XT30INT Control Panel
Product Information
Specifications
- Model: XT30INT Control Panel
- Manufacturer: Digital Monitoring Products, Inc.
- Power Supply: 16 VAC 43 VA
- Secondary Power Supply: 12 VDC rechargeable batteries, 1.0 Amps
maximum charging current - Operating Voltage Range: 8.8 VDC – 14.2 VDC
- Minimum Voltage for Auxiliary Output: 10.2 VDC
Product Usage Instructions
Before You Begin
The XT30INT Control Panel compliance guide provides detailed
information on the functions and options of the panel. Before
installation or operation, it is recommended to read through the
guide thoroughly to understand the operation, functionality, and
programming options.
Wiring Diagram
Follow the wiring diagram provided for proper installation of
the XT30INT Control Panel. Ensure proper support for power cord
using Strain Relief/Cable Clamp. Wiring on terminals 5 through 26
must exit right and maintain a 7 mm separation from the AC and
battery positive wiring.
Operation
The XT30INT Control Panel is designed to be used with intrusion
and hold-up systems compliant with EN 50131-1 security grade
standards. Ensure proper environmental conditions such as operating
temperature and humidity range are maintained for optimal
performance.
Security Grade
The panel complies with security grade standards outlined in EN
50131-1.
Environmental Class
Maintain the recommended operating temperature and humidity
range for the panel.
Power Supply
Use the specified power supply requirements for the panel and
ensure proper voltage levels are maintained.
International Certifications
The XT30INT Control Panel meets Intertek (ETL) international
certification standards.
Documentation
Refer to the provided compliance guide and documentation for
detailed instructions on installing, operating, and programming the
XT30INT Control Panel.
FAQ
Q: How often should I replace the rechargeable batteries?
A: It is recommended to replace the 12 VDC rechargeable
batteries every 3 to 5 years for optimal performance.
Q: What is the minimum voltage required for Auxiliary Output
sensor trips to be processed?
A: The minimum voltage required for Auxiliary Output sensor
trips to be processed is 10.2 VDC.
INTERNATIONAL COMPLIANCE GUIDE
XT30INT Control Panel
DDIIGGIITTAALL MMOONNIITTOORRIINNGG PPRROODDUUCCTTSS,, IINNCC..
MODEL XT30INT CONTROL PANEL COMPLIANCE GUIDE
Contains compliance instructions for use with the Model XT30INT Control Panel.
© 2024 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable.
This information is subject to change without notice.
CONTENTS
Before You Begin……………………………………1
Wiring Diagram…………………………………….. 2
Operation……………………………………………… 3
Intrusion and Hold-up Systems EN 50131-1 ………………… 3 Security Grade ……………………………………………………………………………..3 Environmental Class…………………………………………………………………….3 Power Supply………………………………………………………………………………..3
Control and Indicating Equipment EN 50131-3 ………….. 3 Operating Temperature and Humidity Range…………………………3 Weights and Dimensions…………………………………………………………….3
XT30INT Status List Display ………………………………………. 3 Entry/Exit Delay……………………………………………………………………………4 Transmit Delay………………………………………………………………………………4 Bell Cutoff ……………………………………………………………………………………..4 Power Fail ……………………………………………………………………………………..4 Auto Arming the System…………………………………………………………….4 Zone Expander……………………………………………………………………………..4 Swinger Bypass…………………………………………………………………………….4 Masking ………………………………………………………………………………………….4 User Codes ……………………………………………………………………………………4 Keypad Display Time Out……………………………………………………………4 Control Panel Tamper ………………………………………………………………….4 Event Recording …………………………………………………………………………..4 Discharge/Recharge ……………………………………………………………………4 Closing Code…………………………………………………………………………………5 Notification Output Signals………………………………………………………..5 Operation Mode……………………………………………………………………………5 Dual Path Operation ……………………………………………………………………5 Control Panel Unavailability ……………………………………………………….5
International Certifications ……………………6
Intertek (ETL) ……………………………………………………………….6
Documentation ……………………………………..6
BEFORE YOU BEGIN
This guide provides compliance information for the DMP XT30INT Control Panel. After this Introduction, the remaining sections describe the functions along with the available options. Before starting, we recommend that you read through the contents of this guide. The information contained here allows you to quickly learn the operation, functionality, and programming options of the panel to meet specific applications.
This guide covers all the requirements for the XT30INT Control Panel
Digital Monitoring Products | XT30INT Compliance Guide
1
WIRING DIAGRAM
DMP Transformers Model 3230INT – Wire-in 16 VAC 43 VA
Use Strain Relief/Cable Clamp to support Power Cord
XT30INT Control Panel
J7 RJ SUPERVISION
J3 PHONE LINE
J1 ETHERNET
J8
Programming Header
RED
Use DMP Model 330 Harness
PROG
Terminals 5-20 are Power Limited
24 header for cellular connection
CELL
J11
1 2 3 4
OUTPUTS
J16 RESET
INPUT
OUTPUT
AC Wiring must be in conduit and exit out the left side of the enclosure.
Wiring on terminals 5 through 26 must exit right and maintain a 7 mm separation from the AC and battery positive wiring.
GROUND
Conduit s
s 16 to 18
1
2
3
4
AC AC B+ B-
gauge wire
5
6
7
8
9
10
11
12
BELL GND RED YEL GRN BLK SMK Z1
13
14
GND Z2
s
MAXIMUM AC WIRE DISTANCE 16 gauge wire: 22 meters 18 gauge wire: 13 meters
Bell Keypad Bus s 1k Ohm EOL
S SS S 1k Ohm 1k Ohm
Smoke
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
15
16
17
Z3 GND Z4
S SS S 1k Ohm 1k Ohm
18
19
20
Z5 GND Z6
S SS S 1k Ohm 1k Ohm
21
22
23
Z7 GND Z8
S SS S 1k Ohm 1k Ohm
24
25
26
Z9 Z10+ Z10-
Zone 10
S
S
3.3k Ohm Resistor DMP Model 309
RED BLACK
Earth Ground
SECONDARY POWER SUPPLY 1.0 Amps maximum charging current. Use only 12 VDC rechargeable batteries. Replace every 3 to 5 years.
MAXIMUM OPERATING RANGE 8.8 VDC – 14.2 VDC
Minimum voltage on Auxillary output to process Sensor trips is 10.2 VDC
LISTED RESISTORS 1.0k Ohm – DMP Model 311 3.3k Ohm – DMP Model 309
BELL 10.2 – 13.9VDC Total current: 1.5 Amps max.
AUX (RED) Up to 500 mA auxiliary current at 10.2 VDC – 13.9 VDC from Terminal 7 Up to 325 mA auxiliary current at 10.2 VDC 13.9 VDC from Terminal 7 when using (2) Model 364 1.3 Ah Batteries
SMOKE OUTPUT 100 mA at 10.2 – 13.9 VDC Terminal 11
For a complete description of wiring connections, refer to the XT30 International Installation Guide (LT-0980INT). For complete programming instructions, refer to the XT30 International Programming Guide (LT-098INT).
Digital Monitoring Products | XT30INT Compliance Guide
2
OPERATION
Intrusion and Hold-up Systems EN 50131-1
Security Grade
The XT30INT provides Security Grade 2 fulfilling Options A, B, C, and D.
Environmental Class
The XT30INT provides Environmental Class II.
Power Supply
The XT30INT employs a Type A power supply.
Control and Indicating Equipment EN 50131-3
Operating Temperature and Humidity Range
The XT30INT is suitable for temperatures ranging from 0°C to 49°C and a relative humidity of 80%.
Weights and Dimensions
The XT30INT PCB weighs .55 kg and is 26 cm wide by 10.5 cm high.
XT30INT Status List Display
PRIORITY CATEGORY
DESCRIPTION
LATCHES DISPLAY
1
Fire Zone Alarms
FI and FV Zone Alarms
Y
2
Emergency Alarms
EM Zone Alarms
Y
3
Fire Troubles and Supervisory FI, FV, and EM Troubles
Alarms and Troubles
SV Alarms and Troubles
Y
4
Burglary Zone Alarms
NT, DY, EX, and AR Zone Alarms
N
5
System Messages
Walk Test
Transmitter Missing
Transmitter Low Battery
Wireless Jamming Wireless Keypad Missing, Tamper, AC Power,
N
Low Battery, Wireless Keypad Trouble
Z-Wave Lock Low Battery
Any Other System Monitor Troubles
6
Zone Troubles
Device Missing Device Tamper
7
Late to Close Messages
System Has Not Armed as Scheduled
N
8
Armed or Ready Status
Status of Panel
N
9
Day and Time
Current Date and Time
N
10
Today’s Current Weather
Today’s Weather
N
11
Tomorrow’s Weather
Tomorrow’s Weather
N
Digital Monitoring Products | XT30INT Compliance Guide
3
Entry/Exit Delay
In System Options, set Entry Delay and Exit Delay to 30 to 45 seconds.
Transmit Delay
In Communications, Transmit Delay must be set to 30 seconds.
Bell Cutoff
In Bell Options, Bell Cutoff must be set to 2 to 15 minutes.
Power Fail
In System Options, Power Fail must be set to 1 or less.
Auto Arming the System
In Area Information, Closing Check must be ON when using Auto Arm. When arming, Closing Time! is displayed for 10 minutes and the keypad sounds. Bad zones are processed according to the Bad Zones programming in Area Information. Other troubles are automatically overridden.
Zone Expander
When using a zone expander module, one zone of the module must be used as tamper supervision.
Swinger Bypass
In System Options, SWGRBYPS TRIPS: must be set to 3 or higher.
Masking
Connect a zone to the masking contacts of a device, such as a PIR with masking contacts. Name the zone in Zone Programming X Masking where X is the name of the detector zone. For Alarm Action, set the Transmit Message to T (Trouble) for both Disarmed Open, Disarmed Short, Armed Open, and Armed Short actions.
User Codes
User codes must be at least 4-digits (0 – 9) for a total of 10,000 possible combinations.
Keypad Display Time Out
A valid User Code is required to be entered to display the Status List. The display will time out in 60 seconds with no key presses. A valid User Code will be required to be entered again to view list.
Control Panel Tamper
Wire an enclosure tamper switch to a panel zone and name the zone Panel Tamper in Zone Information. Set the Disarmed message to TRBL.
Event Recording
The Central Station must keep a list of events from the panel for 30 days. Events are stored locally in non-volatile memory. Manufacturer part number AT24C256C.
Discharge/Recharge
The XT30INT battery charging circuit float charges at 13.8 VDC at a maximum current of 1.5 Amps using a 43VA transformer. Listed below are the various battery voltage level conditions:
Battery Trouble: Below 11.9 VDC Battery Trouble: Above 12.6 VDC
The panel disconnects the battery any time the battery voltage drops below 10.2 VDC. This prevents battery deep discharge damage.
Digital Monitoring Products | XT30INT Compliance Guide
4
Closing Code
In System Options, set Closing Code to YES.
Notification Output Signals
Provides Hold-up, Tamper, and Intrusion notifications.
Operation Mode
Stores and forwards all messages to SCS-VR or SCS-1R.
Dual Path Operation
Communication takes place on the primary path with backup paths being used only when the primary path fails or when the backup path is being used to send duplicate messages.
Control Panel Unavailability
The control panel is considered unavailable when the system message 16 PANEL NOT RESPONDING is generated by the central station receiver.
Digital Monitoring Products | XT30INT Compliance Guide
5
INTERNATIONAL CERTIFICATIONS
Intertek (ETL)
EN 50130-4
EMC Product Family Standard: Immunity Requirements for Components of Fire, Intruder and Social Alarm Systems
EN 50130-5
Environmental Standards
EN 50131-1:2006+A1 Intrusion and Hold-up systems
EN 50131-3:2009
Control and Indicating Equipment
EN 50131-6:2008
Power Supplies
EN 50136-1
Alarm Transmission Systems and Equipment
EN 50136-2:2013
Supervised Premises Transceiver
EN 61000-3-2
Limits – Limits for Harmonic Current Emissions (Equip. Input Current up to and Including 16 A per Phase) Includes A1 & A2 July 1, 2009
EN 61000-3-3
Limitation of Voltage Fluctuations & Flicker in LowVoltage Supply Systems for Equip. with Rated Current Less Than or Equal to 16 A per Phase & Not Subject to Conditional Connection
EN 61000-6-4
Generic Standards – Emission Standard for Industrial Environments
DOCUMENTATION
Power Supply Security Grade EN 50131-1 Notification Requirements Environmental Class Operating Temperature Relative Humidity Weight Dimensions
Type A 2
Grade 2 Options A, B, or C II 0°C – 49°C 32°F – 120°F 80% 0.55 kg 26W x 10.5H cm
18205
Designed, engineered, and manufactured in Springfield, MO using U.S. and global components.
LT-1385INT 1.01 216424025
©© 22002244
INTRUSION · FIRE · ACCESS · NETWORKS
2500 North Partnership Boulevard Springfield, Missouri 65803-8877
417.831.9362 | DMP.com