Vigor2866 G.Fast DSL and Ethernet Router
“
Product Specifications
- Product Name: G.Fast Security Firewall
- Model Number: Vigor2866
- Manufacturer: DrayTek Corp.
- Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park,
Hsinchu 303, Taiwan - Firmware Version: 4.4.6.2
Product Usage Instructions
1. Safety Instructions
Before setting up the router, read the installation guide
thoroughly. The router is a complex electronic unit that should
only be repaired by professionals.
2. Installation Guide
Follow these steps to set up the Vigor2866 G.Fast Security
Firewall:
- Connect the router to a power source using the provided
adapter. - Connect your computer to the router using an Ethernet
cable. - Access the router’s configuration page through a web browser by
entering the default IP address (usually 192.168.1.1). - Follow the on-screen instructions to configure your network
settings, including SSID, password, and security protocols. - Save your settings and restart the router if required.
Frequently Asked Questions (FAQ)
Q: Where can I find firmware updates for the Vigor2866 G.Fast
Security Firewall?
A: For future firmware updates, please visit the DrayTek website
at https://fw.draytek.com.tw/Vigor2866/
Q: How can I contact customer support for technical
assistance?
A: For technical support and assistance, please contact the
local representative or reach out to DrayTek Corporation
directly.
“`
Vigor2866 G.Fast Security Firewall
Quick Start Guide (for Wired Model)
Version: 1.5 Firmware Version: 4.4.6.2 (For future update, please visit DrayTek web site)
Date: May 9, 2025 i
Intellectual Property Rights (IPR) Information
Copyrights Trademarks
© All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders. The following trademarks are used in this document: Microsoft is a registered trademark of Microsoft Corp. Windows, Windows 8, 10, 11 and Explorer are trademarks of Microsoft
Corp. Apple and Mac OS are registered trademarks of Apple Inc. Other products may be trademarks or registered trademarks of their
respective manufacturers.
Safety Instructions and Approval
Safety Instructions
Warranty
Read the installation guide thoroughly before you set up the router. The router is a complicated electronic unit that may be repaired only be
authorized and qualified personnel. Do not try to open or repair the router yourself. Do not place the router in a damp or humid place, e.g. a bathroom. Do not stack the routers. The router should be used in a sheltered area, within a temperature range of +5 to +40 Celsius. Do not expose the router to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources. Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards. Do not power off the router when saving configurations or firmware upgrades. It may damage the data in a flash. Please disconnect the Internet connection on the router before powering it off when a TR-069/ ACS server manages the router. Keep the package out of reach of children. When you want to dispose of the router, please follow local regulations on conservation of the environment. We warrant to the original end user (purchaser) that the router will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore-store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes.
ii
EU Declaration of Conformity Hereby, DrayTek Corporation declares that the equipment type Vigor2866 is in compliance with EU EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: https://fw.draytek.com.tw/Vigor2866/Document/CE/ Product name: G.Fast Security Firewall
Model number: Vigor2866
Manufacturer: DrayTek Corp.
Address:
No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan
Declaration of Conformity
Hereby, DrayTek Corporation declares that the equipment type Vigor2866 is in compliance with The
Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety)
Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032).
The full text of the UKCA Declaration of Conformity is available at the following internet address:
https://fw.draytek.com.tw/Vigor2866/Document/CE/
Product name: G.Fast Security Firewall
Model number: Vigor2866
Manufacturer: DrayTek Corp.
Address:
No.26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan
Regulatory Information
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device may accept any interference received, including interference that may cause undesired operation.
iii
USA Local Representative
Company name Address ZIP Code Contact Person
ABP International Inc.
13988 Diplomat Drive Suite 180 Dallas TX 75234
75234
E-mail henry@abptech.com
Mr. Henry N Castillo
Tel.
(972)831-1600 140
Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
External Power Supply ErP Information
1
2
3
4
5
6
7
8
9
10
11
12
A
Manufact
urer
CWT
CWT
CWT
CWT
CWT
APD
APD
APD
APD
MOSO
MOSO
MOSO
B
Sangtai
Sangtai
Sangtai
Industrial
Industrial
Industrial
Park,
Park,
Park,
No. 222,
No. 222,
No. 222,
No. 222,
No. 222,
Guanwai
Guanwai
Guanwai
Address
Sec. 2, Nankan
Rd., Lujhu Township, Taoyuan County 338,
Sec. 2, Nankan
Rd., Lujhu Township, Taoyuan County 338,
Sec. 2, Nankan
Rd., Lujhu Township, Taoyuan County 338,
Sec. 2, Nankan
Rd., Lujhu Township, Taoyuan County 338,
Sec. 2, Nankan
Rd., Lujhu Township, Taoyuan County 338,
No.5, Lane 83, Lung-Sou
St., Taoyuan City 330, Taiwan
No.5, Lane 83, Lung-Sou
St., Taoyuan City 330, Taiwan
No.5, Lane 83, Lung-Sou
St., Taoyuan City 330, Taiwan
No.5, Lane 83, Lung-Sou
St., Taoyuan City 330, Taiwan
Xiaobaim ang
Songbai Road, Nanshan District, 518108 Shenzhen
Xiaobaim ang
Songbai Road, Nanshan District, 518108 Shenzhen
Xiaobaim ang
Songbai Road, Nanshan District, 518108 Shenzhen
Taiwan
Taiwan
Taiwan
Taiwan
Taiwan
,
,
,
Guangdon Guangdon Guangdon
g,
g,
g,
China
China
China
C
MS-
MSS-
V30-V300
2ABB012F
2ABB018F
2ABL024F
2ABL030F 2ABN036F
WA-12M1
WB-18D12 WA-24Q12 WA-36A12 V2000R12
V2500WR
0R12
UK
UK
UK
UK
UK
2FG
FG
FG
FG
0-
120-
0-036T0-
Model
024Q0-GB 030E0-GB
GB
identifier
MS-
MSS-
V30-V300
2ABB012F
2ABB018F
2ABL024F
2ABL030F 2ABN036F
WA-12M1
WB-18D12 WA-24Q12 WA-36A12 V2000R12
V2500WR
0R12
EU
EU
EU
EU
EU
2FK
FK
FK
FK
0-
120-
0-036T0-D
024Q0-DE
030E0-DE
E
D
Input voltage
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
100~240V
E
Input AC
frequenc
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
y
Output
voltage
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
12.0V
DC
F
Output
current
1.0A
1.5A
2.0A
2.5A
3.0A
1.0A
1.5A
2.0A
3.0A
2.0A
2.5A
3.0A
G
Output
power
12.0W
18.0W
24.0W
30.0W
36.0W
12.0W
18.0W
24.0W
36.0W
24.0W
30.0W
36.0W
H
Average
active
84.9%
86.2%
87.6%
87.8%
89.8%
83.7%
85.4%
88.6%
88.2%
87.8%
89.5%
89.3%
efficiency
I
Efficiency
at low
73.6%
78.0%
81.3%
83.3%
83.7%
74.5%
80.5%
86.4%
85.4%
85.4%
84.7%
87.7%
load 10%
J
No-load
power consumpt
0.07W
0.07W
0.07W
0.07W
0.07W
0.07W
0.10W
0.07W
0.10W
0.10W
0.08W
0.10W
ion
External power supply (Power Adapter) information. For more update, please visit www.draytek.com.
iv
Table of Contents
1. Package Content …………………………………………………………………………………….. 1 2. Panel Explanation……………………………………………………………………………………. 2 3. Hardware Installation ………………………………………………………………………………. 4
3.1 Network Connection ……………………………………………………………………………………………………. 4 3.2 Wall-Mounted Installation …………………………………………………………………………………………….. 5
4. Software Configuration ……………………………………………………………………………. 6
4.1 Quick Start Wizard for Network Connection……………………………………………………………………. 6
5. Customer Service ………………………………………………………………………………….. 12
Be a Registered Owner …………………………………………………………………………………………………… 12 Firmware & Tools Updates ………………………………………………………………………………………………. 12
v
1. Package Content
Take a look at the package content. If there is anything missed or damaged, please contact DrayTek or dealer immediately.
Vigor Router
Quick Start Guide
RJ-45 Cable (Ethernet)
RJ-11 to RJ-11 Cable or RJ-11 to RJ-45 Cable
The type of the power adapter depends on the country that the router will be installed. * The maximum power consumption is 22 Watt.
UK-type Power Adapter
EU-type Power Adapter
USA/Taiwan-type Power Adapter
AU/NZ-type Power Adapter
1
2. Panel Explanation
LED ACT WAN2 QoS USB1~2
DSL
WCF
VPN
DMZ WAN2 / P6 Left LED Right LED LAN P1-P5 Left LED
Status Off Blinking On Off Blinking On Off On Off Blinking
On
Blinking
On
Off On Off Blinking On Off Blinking
On Off Blinking On Off
On Off Blinking
Explanation The router is powered off. The router is powered on and running normally. Internet connection is ready. Internet connection is not ready. The data is transmitting. The QoS function is active. The QoS function is inactive. USB device is connected and ready for use. No USB device is connected. The data is transmitting. The router is ready to access Internet through DSL link. Slowly: The DSL connection is ready. Quickly: The connection is training. The Web Content Filter is active. (It is enabled from Firewall >> General Setup). WCF is disabled.
The VPN tunnel is active. VPN services are disabled Traffic is passing through VPN tunnel. The DMZ function is enabled. The DMZ function is disabled. The data is transmitting.
The port is connected. The port is disconnected. The data is transmitting. The port is connected with 1000Mbps. The port is connected with 10/100Mbps.
The port is connected. The port is disconnected. The data is transmitting.
2
Right LED
On Off
The port is connected with 1000Mbps. The port is connected with 10/100Mbps
Interface Factory Reset
USB1~2
WAN2 / P6
LAN P1-P5 DSL PWR ON/OFF
Description Restore the default settings. Usage: Turn on the router (ACT LED is blinking). Press the hole and keep for more than 5 seconds. When you see the ACT LED begins to blink rapidly than usual, release the button. Then the router will restart with the factory default configuration. Connecter for a USB device (for 3G/4G USB Modem or printer or thermometer). Connecter for local network devices or modem for accessing Internet. It is a switchable port. It can be used for LAN connection or WAN connection according to the settings configured in WUI. Connecters for local network devices. Connecter for accessing the Internet.
Connecter for a power adapter.
Power Switch.
3
3. Hardware Installation
This section will guide you to install the router through hardware connection and configure the router’s settings through web browser. Before starting to configure the router, you have to connect your devices correctly.
3.1 Network Connection
1. Connect the DSL interface to the land line jack with a DSL line cable, or Connect the cable Modem/DSL Modem/Media Converter to the WAN port of router with Ethernet cable (RJ-45).
2. Connect one end of an Ethernet cable (RJ-45) to one of the LAN ports of the router and the other end of the cable (RJ-45) into the Ethernet port on your computer.
3. Connect one end of the power adapter to the router’s power port on the rear panel, and the other side into a wall outlet.
4. Power on the device by pressing down the power switch on the rear panel. 5. The system starts to initiate. After completing the system test, the ACT LED
will light up and start blinking. (For the detailed information of LED status, please refer to section 2. Panel Explanation)
4
3.2 Wall-Mounted Installation
Vigor router has keyhole type mounting slots on the underside. 1. Drill two holes on the wall. The distance between the holes shall be 168mm. 2. Fit screws into the wall using the appropriate type of wall plug.
Note
The recommended drill diameter shall be 6.5mm (1/4″).
3. When you finished about procedure, the router has been mounted on the wall firmly.
5
4. Software Configuration
To access Internet, please finish basic configuration after completing the hardware installation.
4.1 Quick Start Wizard for Network Connection
The Quick Start Wizard is designed for you to easily set up your router for Internet access. You can directly access the Quick Start Wizard via Web User Interface. Make sure your PC connects to the router correctly.
Note
You may either simply set up your computer to get IP dynamically from the router or set up the IP address of the computer to be the same subnet as the default IP address of Vigor router 192.168.1.1. For the detailed information, please refer to Trouble Shooting of the user’s guide.
1. Open a web browser on your PC and type http://192.168.1.1. A pop-up window will open to ask for username and password.
2. Please enter “admin/admin” as the Username/Password and click Login.
6
3. Next, the following page will appear. You must change the login password before accessing the web user interface. Please set a password with the highest level of strength for network security.
Note
If you fail to access to the web configuration, please go to “Trouble Shooting” on User’s Guide for detecting and solving your problem.
4. Now, the Main Screen will pop up. Click Wizards>>Quick Start Wizard.
Note
The home page will change slightly in accordance with the router you have.
7
5. The first screen of Quick Start Wizard is entering login password. Since you have set a new password by Step 3, click Next directly.
6. On the next page as shown below, please select the WAN interface that you use. If DSL interface is used, please choose WAN1; if Ethernet interface is used, please choose WAN2; if 3G USB modem is used, please choose WAN5 or WAN6. Then click Next for next step. WAN1, WAN2, WAN5 and WAN6 will bring up different configuration page. Here, we take WAN1 as an example.
7. Click Next to go to the following page. You have to select the appropriate Internet access type according to the information from your ISP. For example, you should select PPPoA mode if the ISP provides you PPPoA interface. In addition, the field of For ADSL Only will be available only when ADSL is detected. Then click Next for next step.
8
PPPoE/PPPoA 1. Choose WAN1 as WAN Interface and click the Next button; you will get the
following page.
9
2. After finished the above settings, simply click Next.
3. Please manually enter the Username/Password provided by your ISP. Then click Next for viewing summary of such connection.
4. Click Finish. A page of Quick Start Wizard Setup OK!!! will appear. Then, the system status of this protocol will be shown.
5. Now, you can enjoy surfing on the Internet.
10
MPoA / Static or Dynamic IP 1. Choose WAN1 as WAN Interface and click the Next button; you will get the
following page.
2. Please type in the IP address/mask/gateway information originally provided by your ISP. Then click Next for viewing summary of such connection.
3. Click Finish. A page of Quick Start Wizard Setup OK!!! will appear. Then, the system status of this protocol will be shown.
4. Now, you can enjoy surfing on the Internet.
11
5. Customer Service
If the router cannot work correctly after trying many efforts, please contact your dealer for further help right away. For any questions, please feel free to send e-mail to support@draytek.com.
Be a Registered Owner
Web registration is preferred. You can register your Vigor router via https://myvigor.draytek.com.
Firmware & Tools Updates
Due to the continuous evolution of DrayTek technology, all routers will be regularly upgraded. Please consult the DrayTek web site for more information on newest firmware, tools and documents. https://www.draytek.com
ALVACO Telecomunicaciones Espana, S.L Avenida de Italia 10 Centro de Transportes de Coslada 28821 Coslada, Madrid, Spain AntiPode 12 Rue des Chauffours 95000 Cergy France BRINET sp. z o.o. sp.k. ul. Lubowska 23, 60-433 Pozna CMS UK – CMS Distribution Limited, 15 Worship Street, London, EC2A 2DT Ireland – CMS Distribution Limited, Bohola Road, Kiltimagh, Co Mayo, Ireland
Comdate Access AB Industrivagen 44, 941 47 Pitea Sweden IKI d.o.o. ZAGREB IKI d.o.o, Rapska 42, 10000 Zagreb, Croatia LEXIS S.A. 2-4, Karpathou str. & Ethnikis Antistaseos, 15344, Gerakas, Athens-Greece Network Elements Kft. 1095 Budapest Mester 37-39, B lh. alagsor 4., Hungary NoWire Nordic AB Box 8167,163 08 Spanga, Sweden OptiVisus Lda. Rua Capitão Ramires nº17A 1000-084 Lisboa, Portugal
ScanAccess A/S Kirkeltevej 138, 3450 Allerod, DK, DENMARK Spider Electronics sas Via Enrico Fermi 11-10040, Caselette (TO) Italy. Telos d.o.o. Parmova 14, 1000 Ljubljana, Slovenia UniVorx GmBH Zeppelinstrasse 3, 12529, Schoenefeld, Germany Xpert Data b.v. Oosterveldsingel 2 7558 PK Hengelo (Ov)
12
Documents / Resources
![]() |
Draytek Vigor2866 G.Fast DSL and Ethernet Router [pdf] User Guide Vigor2866, Vigor2866 G.Fast DSL and Ethernet Router, G.Fast DSL and Ethernet Router, DSL and Ethernet Router, Ethernet Router |