DIGITAL MONITORING PRODUCTS XT30INT Control Panel Installation Guide

XT30INT Control Panel

Product Information

Specifications

  • Model: XT30INT Control Panel
  • Manufacturer: Digital Monitoring Products, Inc.
  • Power Supply: 16 VAC 43 VA
  • Secondary Power Supply: 12 VDC rechargeable batteries, 1.0 Amps
    maximum charging current
  • Operating Voltage Range: 8.8 VDC – 14.2 VDC
  • Minimum Voltage for Auxiliary Output: 10.2 VDC

Product Usage Instructions

Before You Begin

The XT30INT Control Panel compliance guide provides detailed
information on the functions and options of the panel. Before
installation or operation, it is recommended to read through the
guide thoroughly to understand the operation, functionality, and
programming options.

Wiring Diagram

Follow the wiring diagram provided for proper installation of
the XT30INT Control Panel. Ensure proper support for power cord
using Strain Relief/Cable Clamp. Wiring on terminals 5 through 26
must exit right and maintain a 7 mm separation from the AC and
battery positive wiring.

Operation

The XT30INT Control Panel is designed to be used with intrusion
and hold-up systems compliant with EN 50131-1 security grade
standards. Ensure proper environmental conditions such as operating
temperature and humidity range are maintained for optimal
performance.

Security Grade

The panel complies with security grade standards outlined in EN
50131-1.

Environmental Class

Maintain the recommended operating temperature and humidity
range for the panel.

Power Supply

Use the specified power supply requirements for the panel and
ensure proper voltage levels are maintained.

International Certifications

The XT30INT Control Panel meets Intertek (ETL) international
certification standards.

Documentation

Refer to the provided compliance guide and documentation for
detailed instructions on installing, operating, and programming the
XT30INT Control Panel.

FAQ

Q: How often should I replace the rechargeable batteries?

A: It is recommended to replace the 12 VDC rechargeable
batteries every 3 to 5 years for optimal performance.

Q: What is the minimum voltage required for Auxiliary Output
sensor trips to be processed?

A: The minimum voltage required for Auxiliary Output sensor
trips to be processed is 10.2 VDC.

INTERNATIONAL COMPLIANCE GUIDE
XT30INT Control Panel
DDIIGGIITTAALL MMOONNIITTOORRIINNGG PPRROODDUUCCTTSS,, IINNCC..

MODEL XT30INT CONTROL PANEL COMPLIANCE GUIDE
Contains compliance instructions for use with the Model XT30INT Control Panel.
© 2024 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable.
This information is subject to change without notice.

CONTENTS
Before You Begin……………………………………1
Wiring Diagram…………………………………….. 2
Operation……………………………………………… 3
Intrusion and Hold-up Systems EN 50131-1 ………………… 3 Security Grade ……………………………………………………………………………..3 Environmental Class…………………………………………………………………….3 Power Supply………………………………………………………………………………..3
Control and Indicating Equipment EN 50131-3 ………….. 3 Operating Temperature and Humidity Range…………………………3 Weights and Dimensions…………………………………………………………….3
XT30INT Status List Display ………………………………………. 3 Entry/Exit Delay……………………………………………………………………………4 Transmit Delay………………………………………………………………………………4 Bell Cutoff ……………………………………………………………………………………..4 Power Fail ……………………………………………………………………………………..4 Auto Arming the System…………………………………………………………….4 Zone Expander……………………………………………………………………………..4 Swinger Bypass…………………………………………………………………………….4 Masking ………………………………………………………………………………………….4 User Codes ……………………………………………………………………………………4 Keypad Display Time Out……………………………………………………………4 Control Panel Tamper ………………………………………………………………….4 Event Recording …………………………………………………………………………..4 Discharge/Recharge ……………………………………………………………………4 Closing Code…………………………………………………………………………………5 Notification Output Signals………………………………………………………..5 Operation Mode……………………………………………………………………………5 Dual Path Operation ……………………………………………………………………5 Control Panel Unavailability ……………………………………………………….5
International Certifications ……………………6
Intertek (ETL) ……………………………………………………………….6
Documentation ……………………………………..6

BEFORE YOU BEGIN
This guide provides compliance information for the DMP XT30INT Control Panel. After this Introduction, the remaining sections describe the functions along with the available options. Before starting, we recommend that you read through the contents of this guide. The information contained here allows you to quickly learn the operation, functionality, and programming options of the panel to meet specific applications.
This guide covers all the requirements for the XT30INT Control Panel

Digital Monitoring Products | XT30INT Compliance Guide

1

WIRING DIAGRAM

DMP Transformers Model 3230INT – Wire-in 16 VAC 43 VA
Use Strain Relief/Cable Clamp to support Power Cord

XT30INT Control Panel

J7 RJ SUPERVISION

J3 PHONE LINE

J1 ETHERNET

J8

Programming Header

RED

Use DMP Model 330 Harness

PROG

Terminals 5-20 are Power Limited

24 header for cellular connection
CELL

J11
1 2 3 4
OUTPUTS

J16 RESET

INPUT

OUTPUT

AC Wiring must be in conduit and exit out the left side of the enclosure.
Wiring on terminals 5 through 26 must exit right and maintain a 7 mm separation from the AC and battery positive wiring.

GROUND

Conduit s
s 16 to 18

1

2

3

4

AC AC B+ B-

gauge wire

5

6

7

8

9

10

11

12

BELL GND RED YEL GRN BLK SMK Z1

13

14

GND Z2

s
MAXIMUM AC WIRE DISTANCE 16 gauge wire: 22 meters 18 gauge wire: 13 meters

Bell Keypad Bus s 1k Ohm EOL

S SS S 1k Ohm 1k Ohm

Smoke

Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8

15

16

17

Z3 GND Z4

S SS S 1k Ohm 1k Ohm

18

19

20

Z5 GND Z6

S SS S 1k Ohm 1k Ohm

21

22

23

Z7 GND Z8

S SS S 1k Ohm 1k Ohm

24

25

26

Z9 Z10+ Z10-

Zone 10

S

S

3.3k Ohm Resistor DMP Model 309

RED BLACK

Earth Ground

SECONDARY POWER SUPPLY 1.0 Amps maximum charging current. Use only 12 VDC rechargeable batteries. Replace every 3 to 5 years.
MAXIMUM OPERATING RANGE 8.8 VDC – 14.2 VDC
Minimum voltage on Auxillary output to process Sensor trips is 10.2 VDC
LISTED RESISTORS 1.0k Ohm – DMP Model 311 3.3k Ohm – DMP Model 309

BELL 10.2 – 13.9VDC Total current: 1.5 Amps max.
AUX (RED) Up to 500 mA auxiliary current at 10.2 VDC – 13.9 VDC from Terminal 7 Up to 325 mA auxiliary current at 10.2 VDC 13.9 VDC from Terminal 7 when using (2) Model 364 1.3 Ah Batteries
SMOKE OUTPUT 100 mA at 10.2 – 13.9 VDC Terminal 11

For a complete description of wiring connections, refer to the XT30 International Installation Guide (LT-0980INT). For complete programming instructions, refer to the XT30 International Programming Guide (LT-098INT).

Digital Monitoring Products | XT30INT Compliance Guide

2

OPERATION
Intrusion and Hold-up Systems EN 50131-1
Security Grade
The XT30INT provides Security Grade 2 fulfilling Options A, B, C, and D.

Environmental Class
The XT30INT provides Environmental Class II.

Power Supply
The XT30INT employs a Type A power supply.
Control and Indicating Equipment EN 50131-3
Operating Temperature and Humidity Range
The XT30INT is suitable for temperatures ranging from 0°C to 49°C and a relative humidity of 80%.

Weights and Dimensions
The XT30INT PCB weighs .55 kg and is 26 cm wide by 10.5 cm high.
XT30INT Status List Display

PRIORITY CATEGORY

DESCRIPTION

LATCHES DISPLAY

1

Fire Zone Alarms

FI and FV Zone Alarms

Y

2

Emergency Alarms

EM Zone Alarms

Y

3

Fire Troubles and Supervisory FI, FV, and EM Troubles

Alarms and Troubles

SV Alarms and Troubles

Y

4

Burglary Zone Alarms

NT, DY, EX, and AR Zone Alarms

N

5

System Messages

Walk Test

Transmitter Missing

Transmitter Low Battery

Wireless Jamming Wireless Keypad Missing, Tamper, AC Power,

N

Low Battery, Wireless Keypad Trouble

Z-Wave Lock Low Battery

Any Other System Monitor Troubles

6

Zone Troubles

Device Missing Device Tamper

7

Late to Close Messages

System Has Not Armed as Scheduled

N

8

Armed or Ready Status

Status of Panel

N

9

Day and Time

Current Date and Time

N

10

Today’s Current Weather

Today’s Weather

N

11

Tomorrow’s Weather

Tomorrow’s Weather

N

Digital Monitoring Products | XT30INT Compliance Guide

3

Entry/Exit Delay
In System Options, set Entry Delay and Exit Delay to 30 to 45 seconds.

Transmit Delay
In Communications, Transmit Delay must be set to 30 seconds.

Bell Cutoff
In Bell Options, Bell Cutoff must be set to 2 to 15 minutes.

Power Fail
In System Options, Power Fail must be set to 1 or less.

Auto Arming the System
In Area Information, Closing Check must be ON when using Auto Arm. When arming, Closing Time! is displayed for 10 minutes and the keypad sounds. Bad zones are processed according to the Bad Zones programming in Area Information. Other troubles are automatically overridden.

Zone Expander
When using a zone expander module, one zone of the module must be used as tamper supervision.

Swinger Bypass
In System Options, SWGRBYPS TRIPS: must be set to 3 or higher.

Masking
Connect a zone to the masking contacts of a device, such as a PIR with masking contacts. Name the zone in Zone Programming X Masking where X is the name of the detector zone. For Alarm Action, set the Transmit Message to T (Trouble) for both Disarmed Open, Disarmed Short, Armed Open, and Armed Short actions.

User Codes
User codes must be at least 4-digits (0 – 9) for a total of 10,000 possible combinations.

Keypad Display Time Out
A valid User Code is required to be entered to display the Status List. The display will time out in 60 seconds with no key presses. A valid User Code will be required to be entered again to view list.

Control Panel Tamper
Wire an enclosure tamper switch to a panel zone and name the zone Panel Tamper in Zone Information. Set the Disarmed message to TRBL.

Event Recording
The Central Station must keep a list of events from the panel for 30 days. Events are stored locally in non-volatile memory. Manufacturer part number AT24C256C.

Discharge/Recharge
The XT30INT battery charging circuit float charges at 13.8 VDC at a maximum current of 1.5 Amps using a 43VA transformer. Listed below are the various battery voltage level conditions:

Battery Trouble: Below 11.9 VDC Battery Trouble: Above 12.6 VDC

The panel disconnects the battery any time the battery voltage drops below 10.2 VDC. This prevents battery deep discharge damage.

Digital Monitoring Products | XT30INT Compliance Guide

4

Closing Code
In System Options, set Closing Code to YES.
Notification Output Signals
Provides Hold-up, Tamper, and Intrusion notifications.
Operation Mode
Stores and forwards all messages to SCS-VR or SCS-1R.
Dual Path Operation
Communication takes place on the primary path with backup paths being used only when the primary path fails or when the backup path is being used to send duplicate messages.
Control Panel Unavailability
The control panel is considered unavailable when the system message 16 PANEL NOT RESPONDING is generated by the central station receiver.

Digital Monitoring Products | XT30INT Compliance Guide

5

INTERNATIONAL CERTIFICATIONS

Intertek (ETL)

EN 50130-4

EMC Product Family Standard: Immunity Requirements for Components of Fire, Intruder and Social Alarm Systems

EN 50130-5

Environmental Standards

EN 50131-1:2006+A1 Intrusion and Hold-up systems

EN 50131-3:2009

Control and Indicating Equipment

EN 50131-6:2008

Power Supplies

EN 50136-1

Alarm Transmission Systems and Equipment

EN 50136-2:2013

Supervised Premises Transceiver

EN 61000-3-2

Limits – Limits for Harmonic Current Emissions (Equip. Input Current up to and Including 16 A per Phase) Includes A1 & A2 July 1, 2009

EN 61000-3-3

Limitation of Voltage Fluctuations & Flicker in LowVoltage Supply Systems for Equip. with Rated Current Less Than or Equal to 16 A per Phase & Not Subject to Conditional Connection

EN 61000-6-4

Generic Standards – Emission Standard for Industrial Environments

DOCUMENTATION

Power Supply Security Grade EN 50131-1 Notification Requirements Environmental Class Operating Temperature Relative Humidity Weight Dimensions

Type A 2
Grade 2 Options A, B, or C II 0°C – 49°C 32°F – 120°F 80% 0.55 kg 26W x 10.5H cm

18205

Designed, engineered, and manufactured in Springfield, MO using U.S. and global components.
LT-1385INT 1.01 216424025
©© 22002244

INTRUSION · FIRE · ACCESS · NETWORKS
2500 North Partnership Boulevard Springfield, Missouri 65803-8877
417.831.9362 | DMP.com