Specifications:

  • Module Name: endiio Gateway V2
  • UPN (Unique Product Nr.): ENWM2
  • Used Wireless Module: endiio Wireless Module
    v2
  • PMN (Product Marketing Nr.): endiio WM
  • HVIN (Hardware Version Id Nr.): V2.21
  • Input Voltage: 5 V DC
  • Operating Temperature: N/A
  • No. of Wireless Channels: 4 (915.4, 915.6,
    915.8, 916.0 MHz)
  • Sampling Rate: 15 min.
  • Polling Rate: 30 sec.
  • Dimensions (W x H x D): 37.5 x 91.5 x 103.5
    mm

Product Usage Instructions:

1. Installation

Place the endiio Gateway V2 in an area with good wireless signal
reception.

2. Power Connection

Connect the endiio Gateway V2 to a power source using the
provided 5V DC input.

3. Wireless Setup

Ensure the Gateway is within the specified wireless frequency
bands for optimal performance.

4. Data Forwarding

Configure the Gateway to forward sensor data to a local server
or cloud platform as needed.

5. Maintenance

Regularly check the Gateway for any physical damage and ensure
proper functioning.

Frequently Asked Questions (FAQ):

Q: What is the wireless modulation used by the endiio Wireless
Module v2?

A: The wireless modulation used is GFSK.

Q: What is the separation distance required between the device
and the human body?

A: The recommended separation distance is greater than 20
cm.

“`

endiio Gateway V2 User Manual
Prepared By: Omar Gorgies

endiio GmbH Freiburg, 22.07.2025
22.07.2025

v1.0
1

Revision History

Revision Date

Description

v1.0

22.07.2025 Initial Release

Table of Contents
1 Introduction……………………………………………………………………………………………………………………. 3 2 Product Marketing Information ………………………………………………………………………………………… 3 3 Electrical & Mechanical Specification…………………………………………………………………………………. 4 4 Product Photo…………………………………………………………………………………………………………………. 5 5 Interfaces……………………………………………………………………………………………………………………….. 5 6 Certifications and Compatibilities ……………………………………………………………………………………… 6
6.1 CE RED (Europe) ………………………………………………………………………………………………………. 6 6.2 FCC Part 15 (USA) and ISED RSS (Canada) ……………………………………………………………………. 6 6.3 RF Exposure Information …………………………………………………………………………………………… 6
List of Figures
Figure 1: Modified Antenna at endiio ……………………………………………………………………………………….. 4 Figure 2: endiio Gateway V2 ……………………………………………………………………………………………………. 5
List of Tables
Table 1 Product Marketing Information…………………………………………………………………………………….. 3 Table 2 Wireless Module Specifications…………………………………………………………………………………….. 3 Table 3 Product Electrical and Mechanical Specification……………………………………………………………… 4

22.07.2025

2

1 Introduction
The endiio Gateway is a Sub-GHz (915MHz) wireless device uses the endiio Wireless Module v2.
Its functionality is receiving the wireless sensor values from the Retrofit-Box(s), calculates special vibration parameters (like Indicator, ISO, envelope analysis, etc.), and forwards them to the local server or the cloud.
The Gateway itself is based on the Up-Board from Aaeon.

2 Product Marketing Information
The endiio Gateway v2 device contains the radio module “endiio Wireless Module v2”.

Error! Reference source not found. below lists the endiio Gateway V2 marketing information:

Table 1 Product Marketing Information

Module Name

endiio Gateway V2

UPN (Unique Product Nr.)

ENWM2

Used Wireless Module

endiio Wireless Module v2

PMN (Product Marketing Nr.)

endiio WM

HVIN (Hardware Version Id Nr.)

V2.21

HMN (Host Marketing Name)

endiio Gateway V2

The used radio module “endiio Wireless Module V2” specifications are listed in Table 2.

Table 2 Wireless Module Specifications
FCC ID

2BL4CEN-WM2

IC Number

33310-ENWM2

Wireless Frequency Band

Sub-GHz (902 ­ 928 MHz)

Maximum Output Transmission Power

Typ. 8 dBm

Antenna

MikroTik 868 Omni antenna

Antenna Cable Length

1.5 m

Wireless Modulation

GFSK

Wireless Protocol

IEEE 802.15.4

Separation distance between the device and the human body

> 20 cm

22.07.2025

3

3 Electrical & Mechanical Specification
Table 3 Product Electrical and Mechanical Specification

Input Voltage

5 V DC

Operating Temperature

-20 ­ 60 °C

No. of Wireless Channels

4 (915.4, 915.6, 915.8, 916.0 MHz)

Sampling Rate

15 min.

Polling Rate

30 sec.

Dimensions (W x H x D)

37.5 x 91.5 x 103.5 mm

Note: The Omni-Antenna is realized with SMA connector by manufacturing. A SMA-RPSMA adapter is mounted and glued to the antenna using epoxy compound at our factory prior to shipment, see the figures below. Thus, the antenna would be shipped with a unique connector.

Figure 1: Modified Antenna at endiio

22.07.2025

4

4 Product Photo
Figure 2: endiio Gateway V2
5 Interfaces
The following interfaces are available on the endiio Gateway V2: – Wireless Sub-GHz (915 MHz) RP-SMA Antenna connection – 5 V DC, 4 A Supply – RJ45 Ethernet – 4 x USB-A – HDMI – USB 3.0 OTG

22.07.2025

5

6 Certifications and Compatibilities
6.1 CE RED (Europe)
The device is RED (Radio Equipment Directive) certified for the Sub-GHz. Frequency band (868 MHz).
6.2 FCC Part 15 (USA) and ISED RSS (Canada)
This device is using a wireless module contains licence-exempt transmitter/receiver that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) and complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage. 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
6.3 RF Exposure Information
This equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Ce transmetteur ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne.

22.07.2025

6

Note: Changes or modifications made to this equipment not expressly approved by endiio Engineering GmbH may void the FCC authorization to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

22.07.2025

7

Documents / Resources

endiio V2 Gateway [pdf] User Manual
2BL4CEN-WM2, 2BL4CENWM2, V2 Gateway, V2, Gateway

References

Leave a comment

Your email address will not be published. Required fields are marked *