VACON® NXP is a premium air-cooled AC drive for use in all applications where reliability, robust performance, precision and power are required. These drives are available in the power range from 0.55 kW to 2,000 kW.

Ideal for demanding applications
VACON® NXP range offers the ultimate in motor control, for both induction and permanent magnet (PM) motors, gearless drive applications and paralleling solutions for high power motors. VACON® NXP is the smart drive of choice. With fast fieldbus options and exceptional programming flexibility, your VACON® NXP is easily integrated into any plant’s automation system. Satisfied customers also rely on our enclosed cabinet drive solution, VACON® NXC, to perform in the most challenging industrial environments such as oil and gas, extrusion, mining, pulp and paper, water and wastewater applications. With improved functional safety, extensive approvals in place and comprehensive maintenance tools, you can be sure that your VACON® AC drives will give you the best possible control and ensure high operational quality and availability over the entire lifetime of your system. Our VACON® NXP portfolio fulfills key international standards and global requirements, including safety and EMC and Harmonics approvals.

In harmony with the environment
Our commitment to being a environmentally responsible company is exemplified in our energy-saving products and solutions. We have developed our manufacturing process in order to minimize the impact on the environment. All excess materials in the production and service processes are carefully sorted and recycled.

We continue to develop innovative solutions utilizing regenerative energy and smart grid technology to help customers effectively monitor and control energy use and costs. At your service Whether you are an original equipment manufacturer (OEM), system integrator, brand label customer, distributor or end user, Danfoss Drives provides services to help you meet your business targets. Our global service solutions are available 24/7 throughout the product lifecycle with the intent to minimize the total cost of ownership and environmental load.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (1) VACON® NXP/NXCDanfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (2)

Multiple options

  • VACON® NXP Control
    VACON® NXP offers a high-performance control platform for all demanding drive applications. The microcontroller provides both exceptional processing power and small footprint. The VACON® NXP supports both induction and permanent magnet motors in open and closed loop control modes. It also provides bumpless control for transferring between open loop and closed loop. VACON® Programming tool can be used to improve performance and save costs by integrating customer-specific functionality into the drive. The same control board is used in all VACON® NXP drives, allowing the maximum utilization of VACON® NXP control features over a wide power and voltage range. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (3)
  • Option boards
    Our VACON® NXP Control provides exceptional modularity by offering five (A, B, C, D and E) plug-in extension slots. Fieldbus boards, encoder boards as well as wide range of IO boards can simply be plugged-in at any time without the need to remove any other components. A listing of all options boards is provided on page 21. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (4)
  • Fieldbus options
    Your VACON® NXP is easily integrated within a plant’s automation system by using plug-in fieldbus option boards including PROFIBUS DP, Modbus RTU, DeviceNet and CANopen. Fieldbus technology ensures increased control and monitoring of the process equipment with reduced cabling – ideal for industries where the need to ensure that products are produced under the right conditions is of paramount importance. An external +24 V supply option enables communication with the control unit even if the main supply is switched off. Fast drive-to-drive communication is possible using our fast SystemBus fiber optic communication. communication is possible using our fast SystemBus fiber optic communication. Profibus DP | DeviceNet | Modbus RTU | CANopenDanfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (5)
  • Ethernet connectivity
    VACON® NXP is the smart drive of choice, as there is no need to purchase additional communication tools. Ethernet connectivity allows remote drive access for monitoring, configuring and troubleshooting. Our Ethernet protocols such as PROFINET IO, EtherNet/IP and Modbus/TCP are available for all VACON® NXP drives. New Ethernet protocols are being continuously developed.
    Modbus/TCP | PROFINET IO + System Redundancy S2 and PROFISAFE | EtherNet/IP Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (6)

Functional safety

Advanced Safety Options
The VACON Advanced Safety Options operate the safety functions of an AC drive via the PROFIsafe fieldbus or I/O control. They improve flexibility by connecting safety devices within a plant.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (7)

Safe Stop functions

  • STO – Safe Torque Off
  • SS1 – Safe Stop 1
  • SS2 – Safe Stop 2
  • SBC – Safe Brake Control
  • SQS – Safe Quick Stop

Safe Speed functions

  • SLS – Safely-limited Speed
  • SSM – Safe Speed Monitor
  • SSR – Safe Speed Range
  • SMS – Safe Maximum Speed

ATEX certified thermistor input
An ATEX approved thermistor input is available as an integrated option. Certified and compliant with the European ATEX directive 94/9/EC, the integrated thermistor input is specially designed for the temperature supervision of motors that are placed in areas in which potentially explosive gas, vapor, mist or air mixtures are present and areas with combustible dust. Typical industries requiring such supervision include chemical, petrochemical, marine, metal, mechanical, mining, and oil drilling. If oveheating is detected, the drive immediately stops feeding energy to the motor. As no external components are needed, the cabling is minimized, improving reliability and saving on both space and costs. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (8)

DC cooling fans
VACON® NXP high-performance air-cooled products are equipped with DC fans. This significantly increases the reliability and lifetime of the fan also fulfilling the ERP2015 directive on decreasing fan losses. Likewise, the DC-DC supply board component ratings fulfill industrial requirement levels. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (9)

Conformal coating
To increase performance and durability, conformally coated circuit boards (also known as varnished boards) are provided as standard for power modules (FR7 – FR14). The upgraded boards offer reliable protection against dust and moisture and extend the lifetime of the drive and critical components. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (10)

Commissioning made easy

User-friendly keypad
The user interface is intuitive to use. You will enjoy the keypad’s well-structured menu system that allows for fast commissioning and trouble-free operation.

  • Removable panel with plug-in connection
  • Graphical and text keypad with multiple language support
  • Text display multi-monitoring function
  • Parameter backup and copy function with the panel’s internal memory
  • The startup wizard ensures a hassle-free set up. Choose the language, application type and main parameters during the first power-up. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (11)

Documentation wizard
Make use of our VACON® Documentation Wizard and achieve dramatic savings in engineering time. The Documentation Wizard is a technical documentation tool, which creates a complete set of drawings for each VACON® NXC configuration. Just enter the product information, i.e. a type code, required variations and extra equipment (plus codes) into the user interface field, and the tool will automatically generate the documentation in any of the following formats: DWG (AutoCAD) drawings, DXF (AutoCAD) drawings, PDF (Adobe reader) and E-plan project (prj). Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (12)

VACON® NCDrive
VACON® NCDrive is used for setting, copying, storing, printing, monitoring and controlling parameters. The VACON® NCDrive communicates with the drive via the following interfaces: RS-232, Ethernet TCP/IP, CAN (fast multiple drive monitoring), CAN@Net (remote monitoring). VACON® NCDrive also includes a handy Datalogger function, which offers you the possibility to monitor and analyze data. PC-tools can be downloaded from http://drives.danfoss.com Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (13)

All-in-one application package
The All-in-One application package has seven built-in software applications, which can be selected with one parameter. In addition to the All-in-One package, we offer several segment specific and advanced applications such as System Interface application, Marine application, Lift application and Shaft Synchronisation application for more demanding uses. VACON® NXP applications can be downloaded from http://drives.danfoss.com

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (14)

High power and improved redundancy

VACON® DriveSync is our innovative control concept for running standard drives in parallel to control high-power AC motors or increase the redundancy of a system. This concept suits single or multiple winding motors typically above 1 MW.

Powerful AC drives can be built using standard drive components and have the following benefits:

  • The system is modular and easy to extend
  • High total power can be obtained by combining smaller drives
  • System redundancy is higher than in a conventional drive because each unit can run independently
  • Individual drive is easy to maintain and service
  • Identical units reduce the required amount of spare parts thus reducing overall costs
  • No special skills are required for the engineering, installation, commissioning and maintenance of drives as they are comprised of standard modules
  • It is possible to run multiple winding motors with a phase shift between the windings

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (15)

Typical VACON® DriveSynch examples using VACON® NXP/NXC drives

   Mains voltage    AC drive type   2 x NXC 1150 5 A 2 L 0 SSF Loadability Motor shaft power    Frame size   2 x FR13   Dimensions and weightW x H x D (mm)/kg   1606 x 2275 x 605/1350
Low (+40°C) High (+50°C)  Maximum current IS [A] 3492 400 V supply
Rated conti- nuous current IL [A]2150 10%overload current [A]2365 Rated conti- nuous current IH [A]1940 50%overload current [A]2910  10%overload P [kW] 1200  50%overload P [kW] 1100
  380-500 V50/60 Hz
2 x NXC 1300 5 A 2 L 0 SSF 2470 2717 2185 3278 3933 1350 1100
2 x NXC 1450 5 A 2 L 0 SSF 2755 3031 2470 3705 4446 1500 1350
3 x NXC 1150 5 A 2 L 0 SSF 3278 3605 2936 4403 5284 1800 1500  3 x FR13  1606 x 2275 x 605/1350
3 x NXC 1300 5 A 2 L 0 SSF 3705 4076 3278 4916 5900 2000 1800
3 x NXC 1450 5 A 2 L 0 SSF 4133 4546 3705 5558 6669 2250 2000

Values are given at switching frequency 2.0 kHz.

  Mains voltage    AC drive type   2 x NXC 0920 6 A 2 L 0 SSF Loadability Motor shaft power   Frame size   2 x FR13   Dimensions and weightW x H x D (mm)/kg   1406 x 2275 x 605/1250
Low (+40°C) High (+50°C)  Maximum current IS [A] 2679 690 V supply
Rated conti- nuous current IL [A]1748 10%overload current [A]1920 Rated conti- nuous current IH [A]1500 50%overload current [A]2337  10%overload P [kW] 1710  50%overload P [kW] 1520
  525-690 V50/60 Hz
2 x NXC 1030 6 A 2 L 0 SSF 1810 2000 1500 2337 2679 1710 1520
2 x NXC 1180 6 A 2 L 0 SSF* 1950 2140 1630 2500 3335 1900 1610
3 x NXC 0920 6 A 2 L 0 SSF 2622 2884 2337 3490 4019 2500 2200  3 x FR13  1406 x 2275 x 605/1250
3 x NXC 1030 6 A 2 L 0 SSF 2706 3000 2337 3490 4019 2500 2200
3 x NXC 1180 6 A 2 L 0 SSF* 2910 3210 2500 3735 5002 2800 2410

*Max. ambient temperature of +35°C.
Values are given at switching frequency 2.0 kHz.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (16)

VACON® NXP wall-mounted

The VACON® NXP wall-mounted is one of the most compact and comprehensive drive packages on the market, with all the necessary components integrated in a single frame. For the lower power range, VACON® NXP drives are available in a compact IP21 or IP54 frame.

Fully equipped
VACON® NXP wall-mounted units are equipped with internal EMC filtering and the power electronics are integrated into an all-metal frame. The smaller frame sizes (FR4-FR6) have an integrated brake chopper as standard and the 380-500 V units can be equipped with an integrated brake resistor. The larger frames (FR7-FR12) can be equipped with an integrated brake chopper as an option.

Typical applications

  • Elevators and escalators
  • Cranes and hoists
  • Winches and cargo pumps
  • Pumps and fans
  • Conveyors
  • Machine tools
  • Yaw and pitch control
  • Oil pumps
  • Winders and unwinders
  • Pulp dryers
  • Tissue machinery
  • Extruders

Features

  • Complete voltage range 230…690 V AC
  • Removable panel with parameter back-up function
  • Common control board
  • Built-in I/0 expandability, 5 slots available and option boards in all frame sizes
  • Marine type approvals and functional safety features
  • Integrated brake chopper as standard in FR4-6, 380-500 V units.

Benefits

  • One type of drive for wide power and voltage range reduces the complexity and the need for additional training
  • Easier commissioning – saves time
  • Same software tools and applications for the entire range
  • Compact and easy to install –saves time and money
  • System complexity can be reduced saving engineering time and costs

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (18) Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (19)

Ratings and dimensions

Mains voltage

AC drive typeNXP 0003 2 A 2 H 1 S S S Loadability Motor shaft power Frame sizeFR4 Dimensions and weightW x H x D (mm)/ kg128 x 292 x 190/ 5
Low (+40°C) High (+50°C) Maximum current IS [A]4.8 230 V / 400 V/ 690 V
Rated continuous current IL [A]3.7 10%overload current [A]4.1 Rated continuous current IH [A]2.4 50%overload current [A]3.6 10%overload P [kW]0.55 50%overload P [kW]0.37
208-240 V50/60 Hz
NXP 0004 2 A 2 H 1 S S S 4.8 5.3 3.7 5.6 7.4 0.75 0.55
NXP 0007 2 A 2 H 1 S S S 6.6 7.3 4.8 7.2 9.6 1.1 0.75
NXP 0008 2 A 2 H 1 S S S 7.8 8.6 6.6 9.9 13.2 1.5 1.1
NXP 0011 2 A 2 H 1 S S S 11 12.1 7.8 11.7 15.6 2.2 1.5
NXP 0012 2 A 2 H 1 S S S 12.5 13.8 11 16.5 22 3 2.2
NXP 0017 2 A 2 H 1 S S S 17.5 19.3 12.5 18.8 25 4 3 FR5 144 x 391 x 214/ 8.1
NXP 0025 2 A 2 H 1 S S S 25 27.5 17.5 26.3 35 5.5 4
NXP 0031 2 A 2 H 1 S S S 31 34.1 25 37.5 50 7.5 5.5
NXP 0048 2 A 2 H 1 S S S 48 52.8 31 46.5 62 11 7.5 FR6 195 x 519 x 237/ 18.5
NXP 0061 2 A 2 H 1 S S S 61 67.1 48 72 96 15 11
NXP 0075 2 A 2 H 0 S S S 75 83 61 92 122 22 15 FR7 237 x 591 x 257/ 35
NXP 0088 2 A 2 H 0 S S S 88 97 75 113 150 22 22
NXP 0114 2 A 2 H 0 S S S 114 125 88 132 176 30 22
NXP 0140 2 A 2 H 0 S S S 140 154 105 158 210 37 30 FR8 291 x 758 x 344/ 58
NXP 0170 2 A 2 H 0 S S S 170 187 140 210 280 45 37
NXP 0205 2 A 2 H 0 S S S 205 226 170 255 336 55 45
NXP 0261 2 A 2 H 0 S S F 261 287 205 308 349 75 55 FR9 480 x 1150 x 362/ 146
NXP 0300 2 A 2 H 0 S S F 300 330 245 368 444 90 75
380-500 V50/60 Hz 3˜ NXP 0003 5 A 2 H 1 S S S 3.3 3,6 2,2 3,3 4,4 1,1 0,75 FR4 128 x 292 x 190/ 5
NXP 0004 5 A 2 H 1 S S S 4,3 4,7 3,3 5 6,2 1,5 1,1
NXP 0005 5 A 2 H 1 S S S 5,6 6,2 4,3 6,5 8,6 2,2 1,5
NXP 0007 5 A 2 H 1 S S S 7,6 8,4 5,6 8,4 10,8 3 2,2
NXP 0009 5 A 2 H 1 S S S 9 9,9 7,6 11,4 14 4 3
NXP 0012 5 A 2 H 1 S S S 12 13,2 9 13,5 18 5,5 4
NXP 0016 5 A 2 H 1 S S S 16 17,6 12 18 24 7,5 5,5 FR5 144 x 391 x 214/8.1
NXP 0022 5 A 2 H 1 S S S 23 25,3 16 24 32 11 7,5
NXP 0031 5 A 2 H 1 S S S 31 34 23 35 46 15 11
NXP 0038 5 A 2 H 1 S S S 38 42 31 47 62 18,5 15 FR6 195 x 519 x 237/18.5
NXP 0045 5 A 2 H 1 S S S 46 51 38 57 76 22 18,5
NXP 0061 5 A 2 H 1 S S S 61 67 46 69 92 30 22
NXP 0072 5 A 2 H 0 S S S 72 79 61 92 122 37 30 FR7 237 x 591 x 257/35
NXP 0087 5 A 2 H 0 S S S 87 96 72 108 144 45 37
NXP 0105 5 A 2 H 0 S S S 105 116 87 131 174 55 45
NXP 0140 5 A 2 H 0 S S S 140 154 105 158 210 75 55 FR8 291 x 758 x 344/58
NXP 0168 5 A 2 H 0 S S S 170 187 140 210 280 90 75
NXP 0205 5 A 2 H 0 S S S 205 226 170 255 336 110 90
NXP 0261 5 A 2 H 0 S S F 261 287 205 308 349 132 110 FR9 480 x 1150 x 362/146
NXP 0300 5 A 2 H 0 S S F 300 330 245 368 444 160 132
525-690 V50/60 Hz 3˜ NXP 0004 6 A 2 L 0 S S S 4,5 5 3,2 4,8 6,4 3 2,2 FR6 195 x 519 x 237/18.5
NXP 0005 6 A 2 L 0 S S S 5,5 6,1 4,5 6,8 9 4 3
NXP 0007 6 A 2 L 0 S S S 7,5 8,3 5,5 8,3 11 5,5 4
NXP 0010 6 A 2 L 0 S S S 10 11 7,5 11,3 15 7,5 5,5
NXP 0013 6 A 2 L 0 S S S 13,5 14,9 10 15 20 11 7,5
NXP 0018 6 A 2 L 0 S S S 18 19,8 13,5 20,3 27 15 11
NXP 0022 6 A 2 L 0 S S S 22 24,2 18 27 36 18,5 15
NXP 0027 6 A 2 L 0 S S S 27 29,7 22 33 44 22 18,5
NXP 0034 6 A 2 L 0 S S S 34 37 27 41 54 30 22
NXP 0041 6 A 2 L 0 S S S 41 45 34 51 68 37,5 30 FR7 237 x 591 x 257/35
NXP 0052 6 A 2 L 0 S S S 52 57 41 62 82 45 37,5
NXP 0062 6 A 2 L 0 S S S 62 68 52 78 104 55 45 FR8 291 x 758 x 344/58
NXP 0080 6 A 2 L 0 S S S 80 88 62 93 124 75 55
NXP 0100 6 A 2 L 0 S S S 100 110 80 120 160 90 75
NXP 0125 6 A 2 L 0 S S F 125 138 100 150 200 110 90 FR9 480 x 1150 x 362/146
NXP 0144 6 A 2 L 0 S S F 144 158 125 188 213 132 110
NXP 0170 6 A 2 L 0 S S F 170 187 144 216 245 160 132
NXP 0208 6 A 2 L 0 S S F 208 229 170 255 289 200 160

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (20)

VACON® NXP drive module
VACON® NXP high-power IP00 drive modules are intended for installation into a cabinet, switchgear or any separate enclosure. Module installation in standard enclosures is easy given the compact design.

Designed to fit
VACON® NXP drive modules of frame size FR10 – FR12 embody one (FR10 and FR11) or two (FR12) power modules. VACON® NXP frame sizes FR13 – FR14 comprise two to four non-regenerative front-end (NFE) units and one (FR13) or two (FR14) inverter units. External AC chokes are also included in the delivery. The VACON® NXP modules are available as both 6-pulse and
12-pulse supply versions.

Typical applications

  • Conveyors
  • Cranes and lifts
  • High-speed compressors
  • Ski lifts
  • Main propulsion and bow thrusters
  • Extruders
  • Winches & cargo pumps
  • Oil pumps
  • Test benches
  • Static power supply
  • Grinders and mixers
  • Winders and unwinders
  • Chippers
  • Tunneling Machines

Features

  • Easy cabinet integration with additional assembly kits
  • One of the smallest on the market
  • Extensive marine type approvals
  • VACON® DriveSynch features

Benefits

  • With optimized module design, less engineering is needed saving time and money
  • Compact module size require less cabinet space, while reducing the overall costs
  • Improved redundancy and higher powers up to 5 MW

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (21)

Hardware configurations

Function Availability
Integrated control Standard
External control Optional
Integrated brake chopper Optional (FR 10-12)
6-Pulse Supply Standard
12-Pulse Supply Optional
EMC filtering N Standard
EMC filtering T (for IT -networks) AC choke Output filters dU/dt, Sine and common mode Optional Standard Optional

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (22)

Ratings and dimensions

Loadability Motor shaft power
Low (+40°C) High (+40°C) Maxi- mum current IS[A]540 400 V / 690 V
Mains voltage AC drive type Rated conti- nuous current IL [A] 10%over- load current [A] Rated conti- nuous current IH [A] 50%over- load current [A] 10%over- loadP [kW] 50%over- loadP [kW] Frame size Module W x H x D (mm)/ kg Chokes W x H x D (mm)/ kg
NXP 0385 5 A 0 N 0 SSA 385 424 300 450 200 160 350 x 383 x 262/84 1)
NXP 0460 5 A 0 N 0 SSA 460 506 385 578 693 250 200 FR10 500 x 1165 x 506/120 497 x 399 x 244/115 1)
NXP 0520 5 A 0 N 0 SSA* 520 572 460 690 828 250 250 497 x 399 x 244/115 1)
NXP 0590 5 A 0 N 0 SSA 590 649 520 780 936 315 250 FR11 709 x 1206 x 506/210 2 x (350 x 383 x 262/84)
NXP 0650 5 A 0 N 0 SSA 650 715 590 885 1062 355 315
NXP 0730 5 A 0 N 0 SSA 730 803 650 975 1170 400 355
NXP 0820 5 A 0 N 0 SSA 820 902 730 1095 1314 450 400
NXP 0920 5 A 0 N 0 SSA 920 1012 820 1230 1476 500 450 FR12 2 x (500 x 1165 x 506/120) 2 x (497 x 399 x 244/115)
380-500 V NXP 1030 5 A 0 N 0 SSA 1030 1133 920 1380 1656 560 500
NXP 1150 5 A 0 N 0 SSF 1150 1265 1030 1545 1854 630 560 2 x (497 x 449 x 249/130)
50/60 Hz 2 x (239 x 1030 x 372/67) +
1 x (708 x 1030 x 553/302)
NXP 1300 5 A 0 N 0 SSF 1300 1430 1150 1725 2070 710 630 FR13 3 x (239 x 1030 x 372/67) +1 x (708 x 1030 x 553/302) 2) 3 x (497 x 449 x 249/130) 2)
NXP 1450 5 A 0 N 0 SSF 1450 1595 1300 1950 2340 800 710 3 x (239 x 1030 x 372/67) + 3 x (497 x 449 x 249/130) 2)
1 x (708 x 1030 x 553/302) 2)
NXP 1770 5 A 0 N 0 SSF 1770 1947 1600 2400 2880 1000 900 4 x (239 x 1030 x 372/67) + 4 x (497 x 449 x 249/130)
FR14 2 x (708 x 1032 x 553/302)
NXP 2150 5 A 0 N 0 SSF 2150 2365 1940 2910 3492 1200 1100 4 x (239 x 1030 x 372/67) + 4 x (497 x 449 x 249/130)
2 x (708 x 1032 x 553/302)
NXP 0261 6 A 0 N 0 SSA 261 287 208 312 375 250 200 FR10 500 x 1165 x 506/120 354 x 319 x 230/53 3)
NXP 0325 6 A 0 N 0 SSA 325 358 261 392 470 315 250 500 x 1165 x 506/120 350 x 383 x 262/84 3)
NXP 0385 6 A 0 N 0 SSA 385 424 325 488 585 355 315 500 x 1165 x 506/120 350 x 383 x 262/84 3)
NXP 0416 6 A 0 N 0 SSA* 416 458 325 488 585 400 315 500 x 1165 x 506/120 350 x 383 x 262/84 3)
NXP 0460 6 A 0 N 0 SSA 460 506 385 578 693 450 355 FR11 709 x 1206 x 506/210 497 x 399 x 244/115 4)
NXP 0502 6 A 0 N 0 SSA 502 552 460 690 828 500 450 709 x 1206 x 506/210 497 x 399 x 244/115 4)
NXP 0590 6 A 0 N 0 SSA* 590 649 502 753 904 560 500 709 x 1206 x 506/210 2 x (350 x 383 x 262/84)
NXP 0650 6 A 0 N 0 SSA 650 715 590 885 1062 630 560 2 x (500 x 1165 x 506/120) 2 x (350 x 383 x 262/84)
NXP 0750 6 A 0 N 0 SSA 750 825 650 975 1170 710 630 FR12 2 x (500 x 1165 x 506/120) 2 x (350 x 383 x 262/84)
525-690 V50/60 Hz NXP 0820 6 A 0 N 0 SSA* 820 902 650 975 1170 800 630 2 x (500 x 1165 x 506/120) 2 x (350 x 383 x 262/84)
NXP 0920 6 A 0 N 0 SSF 920 1012 820 1230 1410 900 800 FR13 2 x (239 x 1030 x 372/67) +1 x (708 x 1030 x 553/302) 2 x (497 x 449 x 249/130)
NXP 1030 6 A 0 N 0 SSF 1030 1133 920 1380 1755 1000 900 2 x (239 x 1030 x 372/67) +1 x (708 x 1030 x 553/302) 2 x (497 x 449 x 249/130)
NXP 1180 6 A 0 N 0 SSF* 1180 1298 1030 1463 1755 1150 1000 2 x (239 x 1030 x 372/67) + 2 x (497 x 449 x 249/130)
1 x (708 x 1030 x 553/302)
NXP 1500 6 A 0 N 0 SSF 1500 1650 1300 1950 2340 1500 1300 3 x (239 x 1030 x 372/67) + 3 x (497 x 449 x 249/130) 5)
2 x (708 x 103 x 553/302) 3)
NXP 1900 6 A 0 N 0 SSF 1900 2090 1500 2250 2700 1800 1500 FR14 4 x(239 x 1030 x 372/67) +2 x (708 x 1030 x 553/302) 4 x (497 x 449 x 249/130)
NXP 2250 6 A 0 N 0 SSF* 2250 2475 1900 2782 3335 2000 1800 4 x (239 x 1030 x 372/67) + 4 x (497 x 449 x 249/130)
2 x (708 x 1030 x 553/302)

*Max. ambient temperature of +35°C.

  1. 12-pulse units, 2 x (354 x 319 x 230/53 kg)
  2. 12-pulse units, 4 x (497 x 449 x 249/130 kg)
  3. 12-pulse units, 2 x (354 x 319 x 230/53 kg)
  4. 12-pulse units, 4 x (239 x 1030 x 372/67) + 2 x (708 x 1030 x 372/302 kg)
  5. 12-pulse units, 4 x (497 x 449 x 249/130 kg)

 

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (23)

VACON® NXP standalone
Premium VACON® NXP drives are also available in standalone IP21 or IP54 enclosures. These units are delivered in a compact enclosure, making them perfect for areas with limited space, while still providing full VACON® NXP control flexibility.

Robust and reliable
VACON® NXP standalone drives are fully enclosed at the factory and ready for immediate installation. The drive is ideal for pumps, fans and other single drive applications. The drive has integrated fuses as standard and no extra protection components are required. It is also possible to equip the drive with an optional integrated load switch, which further simplifies handling in the field.

Typical applications

  • Auxiliary equipment
  • Pump and fans
  • Main propulsion and bow thrusters
  • Compressors
  • Cranes and lifts

Features

  • Extremely compact cabinet enclosure
  • Delivered with ultra rapid AC fuses
  • Optional built-in brake chopper and
  • DC-link connectors

Benefits

  • Maximize the utilization of available space while reducing the overall costs
  • No need to consider any additional protection componentsDanfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (24)

Hardware configurations

Function Availability
IP21 Standard
IP54 (FR10 only) Optional (H: +20mm)
Integrated ultra rapid fuses Standard
Load switch (IEC or UL version) Optional
EMC filtering L (EN 61800-3, category C3) Standard
EMC filtering T (for IT -networks) Optional
Brake chopper (cabling top entry) Optional(H: +122 mm)

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (25)Ratings and dimensions

 

 

Mains voltage

 

 

 

AC drive type

 

 

 

NXP 0385 5 A 2 L 0 SSA

Loadability Motor shaft power  

 

Frame size

 

 

 

FR10

 

 

Dimensions and weight

W x H x D (mm)/ kg

 

 

 

595 x 2020 x 602/340

Low (+40°C) High (+40°C)  

Maximum current IS [A]

 

540

400 V / 690 V
Rated conti- nuous current IL [A]

385

10%

overload current [A]

424

Rated conti- nuous current IH [A]

300

50%

overload current [A]

450

 

10%

overload P [kW]

 

200

 

50%

overload P [kW]

 

160

 

380-500 V

50/60 Hz

NXP 0460 5 A 2 L 0 SSA 460 506 385 578 693 250 200
NXP 0520 5 A 2 L 0 SSA* 520 572 460 690 828 250 250
NXP 0590 5 A 2 L 0 SSA 590 649 520 780 936 315 250  

FR11

 

794 x 2020 x 602/470

NXP 0650 5 A 2 L 0 SSA 650 715 590 885 1062 355 315
NXP 0730 5 A 2 L 0 SSA 730 803 650 975 1170 400 355
 

 

525-690 V

50/60 Hz

NXP 0261 6 A 2 L 0 SSA

NXP 0325 6 A 2 L 0 SSA

NXP 0385 6 A 2 L 0 SSA

NXP 0416 6 A 2 L 0 SSA*

261 287 208 312 375 250 200  

FR10

 

595 x 2020 x 602/340

325 358 261 392 470 315 250
385 424 325 488 585 355 315
416 458 325 488 585 400 315
NXP 0460 6 A 2 L 0 SSA

NXP 0502 6 A 2 L 0 SSA

NXP 0590 6 A 2 L 0 SSA*

460 506 385 578 693 450 355  

FR11

794 x 2020 x 602/400

794 x 2020 x 602/400

794 x 2020 x 602/470

502 552 460 690 828 500 450
590 649 502 753 904 560 500

*Max. ambient temperature of +35°C.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (26)

VACON® NXC

Our VACON® NXC is designed to meet the most demanding requirements for flexibility, robustness, compactness and service-friendliness. It is a safe choice for any application and available in the 160 to 2000 kW power range and 380-500 V, 525-690 V voltage range.

  • Exceptional performance
    Our enclosed VACON® NXC variable speed AC drives are compact and well tested to meet harsh operating conditions. They are typically put to work in segments, such as mining, oil and gas, water and wastewater. The reliable thermal handling of the enclosure guarantees extended lifetime of the frequency converter and trouble-free operation in tough environments. Approved EMC solutions ensure reliable operation of the converter without disturbing other electrical equipment.Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (27)
  • User-friendly
    VACON® NXC features an easily accessible control compartment for relays, auxiliary terminals and other equipment and ample space around the power terminals allows for easy installation and connection of power cables. Our handy keypad is located on the door with additional door options including indicators, meters and switches. Bottom plates and earthing claps for 360 degree earthing of motor cables are provided as standard.
  • Service-friendly
    VACON® NXC enclosures are easy to install with lifting lugs for easy handling and can be wall-mounted or free-standing. VACON® NXP power units are rail-mounted for easy pull-out, and the optional pull-out jig enables hassle-free servicing of the power unit. No additional cooling fans are required in the enclosure IP21/IP54 and the fans can be easily replaced without having to remove the power unit.

Typical applications

  • Pumps and fans
  • Extruders
  • Main propulsion and bow thrusters
  • Wood handling machines
  • Conveyors and crushers
  • Feeders and mixers
  • Test benches
  • Water treatment
  • Winches
  • Compressors
  • Static power supply
  • Industrial elevators

Features

  • Robust and type-tested design
  • Wide range of standard options
  • One of the most compact on the market
  • Welded Rittal TS8 frame
  • EMC approved (EN61800-3, 2nd env.)
  • Service concept with pullout jig
  • No additional fans in IP54 enclosure

Benefits

  • Trouble free installation and operation
  • Adapts to your needs w/o engineering
  • Easy to fit into small spaces
  • Global enclosure availability
  • Easy to extend
  • Fast service and easy maintenanceDanfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (28)

Ratings and dimensions
VACON® NXC, 6-pulse supply

Loadability Motor shaft power  

 

Frame size

 

 

 

FR9

 

 

Dimensions and weight

W x H x D (mm)/ kg

 

 

606 x 2275 x 605/371

Low (+40°C) High (+40°C) 400 V / 690 V
Mains voltage  

AC drive type

Rated conti- nuous current IL [A] 10%

overload current [A]

Rated conti- nuous current IH [A] 50%

overload current [A]

Maximum current IS [A]  

10%

overload P [kW]

 

50%

overload P [kW]

NXC 0261 5 A 2 H 0 SSF 261 287 205 308 349 132 110
NXC 0300 5 A 2 H 0 SSF 300 330 245 368 444 160 132
NXC 0385 5 A 2 L 0 SSF 385 424 300 450 540 200 160  

FR10

 

606 x 2275 x 605/403

NXC 0460 5 A 2 L 0 SSF 460 506 385 578 693 250 200
NXC 0520 5 A 2 L 0 SSF* 520 572 460 690 828 250 250
NXC 0590 5 A 2 L 0 SSF 590 649 520 780 936 315 250
380-500 V NXC 0650 5 A 2 L 0 SSF 650 715 590 885 1062 355 315 FR11 806 x 2275 x 605/577
NXC 0730 5 A 2 L 0 SSF 730 803 650 975 1170 400 355
50/60 Hz

NXC 0820 5 A 2 L 0 SSF

NXC 0920 5 A 2 L 0 SSF

820

920

902

1012

730

820

1095

1230

1314

1476

450

500

400

450

 

FR12

 

1206 x 2275 x 605/810

NXC 1030 5 A 2 L 0 SSF 1030 1133 920 1380 1656 560 500
NXC 1150 5 A 2 L 0 SSF 1150 1265 1030 1545 1854 630 560 1406 x 2275 x 605/1000
NXC 1300 5 A 2 L 0 SSF 1300 1430 1150 1725 2070 710 630 FR13 1606 x 2275 x 605/1150
NXC 1450 5 A 2 L 0 SSF 1450 1595 1300 1950 2340 800 710 1606 x 2275 x 605/1150
NXC 1770 5 A 2 L 0 SSF 1770 1947 1600 2400 2880 1000 900 FR14 2806 x 2275 x 605/2440
NXC 2150 5 A 2 L 0 SSF 2150 2365 1940 2910 3492 1200 1100
NXC 0125 6 A 2 L 0 SSF 125 138 100 150 200 110 90  

FR9

 

606 x 2275 x 605/371

NXC 0144 6 A 2 L 0 SSF 144 158 125 188 213 132 110
NXC 0170 6 A 2 L 0 SSF 170 187 144 216 245 160 132
NXC 0208 6 A 2 L 0 SSF 208 229 170 255 289 200 160
NXC 0261 6 A 2 L 0 SSF 261 287 208 312 375 250 200
NXC 0325 6 A 2 L 0 SSF

NXC 0385 6 A 2 L 0 SSF

325

385

358

424

261

325

392

488

470

585

315

355

250

315

FR10 606 x 2275 x 605/371
NXC 0416 6 A 2 L 0 SSF* 416 458 325 488 585 400 315
525-690 V

50/60 Hz

NXC 0460 6 A 2 L 0 SSF 460 506 385 578 693 450 355  

FR11

806 x 2275 x 605/524
NXC 0502 6 A 2 L 0 SSF 502 552 460 690 828 500 450
NXC 0590 6 A 2 L 0 SSF* 590 649 502 753 904 560 500 806 x 2275 x 605/577
NXC 0650 6 A 2 L 0 SSF 650 715 590 885 1062 630 560  

FR12

 

1206 x 2275 x 605/745

NXC 0750 6 A 2 L 0 SSF 750 825 650 975 1170 710 630
NXC 0820 6 A 2 L 0 SSF* 820 902 650 975 1170 800 630
NXC 0920 6 A 2 L 0 SSF 920 1012 820 1230 1410 900 800  

FR13

 

1406 x 2275 x 605/1000

NXC 1030 6 A 2 L 0 SSF 1030 1133 920 1380 1755 1000 900
NXC 1180 6 A 2 L 0 SSF* 1180 1298 1030 1463 1755 1150 1000
NXC 1500 6 A 2 L 0 SSF 1500 1650 1300 1950 2340 1500 1300  

FR14

2406 x 2275 x 605/2350
NXC 1900 6 A 2 L 0 SSF 1900 2090 1500 2250 2700 1800 1500 2806 x 2275 x 605/2440
NXC 2250 6 A 2 L 0 SSF* 2250 2475 1900 2782 3335 2000 1800 2806 x 2275 x 605/2500

*Max. ambient temperature of +35°C.

Ratings and dimensions
VACON® NXC, 12 -pulse supply

Loadability Motor shaft power
Low (+40°C) High (+40°C) 400 V / 690 V
Mains voltage  AC drive type Rated conti- nuous current IL [A] 10%overload current [A] Rated conti- nuous current IH [A] 50%overload current [A] Maximum current IS [A]  10%overload P [kW]  50%overload P [kW] Frame size Dimensions and weightW x H x D (mm)/ kg
NXC 0385 5 A 2 L 0 TSF 385 424 300 450 540 200 160 606 x 2275 x 605/371
NXC 0460 5 A 2 L 0 TSF 460 506 385 578 693 250 200 FR10 606 x 2275 x 605/403
NXC 0520 5 A 2 L 0 TSF* 520 572 460 690 828 250 250 606 x 2275 x 605/403
NXC 0590 5 A 2 L 0 TSF 590 649 520 780 936 315 250 806 x 2275 x 605/ 577
NXC 0650 5 A 2 L 0 TSF 650 715 590 885 1062 355 315 FR11 806 x 2275 x 605/577
380-500 V NXC 0730 5 A 2 L 0 TSF 730 803 650 975 1170 400 355 806 x 2275 x 605/577
NXC 0820 5 A 2 L 0 TSF 820 902 730 1095 1314 450 400 1206 x 2275 x 605/810
50/60 Hz FR12
NXC 0920 5 A 2 L 0 TSF 920 1012 820 1230 1476 500 450 1206 x 2275 x 605/810
NXC 1030 5 A 2 L 0 TSF 1030 1133 920 1380 1656 560 500 1206 x 2275 x 605/810
NXC 1150 5 A 2 L 0 TSF 1150 1265 1030 1545 1854 630 560 1406 x 2275 x 605/1000
NXC 1300 5 A 2 L 0 TSF 1300 1430 1150 1725 2070 710 630 FR13 2006 x 2275 x 605/1150
NXC 1450 5 A 2 L 0 TSF 1450 1595 1300 1950 2340 800 710 2006 x 2275 x 605/1150
NXC 1770 5 A 2 L 0 TSF 1770 1947 1600 2400 2880 1000 900 FR14 2806 x 2275 x 605/2440
NXC 2150 5 A 2 L 0 TSF 2150 2365 1940 2910 3492 1200 1100 2806 x 2275 x 605/2500
      525-690 V50/60 Hz NXC 0261 6 A 2 L 0 TSF 261 287 208 312 375 250 200  FR10 606 x 2275 x 605/341
NXC 0325 6 A 2 L 0 TSF 325 358 261 392 470 315 250 606 x 2275 x 605/371
NXC 0385 6 A 2 L 0 TSF 385 424 325 488 585 355 315 606 x 2275 x 605/371
NXC 0416 6 A 2 L 0 TSF* 416 458 325 488 585 400 315 606 x 2275 x 605/403
NXC 0460 6 A 2 L 0 TSF 460 506 385 578 693 450 355  FR11 806 x 2275 x 605/524
NXC 0502 6 A 2 L 0 TSF 502 552 460 690 828 500 450 806 x 2275 x 605/524
NXC 0590 6 A 2 L 0 TSF* 590 649 502 753 904 560 500 806 x 2275 x 605/577
NXC 0650 6 A 2 L 0 TSF 650 715 590 885 1062 630 560  FR12 1206 x 2275 x 605/745
NXC 0750 6 A 2 L 0 TSF 750 825 650 975 1170 710 630 1206 x 2275 x 605/745
NXC 0820 6 A 2 L 0 TSF* 820 902 650 975 1170 800 630 1206 x 2275 x 605/745
NXC 0920 6 A 2 L 0 TSF 920 1012 820 1230 1410 900 800  FR13 1406 x 2275 x 605/1000
NXC 1030 6 A 2 L 0 TSF 1030 1133 920 1380 1755 1000 900 1406 x 2275 x 605/1000
NXC 1180 6 A 2 L 0 TSF* 1180 1298 1030 1463 1755 1150 1000 1406 x 2275 x 605/1000
NXC 1500 6 A 2 L 0 TSF 1500 1650 1300 1950 2340 1500 1300  FR14 2806 x 2275 x 605/2440
NXC 1900 6 A 2 L 0 TSF 1900 2090 1500 2250 2700 1800 1500 2806 x 2275 x 605/2440
NXC 2250 6 A 2 L 0 TSF* 2250 2475 1900 2782 3335 2000 1800 2806 x 2275 x 605/2500

*Max. ambient temperature of +35°C.

Hardware configurations, 6-pulse supply

6-pulse Enclosure EMC Brake chopper Cabling Input device Output filters
380-500 V IP21 IP54 L T H Bottom Top

+CIT/+COT

+IFU +ILS +IFD +ICO +ICB +OCM/

+OCH

+ODU +OSI
FR9 S O (H: +130) S O O S O (W: +400) O O O O O O O O (W: +600)
FR10 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600)
FR11 S O (H: +130)* S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600-800)
FR12 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +1200)
FR13 S O (H: +170) S O 1 S O (W: +400) S O O O O (W: +800)
FR14 S O (H: +170) S O 1 S O (W: +600) S O S O (W: +1600)
500-690 V
FR9 S O (H: +130) S O O S O (W: +400) O O O O O O O O (W: +600)
FR10 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600)
FR11 S O (H: +130)* S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600-800)
FR12 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +1200)
FR13 S O (H: +170) S O 1 S O (W: +400) S O O O O (W: +800)
FR14 S O (H: +170) S O 1 S O (W: +600) S O S O (W: +1600)

S = Standard O = Optional
1)(W: +400) = Contact factory*NXC07305 and NXC05906, H: +170 mm

Hardware configurations, 12-pulse supply

12-pulse Enclosure EMC Brake chopper Cabling Input device Output filters
380-500 V IP21 IP54 L T H Bottom Top

+CIT/+COT

+IFU +ILS +IFD +ICO +ICB +OCM/

+OCH

+ODU +OSI
FR10 S O (H: +130) S O S O (W: +400) O O O O (W: +400) O (W: +600)
FR11 S O (H: +130)* S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600)
FR12 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +1200)
FR13 S O (H: +170) S O 1 S O (W: +400) S O O O (W: +800)
FR14 S O (H: +170) S O 1 S O (W: +800) S O S O (W: +1600)
500-690 V
FR10 S O (H: +130) S O S O (W: +400) O O O O (W: +400) O (W: +600)
FR11 S O (H: +130)* S O O S O (W: +400) O O O O O O O (W: +400) O (W: +600-800)
FR12 S O (H: +130) S O O S O (W: +400) O O O O O O O (W: +400) O (W: +1200)
FR13 S O (H: +170) S O 1 S O (W: +400) S O O O (W: +800)

S = Standard O = Optional
1)(W: +400) = Contact factory
*NXC07305 and NXC05906, H: +170 mm

Pure performance
Rising energy prices, environmental legislation and process improvement are key issues when designing water handling systems. Use of VACON® AC drives for flow and pressure control instead of dampers or valves gives substantial energy savings resulting in quick ROI.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (29)

VACON® NXC Low Harmonic
The VACON® NXC Low Harmonic drive is the perfect choice for applications where low harmonics are required. This drive not only meets the most demanding requirements for clean power but also provides other important benefits such as regenerative braking and voltage boost for maximum output power.

Clean power saves money
The low harmonic cabinet drive offers an excellent total solution to meet even the most demanding power quality requirements. The drive also complies with the IEEE-519, G5/4 harmonic standards. The low THDi reduces supply currents and allows supply transformers, protection devices and power cables to be dimensioned according to the actual active power. It creates savings for both new and retrofit projects as there’s no need to invest in expensive 12- or 18-pulse transformers.

Typical applications

  • Pumps and fans
  • Water treatment
  • Thrusters and main propulsion
  • Crushers and conveyors and mills
  • Industrial elevators
  • Test benches
  • Sugar refineries

Features

  • Clean power with total current harmonics THDi < 5 %
  • Over-dimensioning of power transformer or input cables is not required
  • Regenerative function available
  • Reducing system complexity
  • No need for special 12-pulse transformers
  • Well-suited for retrofit projects
  • Increased flexibility with a wide range of standard options

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (30)

Benefits

  • Over-dimensioning of input components is not needed, reducing the total costs
  • Voltage boost function for maximum output power
  • Braking energy can be fed back to network saving energy costs
  • Reduces overall investment costs and optimizes the use of available space

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (31)

Ratings and dimensions

Mains voltage

Low harmonic drive type

NXC 0261 5 A 2 L 0 RSF

Loadability Motor shaft power Frame size

AF9

Dimensions and weightW x H x D (mm)/ kg

1006 x 2275 x 605/680

Low (+40°C) High (+40°C) Maximum current IS [A]
349
400 V / 690 V
Rated conti- nuous current IL [A]261 10%overload current [A]287 Rated conti- nuous current IH [A]205 50%overload current [A]308 10%overload P [kW]
132
50%overload P [kW]
110
380-500 V50/60 Hz
NXC 0300 5 A 2 L 0 RSF 300 330 245 368 444 160 132
NXC 0385 5 A 2 L 0 RSF 385 424 300 450 540 200 160 AF10 1006 x 2275 x 605/700
NXC 0460 5 A 2 L 0 RSF 460 506 385 578 693 250 200
NXC 0520 5 A 2 L 0 RSF* 520 572 460 690 828 250 250
NXC 0650 5 A 2 L 0 RSF 650 715 590 885 1062 355 315 AF12 2006 x 2275 x 605/1400
NXC 0730 5 A 2 L 0 RSF 730 803 650 975 1170 400 355
NXC 0820 5 A 2 L 0 RSF 820 902 730 1095 1314 450 400
NXC 0920 5 A 2 L 0 RSF 920 1012 820 1230 1476 500 450
NXC 1030 5 A 2 L 0 RSFNXC 1150 5 A 2 L 0 RSFNXC 1300 5 A 2 L 0 RSFNXC 1450 5 A 2 L 0 RSFNXC 1770 5 A 2 L 0 RSF 10301150130014501770 11331265143015951947 9201030115013001600 13801545172519502400 16561854207023402880 5606307108001000 500560630710900 AF13 2206 x 2275 x 605/1950
NXC 2150 5 A 2 L 0 RSF 2150 2365 1940 2910 3492 1200 1100 AF14 4406 x 2275 x 605/3900
NXC 2700 5 A 2 L 0 RSFNXC 0125 6 A 2 L 0 RSFNXC 0144 6 A 2 L 0 RSFNXC 0170 6 A 2 L 0 RSFNXC 0208 6 A 2 L 0 RSF* 2700125144170208 2970138158187229 2300100125144170 3278150188216255 3933200213245289 1500110132160200 120090110132160 AF9 1006 x 2275 x 605/680
525-690 V50/60 Hz
NXC 0261 6 A 2 L 0 RSF 261 287 208 312 375 250 200 AF10 1006 x 2275 x 605/700
NXC 0325 6 A 2 L 0 RSF 325 358 261 392 470 315 250
NXC 0385 6 A 2 L 0 RSF 385 424 325 488 585 355 315
NXC 0416 6 A 2 L 0 RSF*NXC 0460 6 A 2 L 0 RSFNXC 0502 6 A 2 L 0 RSFNXC 0590 6 A 2 L 0 RSFNXC 0650 6 A 2 L 0 RSFNXC 0750 6 A 2 L 0 RSFNXC 0820 6 A 2 L 0 RSF* 416460502590650750820 416506552649715825902 325385460502590650650 488578690753885975975 585693828904106211701170 400450500560630710750 315355450500560630650 AF12 2006 x 2275 x 605/1400
NXC 0920 6 A 2 L 0 RSF 920 1012 820 1230 1476 900 800 AF13 2206 x 2275 x 605/1950
NXC 1030 6 A 2 L 0 RSF 1030 1133 920 1380 1656 1000 900
NXC 1180 6 A 2 L 0 RSF* 1180 1298 1030 1463 1755 1150 1000
NXC 1500 6 A 2 L 0 RSF 1500 1650 1300 1950 2340 1500 1300 AF14 4406 x 2275 x 605/3900
NXC 1900 6 A 2 L 0 RSF 1900 2090 1500 2250 2700 1800 1500
NXC 2250 6 A 2 L 0 RSF* 2250 2475 1900 2782 3335 2000 1800

*Max. ambient temperature of +35°C.
Hardware configurations

Active front- end Enclosure EMC Brake chopper Cabling Input device Output filters
380-500 V IP21 IP54 L T Bottom Top+CIT/+COT +ILS & +ICB +OCM/+OCH +ODU +OSI
AF9 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +600)
AF10 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +600)
AF12 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +1200)
AF13 S O (H: +170) S O * (W: +400) S O (W: +400) S O O O (W: +800)
AF14 S O (H: +170) S O * (W: +400) S O (W: +600) S O S O (W: +1600)
525-690 V
AF9 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +600)
AF10 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +600)
AF12 S O (H: +130) S O * (W: +400) S O (W: +400) S O O (W:+400) O (W: +1200)
AF13 S O (H: +170) S O * z(W: +400) S O (W: +400) S O O O (W: +800)
AF14 S O (H: +170) S O * (W: +400) S O (W: +600) S O S O (W: +1600)

S = Standard O = Optional *Contact factory

Technical data

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (20)Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (20)Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (45)Option boards

Type Description Card slot I / O signal
 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

E

DI DO DI DO AI (mA/V/±V) AI (mA) isolated AO (mA/V) AO (mA) isolated RO (NO/NC) RO (NO) +10Vref Therm +24V/ EXT +24 V pt100 KTY84 42-240 VAC input DI/DO (10…24 V) DI/DO (RS422) DI ~ 1Vp-p Resolver Out +5 V/+15 V/+24 V Out +15 V/+24 V Out +5 V/+12 V/+15 V
Basic I/O cards (OPTA)
OPTA1 DI/DO/AI/AO/ 10V/ 24V 6 1 2 1 1 2
OPTA2 Relay output (NO/NC) 2
OPTA3 Relay output + Thermistor input 1 1 1
OPTA4 Encoder TTL type 2 3/0 1
OPTA5 Encoder HTL type 2 3/0 1
OPTA7 Double encoder HTL type 6/2 1
OPTA8 “OPTA1 + Analogue signals galvanically isolated as a group” 6 1 2 1 1 2
OPTA9 OPTA1 + 2,5mm2 connectors 6 1 2 1 1 2
OPTAE Encoder HTL type (Divider + direction) 2 3/0 1
OPTAF STO, ATEX therm 2 1 1 1
OPTAK Sin/Cos encoder interface 3 1
OPTAN DI/AI/AO 6 2 2
I/O expander cards (OPTB)
OPTB1 Programmable I/O 6 1
OPTB2 Relay output + Thermistor input 1 1 1
OPTB4 “Analog input/output Analogue signals galvanically isolated separately” 1 2 1
OPTB5 Relay output 3
OPTB8 “Temperature Measurement option PT100” 1 3
OPTB9 DI + Relay output 2 1 5
OPTBH “Temperature Measurement option pt100, pt1000, Ni1000, KTY84” 3 3
OPTBB EnDat + Sin/Cos 1 Vp-p 2 0/2 2 1
OPTBC Resolver, 3xDO (Wide range) 3/3 1
OPTBE EnDat/SSI/BiSS C
OPTBL Advanced safety option 4 2 1
OPTBM OPTBL+ HTL/TTL encoder 4 2 1
OPTBN OPTBL+ Sin/Cos encoder 4 2 1
Fieldbus cards (OPTC and OPTE)*
OPTE2 RS485 with screw terminal RS485 with screw terminal
OPTE3 PROFIBUS DP with screw terminal PROFIBUS DP with screw terminal
OPTE5 PROFIBUS DP with D9-connector PROFIBUS DP with D9-connector
OPTE6 CANopen CANopen
OPTE7 DeviceNet DeviceNet
OPTE8 RS485 with D9-connector RS485 with D9-connector
OPTE9 Dual-port Ethernet Dual-port Ethernet
OPTEA Advanced Dual-port Ethernet Advanced Dual-port Ethernet
OPTC2 RS485 with screw terminal RS485 with screw terminal
OPTC3 PROFIBUS DP with screw terminal PROFIBUS DP with screw terminal
OPTC4 LonWorks LonWorks
OPTC5 PROFIBUS DP with D9-connector PROFIBUS DP with D9-connector
OPTC6 CANopen CANopen
OPTC7 DeviceNet DeviceNet
OPTC8 RS485 with D9-connector RS485 with D9-connector
OPTCI Modbus/TCP Modbus TCP
OPTCJ BACnet MS/TP BACnet MS/TP
OPTCP PROFINET IO PROFINET IO
OPTCQ EtherNet/IP EtherNet/IP
Communication cards (OPTD)
OPT-D1 SystemBus adapt, 2xfibre-optic System Bus adapter (2 x fiber optic pairs)
OPT-D2 SystemBus (1xfiber), isol. CAN System Bus adapter (1 x fiber optic pair) & CAN-bus adapter (galvanically decoupled)
OPT-D3 RS232 adapter (no galv.isol.) RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypad
OPT-D6 CAN-Bus (galv. decoupled) CAN-bus adapter (galvanically decoupled)
OPT-D7 Line voltage measurement Line voltage measurement

*) OPTE series fieldbus cards provide most recent features on market and they are recommended for new installation

  1. Analogue signals galvanically isolated as a group
  2.  Analogue signals galvanically isolated separately

VACON® NXC options

Control terminal options (T group)
+TIO Basic I/O wired to external single-tier terminals
+TID Basic I/O wired to external two-tier terminals

+ additional terminals

+TUP* Terminals for 230 VAC control voltage
Input device options (I group)
+ILS* Load switch
+IFD Switch fuse and fuses
+ICB* Circuit breaker
+ICO Input contactor
+IFU Input fuses
Main circuit options (M group)
+MDC Terminals in cabinet for DC / brake chopper
Output filter options (O group)
+OCM Common mode filters
+OCH Common mode filters with output terminals
+ODU du/dt filter
+OSI Sine wave filter
Protection devices (P group)
+PTR External thermistor relay
+PES Emergency stop (cat 0)
+PED Emergency stop (cat 1)
+PAP Arc protection
+PIF Insulation fault sensor
General options
+G40 400 mm empty cabinet
+G60 600 mm empty cabinet
+G80 800 mm empty cabinet
+GPL 100 mm base
+GPH 200 mm base
+FAT Factory acceptance tests
+MAR Marine construction
+SWP Seaworthy packing
Cabling options (C group)
+CIT Input (mains) cabling from top
+COT Output (motor) cabling from top
Auxiliary equipment (A group)
+AMF Motor fan control
+AMH Motor heater feeder
+AMB Mechanical brake control
+AMO* Motor operator for +ICB
+ACH Cabinet heater
+ACL Cabinet light
+ACR Control relay
+AAI Analogue signal isolator
+AAA Auxiliary contact (control voltage devices)
+AAC Auxiliary contact (input device)
+AT1 Auxiliary voltage transformer 200 VA
+AT2* Auxiliary voltage transformer 750 VA
+AT3 Auxiliary voltage transformer 2500 VA
+AT4 Auxiliary voltage transformer 4000 VA
+ADC* Power supply 24 VDC 2.5 A
+ACS 230 VAC customer socket
Door-mounted options (D group)
+DLV Pilot light (Control voltage on)
+DLD Pilot light (DO1)
+DLF Pilot light (FLT)
+DLR Pilot light (RUN)
+DCO* Main contactor operation switch
+DRO* Local / Remote operation switch
+DEP Emergency stop push-button
+DRP Reset push-button
+DAM Analogue meter (AO1)
+DAR Potentiometer for reference
+DCM Analogue meter & current transformer
+DVM Analogue voltage meter with selection switch

 

EMC selection table

 

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (45)

The product family standard
EN 61800-3 sets limits for both emissions and immunity to radio frequency disturbances. The environment has been divided into the first and second environments; in practice, public and industrial networks, respectively. Radio Frequency Interference (RFI) filters are typically required to meet the EN 61800-3 standard. These filters are integrated in the VACON® NXP as standard. The 208-240 V and 380 500 V ranges of the VACON® NXP (FR4-FR9) meet the requirements of the first and second environments (H level: EN 61800-3 (2004), category C2). No additional RFI filters or cabinets are required. The FR10-FR14 and the 500-690 V ranges of the VACON® NXP meet the requirements of the second environment (L-level: EN 61800-3(2004), category C3). The units in the frame sizes FR4, FR5 and FR6 (with a voltage range from 380 to 500 V) are also available with extremely low-emission integrated EMC filters (C level: EN 61800-3 (2004), category C1). This is sometimes required in very sensitive locations, such as hospitals.

Type code key

NXC 0520 5 A 2 L O S S F A1 A2 00 00 00 + IFD

  • NXC Product Range
  • NXP = Wall-mounted / standalone / module
  • NXC = Cabinet
  • 0520 Nominal current voltage
  • 0520 = 520 A
  • 5 Nominal mains voltage
  • 2 = 208-240 V
  • 5 = 380-500 V
  • 6 = 525-690 V
  • A Control keypad
  • A = Standard alphanumeric
  • B = No local keypad
  • F = Dummy keypad
  • G = Graphic display
  • 2 Enclosure class
  • 5 = IP54, FR4-10; NXC FR9-FR14; AF9-14
  • 2 = IP21, FR4-11; NXC FR9-FR14; AF9-14
  • 0 = IP00, NXP FR10-14
  • L EMC emission levels
  • C = Category C1, EN 61800-3
  • H = Category C2, EN 61800-3
  • L = Category C3, EN 61800-3
  • T = For IT networks
  • N = Enclosure required (FR10-FR14) 0 Brake chopper 0 = No brake chopper 1 = Integrated brake chopper S Supply S = 6-pulse
  • T = 12-pulse
    O = 6-pulse + load switch (standalone)
  • R = Low Harmonic S Cooling
  • S = standard air-cooled
  • T = through-hole mounting FR4-FR9
  • F Control
  • S = Standard FR4-FR8
  • F = Standard FR9 and NXC
  • A = Standard NXP FR10-FR12
  • N = Standard IP00 FR10 & NXC with IP54 control unit enclosure
  • V = As S, but varnished
  • G = As F, but varnished boards
  • O = As N, but varnished boards
  • B = As A, but varnished boards
  • A1 Option boards; each slot is represented by two characters:
  • Ax = Basic I/O boards,
  • Bx = Expander I/O boards
  • Cx = Fieldbus boards,
  • Dx = Special boards A2 00 00 00 + IFD NXC options, see tables page 22

DrivePro® Life Cycle services
Delivering a customized service experience! We understand that every application is different. Having the ability to build a customized service package to suit your specific needs is essential. DrivePro® Life Cycle Services is a collection of tailormade products designed around you. Each one engineered to support your business through the different stages of your AC drive’s life cycle. From optimized spare-part packages to condition-monitoring solutions, our products can be customized to help you achieve your business goals. With the help of these products, we add value to your application by ensuring you get the most out of your AC drive. When you deal with us, we also offer you access to training, as well as the application knowledge to help you in planning and preparation. Our experts are at your service.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (32)

You’re covered
with DrivePro® Life Cycle service products

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (33)DrivePro® Retrofit
Minimize the impact and
maximize the benefit
Manage the end of product lifecycle efficiently, with professional help to replace your legacy drives.
The DrivePro® Retrofit service ensures optimal uptime and productivity during the smooth replacement process.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (33)DrivePro® Spare Parts
Plan ahead with your spare part package
In critical situations, you want no delays. With DrivePro® Spare Parts you always have the right parts on hand, on time. Keep
your drives running at top efficiency, and optimize system performance.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (35)DrivePro® Extended Warranty
Long-term peace of mind
Get the longest coverage available in the industry, for peace of mind, a strong business case and a stable, reliable budget. You know the annual cost of maintaining your drives, up to six years in advance.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (36)DrivePro® Exchange
The fast, most cost-efficient alternative to repair
You obtain the fastest, most cost-efficient alternative to repair, when time is critical. You increase uptime, thanks to quick and correct replacement of the drive.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (37)DrivePro® Upgrade
Maximize your AC drive investment
Use an expert to replace parts or software in a running unit, so your drive is always up-to-date. You receive an on-site evaluation, an upgrade plan and recommendations for future improvements.

Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (38)DrivePro® Start-up
Fine-tune your drive for optimal performance today
Save on installation and commissioning time and cost. Get help from professional drives experts during start-up, to optimize drives safety, availability and performance.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (39)DrivePro® Preventive Maintenance
Take preventive action
You receive a maintenance plan and budget, based on an audit of the installation. Then our experts perform the maintenance tasks for you, according to the defined plan.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (40)DrivePro® Remote Expert Support
You can rely on us every step of the way
DrivePro® Remote Expert Support offers speedy resolution of on-site issues thanks to timely access to accurate information. With the secure connection, our drives experts analyze issues remotely reducing the time and cost involved in unnecessary service visits.
Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (41)DrivePro® Remote Monitoring
Fast resolution of issues DrivePro® Remote Monitoring offers you a system that provides online information available for monitoring in real time. It collects all the relevant data and analyzes it so that you can resolve issues before they affect your processes.

To learn which products are available in your region, please reach out to your local Danfoss Drives sales office or visit our website http://drives.danfoss.com/danfoss-drives/local-contacts/

 

Stay calm. You’re covered.Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (42)

Stay calm. You’re covered.
Use the DrivePro® app for fast access to the DrivePro® services, for improved productivity, performance and uptime of your systems. Find your closest service partner, place a service request, and register your AC drives. You can also look up product information, specifications and manuals for your specific drive.

Quick, simple, reliable. Giving you complete control. Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (43) Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (44)

Follow us and learn more about AC drives Danfoss-VACON-NXP-and-VACON-NXC-AC-Drives- (45)

Danfoss Drives
Danfoss Drives is a world leader in variable speed control of electric motors. We aim to prove to you that a better tomorrow is driven by drives. It is as simple and as ambitious as that.

We offer you unparalleled competitive edge through quality, application-optimized products targeting your needs – and a comprehensive range of product lifecycle services. You can rely on us to share your goals. Striving for the best possible performance in your applications is our focus. We achieve this by providing the innovative products and application know-how required to optimize efficiency, enhance usability, and reduce complexity.
From supplying individual drive components to planning and delivering complete drive systems; our experts are ready to support
you all the way.

We draw on decades of experience within industries that include:

  • Chemical
  • Cranes and Hoists
  • Food and Beverage
  • HVAC
  • Lifts and Escalators
  • Marine and Offshore
  • Material Handling
  • Mining and Minerals
  • Oil and Gas
  • Packaging
  • Pulp and Paper
  • Refrigeration
  • Water and Wastewater
  • Wind

You will find it easy to do business with us. Online, and locally in more than 50 countries, our experts are never far away, reacting fast when you need them. Since 1968, we have been pioneers
in the drives business. In 2014, Vacon and Danfoss merged, forming one of the largest companies in the industry. Our AC drives can adapt to any motor technology and we supply products in a power range from 0.18 kW to 5.3 MW.

Frequently Asked Questions

  • Q: What industries can benefit from this product?
    A: This product is ideal for industries such as mining, compressors, marine, cranes, metals, chemical, water treatment, oil & gas, pulp & paper, cement, and general process industries.
  • Q: How can I access support for this product?
    A: Danfoss Drives provides global service solutions available 24/7 to assist original equipment manufacturers (OEMs), system integrators, distributors, and end users throughout the product lifecycle.