AC Mode

When in AC mode, the UPS will provide Automatic Voltage
Regulation (AVR). The LCD will display information in the following
order when touched: 1. Output voltage 2. Input voltage 3. Load
level 4. Battery capacity.

Overload in AC Mode

When an overload occurs in AC mode, an icon will flash, and an
alarm will beep every 0.5 second.

Battery Mode

When in battery mode, the UPS will switch to battery power. When
the battery level is low, an icon will flash. An alarm will beep
every 10 seconds, and the LCD will display information in the
following order when touched: 1. Output voltage 2. Input voltage 3.
Load level 4. Battery capacity.

Overload in Battery Mode

If an overload occurs in battery mode, an icon will flash, and
an alarm will beep every 0.5 second.

FAQs

Q: What are the different models available?

A: The available models are iFP400, iFP650, iFP800, iFP1000,
iFP1500, and iFP2000.

Q: What are the key features of the product?

A: The key features include Automatic Voltage Regulation (AVR),
LCD display, multiple outlets, and battery backup.

Q: How do I know when the UPS is overloaded?

A: An overload is indicated by a flashing icon and audible
alarms at specified intervals.

“`

RU

FSP Manual Guide

– iFP 400VA~2KVA

·

:

&

·

,

. ,

.

·

.

.

6

.

·

.

·

: , ,

.

·

:

.

.

/

·

,

,

. ,

,

.

UPS

LCD

mode

Description

UPS Power on

When UPS is powered on, it will enter this mode for 4 seconds.

AC Mode
AVR , .

LCD information will be displayed in the following order when LCD is touched. 1.Output voltage 2.Input voltage 3.Load level 4.Battery capacity

Overload in AC mode

icon will flash.

When overload occurs, alarm will beep every 0.5 second.

Battery Mode

Overload in battery mode

When battery level is low, icon will flash.
icon will flash.

Alarm will beep every 10 seconds and LCD information will be displayed in the following order when LCD is touched. 1.Output voltage 2.Input voltage 3.Load level 4.Battery capacity
When overload occurs, alarm will beep every 0.5 second.

: .

:

.
.

400-800VA

.

1000VA

.
. .

1500-2000VA

­ .

A: B: C: / D: USB- () E: ()

RU

FSP Manual Guide

iFP 400VA~2KVA

·

,

.

. ,

.

.

·

«»

.

·

, ,

.

·

,

3.5 .

·

,

,

.

·

­

“OFF”

.

·

.

·

.

·

(

,

).

.

·

.

·

.

·

, ,

, .

·

,

.

·

.

·

.

:

1) ,

.

2) .

3) .

4)

.

5)

.

·

12

. , -, 6-

.

·

, –

– .

·

.

. .

·

,

.

.

·

!!! .

,

.

.

·

,

.

·

.

.

.

.
. .

.
6 . .
.

6 . . , . .

400VA/650VA/800VA

iFP400

iFP 650

iFP 800

400VA/

650VA/

800VA/

240W

360W

480W

220/230/240 AC

140-290 AC

± 10%( )

2-6

12V/4.5Ah

12V/7

12V/9

1

1

1

4 90%

()

300 x 101 x 142

()

3.55

4.25

4.9

0-90% RH @ 0-40°C ( )

40

*

.

1000VA/1500VA/2000VA

iFP 1000

iFP 1500

iFP 2000

1000VA/

1500VA/

2000VA/

600W

900W

1200W

220/230/240 AC

140-290 AC

± 10%( )

2-6

12V/7

12V/9

12V/9

2

2

2

4-6 90%

()

320 x 130 x 182

()

8.2

10.4

11

0-90% RH @ 0-40°C ( )

40

*

UA

FSP Manual Guide

– iFP 400VA~2KVA

·

:

&

·

, .

,

.

·

‘ .

.

6

..

·

.

·

: , ,

.

·

:

.

.

/

·

,

,

. ,

,

.

_

UPS Power on

, 4 .

AC Mode

AVR ,
.

– , -. 1. 2. 3. 4.

Overload in AC mode
Battery Mode

Overload in battery mode

, .
.

, 0,5 .
10 , – , -. 1.
2. 3. 4. , 0,5 .

: –

.

400-800VA

:

.
.

.

1000VA

.
.

A: B: C: /
D: USB- () E: ()

1500-2000VA

.

– .

UA

FSP Manual Guide

iFP 400VA~2KVA

·

,

. .

,

.

.

, «»

.

·

, ,

.

·

,

3.5 .

·

,

,

.

·

“OFF”

.

·

.

·

.

·

( ,

).

.

·

.

·

.

·

,

, , .

·

,

.

·

.

.

:

3) ,

.

4) .

5) .

6)

.

7)

.

·

12

. , -, 6- .

·

, –

– .

·

. .

.

·

,

.

.

!!! .

‘ ,

.

.

·

,

.

·

.

.

.

. .

.
6 . .
.

6 . . ‘ , . .

400VA/650VA/800VA

iFP400

iFP 650

400VA/

650VA/

240W

360W

220/230/240 AC

140-290 AC

iFP 800
800VA/ 480W

± 10%( )

2-6

12V/4.5Ah

12V/7Ah

12V/9Ah

1

1

1

4 90%

()

300 x 101 x 142

()

3.55

4.25

4.9

0-90% RH @ 0-40°C ( )

40

* .

1000VA/1500VA/2000VA

iFP 1000

1000VA/

600W

iFP 1500 1500VA/
900W 220/230/240 AC
140-290 AC

iFP 2000
2000VA/ 1200W

± 10%( )

2-6

12V/7 Ah

12V/9 Ah

12V/9 Ah

2

2

2

4-6 90%

()

320 x 130 x 182

()

8.2

10.4

11

0-90% RH @ 0-40°C ( )

40

* .

User Manual

Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA

INSTALLATION & OPERATION

Inspection

Plug in Equipment

The following items are inside the box: UPS unit User manual
Remove the UPS from its package and inspect it for damage that may have occurred during shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.

Plug your equipment to Battery Backup Outlets on the rear panel of
the UPS. NOTE: Make sure that the UPS is powered on to protect all important devices from data loss during power failure. CAUTION: NEVER connect a laser printer or scanner to the battery backup outlets of UPS. The equipment may draw

Connect to Utility Power

significantly power to overload the UPS.

Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best result, charge the battery for 6 hours prior to initial use.

Connect Com. Port and Install Software
(only for the model with USB port) Connect one end of the USB cable to PC and the other to the USB

Connect Modem/Phone Line
(only for the model with RJ-11 port) This UPS protects a single line (1 in/1 out) phone, modem, or fax machine from surges when connected through the UPS. Plug in

port at the rear of the UPS. Download the latest version of ViewPower software from http://www.power-software-download.com to your hard drive. Follow on-screen instructions to complete the software installation.

conning Internet line into the “IN” socket. Use one more Internet line cable in the “OUT” socket and plug one other end to the modem input socket.
REAR PANEL

LCD DISPLAY

Operation Display

UPS Mode

LCD

UPS

Description When UPS is powered

400VA/650VA/800VA

Power on

on, it will enter this mode for 4 seconds.

AC Mode

LCD information will be

displayed in the following

order when LCD is

touched.

1. Output voltage

When AVR is

2. Input voltage

functioning, icon will 3. Load level

flash every second.

4. Battery capacity

Overload

When overload occurs,

in AC

alarm will beep every 0.5

mode

icon will flash.

second.

Battery

Alarm will beep every 10

1000VA

Mode

seconds and LCD information will be

displayed in the following

order when LCD is

When battery level is low, icon will flash.

touched. 1. Output voltage 2. Input voltage

3. Load level

4. Battery capacity

1500VA/2000VA

Overload in battery

When overload occurs, alarm will beep every 0.5

mode

icon will flash.

second.

NOTE: If backlight shuts off, you may activate it by touching the

screen.

Fault Code Table:

Fault condition

LCD

Solutions

Output short

Disconnect short-circuited loads

A. Battery backup outlets: B. AC input

circuited Overload fault

and restart the UPS again.
Disconnect all output loads and restart the UPS again.

C. Fuse/Circuit breaker (option)

Overcharge

Call for service immediately.

D. USB com. port (option) E. Modem/Phone line surge protection (option) F. Cooling fan (only for 1500/2000 models)

Bad or severely

Please replace the battery.

discharged battery

High output voltage

Call for service immediately.

fault

Over-temperature

1. Turn off the unit and wait for

cooling.

2. Or remove excessive loads

and wait for cooling.

If fault alarm occurs, please call for service immediately.

User Manual

Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA

SAFETY CAUTION

SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.

This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS. Do not dispose of batteries in a fire as they may explode.
SPECIFICATIONS

MODEL
CAPACITY Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time

400

650

800

400VA/240W 650VA/360W 800VA/480W 220/230/240 VAC 162-290 VAC

± 10 % (Bat. mode)

Typical 2-6 ms

A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or
disconnecting batteries terminal.
6) Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.
TROUBLESHOOTING

Waveform

Simulated Sine Wave

Battery Type & No Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level

12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1

6 hours recover to 90% capacity

300 x 101 x 142 mm

3.7

4.4

5

0-90% RH @ 0-40°C non-condensing)

Less than 40dB

Problem
Nothing is displayed on LCD panel.

Possible Cause

Solutions

The UPS is not on. Press the power switch

again to turn on the UPS.

Battery voltage is too Charge the battery at least

low.

6 hours.

Battery fault.

Replace the battery.

MODEL CAPACITY

1000

1500

2000

1KVA/600W 1.5KVA/900W 2KVA/1200W

The UPS

Power cord loose.

always on

battery mode.

Re-plug the power cord.

Input Voltage
Input Voltage Range Output Voltage Regulation Transfer Time
Waveform

220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms Simulated Sine Wave

The UPS continuously beeps.
Backup time too short.

Please check the fault Please check the fault code code for the details. for the details.

Battery voltage is too Charge the battery at least

low.

6 hours.

Battery Type & No

12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2

Overload.

Remove some unnecessary

Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level

6 hours recover to 90% capacity

320 x 130 x 182

8.2

10.4

11

0-90% RH @ 0-40°C non-condensing)

Less than 40dB

*Specifications are subject to change without notice.

loads. Before reconnecting

equipment, please verify

that the load matches the

UPS capability specified in

the specs.

Battery defect.

Replace the battery.

If any abnormal situations occur that are not listed above, please call for service immediately.

User Manual

Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA

INSTALLATION & OPERATION

:

UPS

UPS : UPS

UPS : UPS

UPS 6
/

UPS

( USB ) USB PC UPS USB http://www.power-software-download.com
ViewPower

( RJ-11 port ) UPS UPS 1 1

LCD DISPLAY

Internet ” IN”

” OUT” Internet

UPS UPS

LCD

UPS

4

REAR PANEL
400VA/650VA/800VA

AC
AC

When AVR is
functioning, icon will flash every second.

LCD LCD 1. 2. 3. 4.
0.5

1000VA

icon will flash.
When battery level is low, icon will flash.

10 LCD
1. 2. 3. 4. 0.5

1500VA/2000VA

icon will flash.

: .

:

LCD

UPS

UPS

A.:
B.
C./ ()
D.USB ()
E./ () F. ( 1500/2000 )

1.

2.

User Manual

Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA

SAFETY CAUTION

– UPS

UPS

UPS UPS UPS
3.5mA
“”
UPS UPS

UPS UPS UPS
UPS
SPECIFICATIONS

MODEL
CAPACITY Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time Waveform Battery Type & No Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level

400

650

800

400VA/240W 650VA/360W 800VA/480W 220/230/240 VAC 162-290 VAC

± 10 % (Bat. mode)

Typical 2-6 ms

Simulated Sine Wave

12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1

6 hours recover to 90% capacity

300 x 101 x 142 mm

3.7

4.4

5

0-90% RH @ 0-40°C non-condensing)

Less than 40dB

MODEL

1000

1500

2000

CAPACITY
Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time
Waveform
Battery Type & No

1KVA/600W 1.5KVA/900W 2KVA/1200W 220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms Simulated Sine Wave 12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2

Charging Time Dimension (DxWxH)

6 hours recover to 90% capacity 320 x 130 x 182

Net Weight (kgs)

8.2

10.4

11

Humidity Noise Level

0-90% RH @ 0-40°C non-condensing) Less than 40dB

*

1) 2 3 4 5 6

12VDC 6

UPS UPS UPS UPS : C2 UPS

TROUBLESHOOTING

LCD UPS

UPS

6

UPS .

UPS

6

UPS

Documents / Resources

FSP iFP Series 400VA-2000VA Line Interactive UPS [pdf] User Manual
iFP Series, iFP Series 400VA-2000VA Line Interactive UPS, 400VA-2000VA Line Interactive UPS, Line Interactive UPS, Interactive UPS

References

Leave a comment

Your email address will not be published. Required fields are marked *