iFP Series 400VA-2000VA Line Interactive UPS
“
Specifications
- Model: iFP 400VA~2KVA
- Power Output: 400VA to 2000VA
- Input Voltage: 220/230/240V AC
- Input Voltage Range: 140-290V AC
- Output Voltage: 220/230/240V AC
- Battery Type: 12V/4.5Ah to 12V/9Ah
- Number of Outlets: 4 to 6
- Efficiency: Up to 90%
- Dimensions: Vary based on model
- Weight: Vary based on model
Product Usage Instructions
UPS Power On
When the UPS is powered on, it will enter a mode for 4
seconds.
AC Mode
When in AC mode, the UPS will provide Automatic Voltage
Regulation (AVR). The LCD will display information in the following
order when touched: 1. Output voltage 2. Input voltage 3. Load
level 4. Battery capacity.
Overload in AC Mode
When an overload occurs in AC mode, an icon will flash, and an
alarm will beep every 0.5 second.
Battery Mode
When in battery mode, the UPS will switch to battery power. When
the battery level is low, an icon will flash. An alarm will beep
every 10 seconds, and the LCD will display information in the
following order when touched: 1. Output voltage 2. Input voltage 3.
Load level 4. Battery capacity.
Overload in Battery Mode
If an overload occurs in battery mode, an icon will flash, and
an alarm will beep every 0.5 second.
FAQs
Q: What are the different models available?
A: The available models are iFP400, iFP650, iFP800, iFP1000,
iFP1500, and iFP2000.
Q: What are the key features of the product?
A: The key features include Automatic Voltage Regulation (AVR),
LCD display, multiple outlets, and battery backup.
Q: How do I know when the UPS is overloaded?
A: An overload is indicated by a flashing icon and audible
alarms at specified intervals.
“`
RU
FSP Manual Guide
– iFP 400VA~2KVA
·
:
&
·
,
. ,
.
·
.
.
6
.
·
.
·
: , ,
.
·
:
.
.
/
·
,
,
. ,
,
.
UPS
LCD
mode
Description
UPS Power on
When UPS is powered on, it will enter this mode for 4 seconds.
AC Mode
AVR , .
LCD information will be displayed in the following order when LCD is touched. 1.Output voltage 2.Input voltage 3.Load level 4.Battery capacity
Overload in AC mode
icon will flash.
When overload occurs, alarm will beep every 0.5 second.
Battery Mode
Overload in battery mode
When battery level is low, icon will flash.
icon will flash.
Alarm will beep every 10 seconds and LCD information will be displayed in the following order when LCD is touched. 1.Output voltage 2.Input voltage 3.Load level 4.Battery capacity
When overload occurs, alarm will beep every 0.5 second.
: .
:
.
.
400-800VA
.
1000VA
.
. .
1500-2000VA
.
A: B: C: / D: USB- () E: ()
–
RU
FSP Manual Guide
iFP 400VA~2KVA
·
,
.
. ,
.
.
·
«»
.
·
, ,
.
·
,
3.5 .
·
,
,
.
·
“OFF”
.
·
.
·
.
·
(
,
).
.
·
.
·
.
·
, ,
, .
·
,
.
·
.
·
.
:
1) ,
.
2) .
3) .
4)
.
5)
.
·
12
. , -, 6-
.
·
, –
– .
·
.
. .
·
,
.
.
·
!!! .
,
–
.
.
·
,
.
·
.
.
.
.
. .
.
6 . .
.
6 . . , . .
400VA/650VA/800VA
iFP400
iFP 650
iFP 800
400VA/
650VA/
800VA/
240W
360W
480W
220/230/240 AC
140-290 AC
± 10%( )
2-6
12V/4.5Ah
12V/7
12V/9
–
1
1
1
4 90%
()
300 x 101 x 142
()
3.55
4.25
4.9
0-90% RH @ 0-40°C ( )
40
*
.
1000VA/1500VA/2000VA
iFP 1000
iFP 1500
iFP 2000
1000VA/
1500VA/
2000VA/
600W
900W
1200W
220/230/240 AC
140-290 AC
± 10%( )
2-6
12V/7
12V/9
12V/9
–
2
2
2
4-6 90%
()
320 x 130 x 182
()
8.2
10.4
11
0-90% RH @ 0-40°C ( )
40
*
UA
FSP Manual Guide
– iFP 400VA~2KVA
–
·
:
&
·
, .
,
.
·
‘ .
.
6
..
·
.
·
: , ,
.
·
:
.
.
/
·
,
,
. ,
,
.
_
–
UPS Power on
, 4 .
AC Mode
AVR ,
.
– , -. 1. 2. 3. 4.
Overload in AC mode
Battery Mode
Overload in battery mode
, .
.
, 0,5 .
10 , – , -. 1.
2. 3. 4. , 0,5 .
: –
.
400-800VA
:
–
.
.
.
1000VA
.
.
A: B: C: /
D: USB- () E: ()
1500-2000VA
.
– .
–
UA
FSP Manual Guide
iFP 400VA~2KVA
·
,
. .
,
.
.
, «»
.
·
, ,
.
·
,
3.5 .
·
–
,
,
.
·
–
“OFF”
.
·
.
·
.
·
( ,
).
.
·
.
·
.
·
,
, , .
·
,
.
·
.
.
:
3) ,
.
4) .
5) .
6)
.
7)
.
·
12
. , -, 6- .
·
, –
– .
·
. .
.
·
,
.
.
!!! .
‘ ,
.
.
·
,
.
·
.
.
.
. .
.
6 . .
.
6 . . ‘ , . .
400VA/650VA/800VA
iFP400
iFP 650
400VA/
650VA/
240W
360W
220/230/240 AC
140-290 AC
iFP 800
800VA/ 480W
± 10%( )
2-6
12V/4.5Ah
12V/7Ah
12V/9Ah
1
1
1
4 90%
()
300 x 101 x 142
()
3.55
4.25
4.9
0-90% RH @ 0-40°C ( )
40
* .
1000VA/1500VA/2000VA
iFP 1000
1000VA/
600W
iFP 1500 1500VA/
900W 220/230/240 AC
140-290 AC
iFP 2000
2000VA/ 1200W
± 10%( )
2-6
12V/7 Ah
12V/9 Ah
12V/9 Ah
2
2
2
4-6 90%
()
320 x 130 x 182
()
8.2
10.4
11
0-90% RH @ 0-40°C ( )
40
* .
User Manual
Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA
INSTALLATION & OPERATION
Inspection
Plug in Equipment
The following items are inside the box: UPS unit User manual
Remove the UPS from its package and inspect it for damage that may have occurred during shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
Plug your equipment to Battery Backup Outlets on the rear panel of
the UPS. NOTE: Make sure that the UPS is powered on to protect all important devices from data loss during power failure. CAUTION: NEVER connect a laser printer or scanner to the battery backup outlets of UPS. The equipment may draw
Connect to Utility Power
significantly power to overload the UPS.
Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best result, charge the battery for 6 hours prior to initial use.
Connect Com. Port and Install Software
(only for the model with USB port) Connect one end of the USB cable to PC and the other to the USB
Connect Modem/Phone Line
(only for the model with RJ-11 port) This UPS protects a single line (1 in/1 out) phone, modem, or fax machine from surges when connected through the UPS. Plug in
port at the rear of the UPS. Download the latest version of ViewPower software from http://www.power-software-download.com to your hard drive. Follow on-screen instructions to complete the software installation.
conning Internet line into the “IN” socket. Use one more Internet line cable in the “OUT” socket and plug one other end to the modem input socket.
REAR PANEL
LCD DISPLAY
Operation Display
UPS Mode
LCD
UPS
Description When UPS is powered
400VA/650VA/800VA
Power on
on, it will enter this mode for 4 seconds.
AC Mode
LCD information will be
displayed in the following
order when LCD is
touched.
1. Output voltage
When AVR is
2. Input voltage
functioning, icon will 3. Load level
flash every second.
4. Battery capacity
Overload
When overload occurs,
in AC
alarm will beep every 0.5
mode
icon will flash.
second.
Battery
Alarm will beep every 10
1000VA
Mode
seconds and LCD information will be
displayed in the following
order when LCD is
When battery level is low, icon will flash.
touched. 1. Output voltage 2. Input voltage
3. Load level
4. Battery capacity
1500VA/2000VA
Overload in battery
When overload occurs, alarm will beep every 0.5
mode
icon will flash.
second.
NOTE: If backlight shuts off, you may activate it by touching the
screen.
Fault Code Table:
Fault condition
LCD
Solutions
Output short
Disconnect short-circuited loads
A. Battery backup outlets: B. AC input
circuited Overload fault
and restart the UPS again.
Disconnect all output loads and restart the UPS again.
C. Fuse/Circuit breaker (option)
Overcharge
Call for service immediately.
D. USB com. port (option) E. Modem/Phone line surge protection (option) F. Cooling fan (only for 1500/2000 models)
Bad or severely
Please replace the battery.
discharged battery
High output voltage
Call for service immediately.
fault
Over-temperature
1. Turn off the unit and wait for
cooling.
2. Or remove excessive loads
and wait for cooling.
If fault alarm occurs, please call for service immediately.
User Manual
Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA
SAFETY CAUTION
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS. Do not dispose of batteries in a fire as they may explode.
SPECIFICATIONS
MODEL
CAPACITY Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time
400
650
800
400VA/240W 650VA/360W 800VA/480W 220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms
A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or
disconnecting batteries terminal.
6) Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.
TROUBLESHOOTING
Waveform
Simulated Sine Wave
Battery Type & No Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level
12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1
6 hours recover to 90% capacity
300 x 101 x 142 mm
3.7
4.4
5
0-90% RH @ 0-40°C non-condensing)
Less than 40dB
Problem
Nothing is displayed on LCD panel.
Possible Cause
Solutions
The UPS is not on. Press the power switch
again to turn on the UPS.
Battery voltage is too Charge the battery at least
low.
6 hours.
Battery fault.
Replace the battery.
MODEL CAPACITY
1000
1500
2000
1KVA/600W 1.5KVA/900W 2KVA/1200W
The UPS
Power cord loose.
always on
battery mode.
Re-plug the power cord.
Input Voltage
Input Voltage Range Output Voltage Regulation Transfer Time
Waveform
220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms Simulated Sine Wave
The UPS continuously beeps.
Backup time too short.
Please check the fault Please check the fault code code for the details. for the details.
Battery voltage is too Charge the battery at least
low.
6 hours.
Battery Type & No
12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2
Overload.
Remove some unnecessary
Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level
6 hours recover to 90% capacity
320 x 130 x 182
8.2
10.4
11
0-90% RH @ 0-40°C non-condensing)
Less than 40dB
*Specifications are subject to change without notice.
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
Battery defect.
Replace the battery.
If any abnormal situations occur that are not listed above, please call for service immediately.
User Manual
Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA
INSTALLATION & OPERATION
:
UPS
UPS : UPS
UPS : UPS
UPS 6
/
UPS
( USB ) USB PC UPS USB http://www.power-software-download.com
ViewPower
( RJ-11 port ) UPS UPS 1 1
LCD DISPLAY
Internet ” IN”
” OUT” Internet
UPS UPS
LCD
UPS
4
REAR PANEL
400VA/650VA/800VA
AC
AC
When AVR is
functioning, icon will flash every second.
LCD LCD 1. 2. 3. 4.
0.5
1000VA
icon will flash.
When battery level is low, icon will flash.
10 LCD
1. 2. 3. 4. 0.5
1500VA/2000VA
icon will flash.
: .
:
LCD
UPS
UPS
A.:
B.
C./ ()
D.USB ()
E./ () F. ( 1500/2000 )
1.
2.
User Manual
Line Interactive UPS
4 0 0 VA – 2 0 0 0 VA
SAFETY CAUTION
– UPS
UPS
UPS UPS UPS
3.5mA
“”
UPS UPS
UPS UPS UPS
UPS
SPECIFICATIONS
MODEL
CAPACITY Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time Waveform Battery Type & No Charging Time Dimension (DxWxH) Net Weight (kgs) Humidity Noise Level
400
650
800
400VA/240W 650VA/360W 800VA/480W 220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms
Simulated Sine Wave
12V/4.5Ahx1 12V/7Ahx1 12V/9Ahx1
6 hours recover to 90% capacity
300 x 101 x 142 mm
3.7
4.4
5
0-90% RH @ 0-40°C non-condensing)
Less than 40dB
MODEL
1000
1500
2000
CAPACITY
Input Voltage Input Voltage Range Output Voltage Regulation Transfer Time
Waveform
Battery Type & No
1KVA/600W 1.5KVA/900W 2KVA/1200W 220/230/240 VAC 162-290 VAC
± 10 % (Bat. mode)
Typical 2-6 ms Simulated Sine Wave 12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2
Charging Time Dimension (DxWxH)
6 hours recover to 90% capacity 320 x 130 x 182
Net Weight (kgs)
8.2
10.4
11
Humidity Noise Level
0-90% RH @ 0-40°C non-condensing) Less than 40dB
*
1) 2 3 4 5 6
12VDC 6
UPS UPS UPS UPS : C2 UPS
TROUBLESHOOTING
LCD UPS
UPS
6
UPS .
UPS
6
UPS
Documents / Resources
![]() |
FSP iFP Series 400VA-2000VA Line Interactive UPS [pdf] User Manual iFP Series, iFP Series 400VA-2000VA Line Interactive UPS, 400VA-2000VA Line Interactive UPS, Line Interactive UPS, Interactive UPS |