Specifications

Type Parameters Values
Operating range 90% reflectivity, 0Klux 0.1m~40m
10% reflectivity, 0Klux 0.1m~13.5m
90% reflectivity, 100Klux 0.1m~40m
10% reflectivity, 100Klux 0.1m~13.5m

Product Overview
TF02-i is a single-point ranging LiDAR upgraded based on TF02-Pro. It has been optimized and upgraded in terms of communication interface, input voltage, etc., to meet the needs of various industrial scenarios. The product is based on the principle of ToF (time of flight) and has stable, accurate, and highly sensitive measurement performance.

Technical Specifications
TF02-i offers accurate distance measurement with a resolution of 1cm. It operates within a range of 0.1m to 40m for 90% reflectivity and 0Klux lighting conditions. Maintenance and Cleaning

  • Before switching on, check if the exposed window mirror is clean; clean it promptly if dirty.
  • After use, check the optics for contamination and clean if necessary.
  • Clean the optics regularly if operating in a severe environment for an extended period.
  • Disconnect power before cleaning. Gently wipe the window with a soft cloth in one direction when the device is not operating to avoid damage.

PREFACE
Dear users:
Thank you for choosing Benewake products. For the purpose of offering better operation experience to you, we hereby write this manual for an easier and simpler operation of our product, hoping to better solve the common problems you may meet. This user manual contains the relevant information on product introduction, usage and maintenance of TF02-i, covers the product operation introduction and common problem solutions. Please read this manual carefully before using the product. Remember the precautions to avoid hazards, and please follow the described steps in the manual when using it.
If you have any problems in the process of usage, you are welcome to contact Benewake at any time for help.

Contact Details

  • Official website: en.benewake.com
  • TEL:+86-10-57456983
  • Technical questions,please contact:support@benewake.com
  • Consult sale information or request brochure,please contact:bw@benewake.com
  • Headquarters Address
    Benewake (Beijing) Co., Ltd. 3rd Floor, Haiguo Jiaye Sci-Tech Park, Haidian District, Beijing, China

Copyright Statement This User Manual is copyright © of Benewake. Please do not modify, delete or translate the description of this manual contents without the official written permission from Benewake.

Disclaimer
As our products are constantly improving and updating, the specifications of TF02-i are subject to change. Please refer to the official website for latest version.

OVERVIEW

TF02-i is a single-point ranging LiDAR upgraded based on TF02-Pro. It has been
optimized and upgraded in terms of communication interface, input voltage, etc., to
meet the needs of various industrial scenarios. The product is based on the principle of
ToF (time of flight) and has stable, accurate and highly sensitive measurement
performance.

Technical Specification
Table 1- 1 Technical Specification of TF02-i

Type Parameters Values
 

 

 

 

Product performance

 

Operating range

90% reflectivity, 0Klux 0.1m~40m
10% reflectivity, 0Klux 0.1m~13.5m
90% reflectivity, 100Klux 0.1m~40m
10% reflectivity, 100Klux 0.1m~13.5m
Accuracy ±5cm(0.1m~5m),±1%(5m~40m)
Distance resolution 1cm
Frame rate 1Hz~100Hz(adjustable, default100Hz)
Repeatability 1σ:  <2cm(0.1m~35m@90% reflectivity)
Ambient light immunity 100Klux
Enclosure rating IP65
 

Optical parameters

Photobiological safety Class1 (IEC60825)
Central wavelength 850nm
Light source VCSEL
FoV
 

Electrical parameters

Supply voltage DC 7V~30V
Average current ≤70mA @12V
Power consumption ≤0.85W @12V
Peak current 100mA
 

 

 

Others

Dimension 69mm×41.5mm×31.5mm  (L×H×W)
Housing ABS/PC/PMMA
Operating temperature -20℃~60℃
Storage temperature -30℃~80℃
Weight 60g (with cables)
Cable length 70cm

Note

  1. The detection is measured with the standard white board (90% reflectivity).
  2. The frame rate can be adjusted. The default value is 100Hz and the maximum value is 100Hz, the customized frame rate should be calculated by the formula: 200/n (n is an integer with ≥ 2).
  3. The angle is a theoretical value, the actual angle value has some deviation.

Maintenance and Cleaning

  • Before switching on, please check if the exposed window mirror is clean, and clean it promptly if it is dirty.
  • After using the device, check the optics. If it is contaminated, please clean it promptly.
  • The optics should be cleaned regularly if the device be operated in a severe environment for a long time.
  • Before regular cleaning, please disconnect the power. Using a soft cloth to gently wipe the window in the same direction when the device is not operating, to avoid repeated wiping and damage to the window mirror.
  • When cleaning the window, do not use alcohol to clean, so as not to damage the window.
  • If you require deep cleaning of internal optics, please contact bw@benewake.com to offer professional advice.

Appearance and Structure
The appearance and dimensions of TF02-i are shown in Figure 1- 1 and Figure 1- 2:

Benewake-TF02-i-Distance-Sensors-FIG- (1)Benewake-TF02-i-Distance-Sensors-FIG- (2)

TF02-i is recommended to use M2.5 round Phillips screws for installation. Please remove the protective film of the optical lens before use. The lens of front panel of LiDAR cannot be covered. Please keep it clean. The surface of optical lens is the rangingzero of LiDAR. The detection angle of TF02-i is 3°. At different distances, the size of light spot, namely the edge length of the detection range, is different. Side length of the detection range at different distances (the detection range is a square), as shown in Table 1- 2.

Table 1- 2 Spot Size at Different Distances

Distance(m) 1 2 3 5 7 10 20 30 40
Spot size(cm) 5 10 16 26 37 52 105 156 208

Note: The side length of target object generally should be larger than size of the TF02-i light spot; if the side length of the detected object is smaller than size of light spot, the output (Distance) from TF02-i will be a value between the actual distance values of the two objects.

Storage

  • Device should be stored at -30°C to 80°C with a relative humidity ≤ 60% and ventilation free from corrosive gases.
  • Before storage, please make sure that all connections are disconnected or dust covers are inserted or covered to ensure cleanliness.
  • If storage time is over three months, please carry out a working test before using, to ensure that the device can be used in normal condition.
  • For ensuring the product performance, do not open the product shell or remove the IR-pass filter.

Application
When using the product, please read the specifications, user manual and the precautions mentioned in the user manual in detail to ensure that the product is used within the rated specifications. The product is designed for use in the following scenarios:

  • Robot
  • Intelligent Transportation
  • Intelligent Device
  • UAV
  • Other Industrial Products

If you use the product beyond the above application scope, please carefully evaluate whether the reliability requirements of the product to be applied match this product, or contact Benewake at any time to assist in solving it.

INTERFACE

Description Of Wiring Sequence
Terminal model: MH1.25-7P-W/B, size of single wire is AWG26, diameter of single wire is 0.404mm, cross-sectional area is 0.129mm2, which show in Table 2- 1.

Benewake-TF02-i-Distance-Sensors-FIG- (3)

Table 2- 1 The Function Description of Each Wire

Pin Wiring color Function Comment
1 Red VCC Power supply
2 White/Yellow RS485-B/CAN_L RS485-B/CAN bus
3 Green RS485-A/CAN_H RS485-A/CAN bus
4 N/A N/A N/A
5 Blue/Orange UART_RXD UART receive (Debug)
6 Brown UART_TXD UART transmit (Debug)
7 Black GND Ground

Warning

  1. The hardware of RS-485 and CAN is different; Do not mix UART cable with RS485 or CAN bus, otherwise it will cause damage of MCU.
  2. TF02-i with RS-485 interface does not support UART debugging pins.

Electrical Characteristics
Table 2- 2 Main Electrical Parameters of TF02-i

Parameter Values
Supply voltage DC 7V~30V
Average current ≤70mA@12V
Peak current 100mA
Average power consumption ≤0.85W@12V

COMMUNICATION PROTOCOL

There are two communication interfaces available. The hardware of RS485 and CAN is different. The interface can not be switched by command.

RS-485 Communication Protocol

Communication protocol
Modbus protocol is the default setting for RS-485 interface. The parameter is shown in Table 3- 1. The default value of baud rate and slave ID is 115200 and 0x01.

Table 3- 1 RS-485 Communication protocol of TF02-i

Characteristics Values
Communication interface RS-485
Baud rate 115200
Data bit 8
Stop bit 1
Parity None

Note
The following baud rates are supported: 9600,14400,19200,38400,43000, 57600 , 768000 , 115200(default) , 128000 , 230400 , 256000. It is not recommended to use a baud rate above 115200 for communication because of communication stability.

Parameter configuration description of Modbus protocol
Description of data frame
When Modbus protocol of TF02-i is enabled, the Modbus command format of reading distance is shown in Table 3- 2.

Table 3- 2 The command format of reading distance

Addr. Function code Register Addr. Register Value CRC_Low CRC_High
01(Default) 03 00 00 00 01 xx xx

The response data frame format is shown in Table 3- 3.

Table 3- 3 The response date frame format

Addr. Function code Length Dist_High Dist_Low CRC_Low CRC_High
01(Default) 03 02 XX XX xx xx

Function code
The function code of TF02-I is shown in Table 3- 4.

Table 3- 4 The function code

Function Code Description
03 Read register
06 Write register

Register address list

  • All register addresses are hexadecimal and register values are 16 bits;
  • After setting parameter, save and restart to take effect.

Register address list using function code: 0x03(read only)

Table 3- 5 Register address of function code (0x03)

Register

Addr.

Definition Description
00 00 Dist Distance value, unit: cm
00 01 Strength Signal strength
00 03 High 16 bits of timestamp High 2 bytes of time stamp, unit: ms
00 04 Low 16 bits of timestamp Low 2 bytes of time stamp, unit: ms
00 06 High 16 bits of firmware

version

0x00 and main version number
00 07 Low 16 bits of firmware version Sub-version  and  revised  version

number

Register address list using function code: 0x06(write only): Table 3- 6 Register address of function code (0x06)

Register Addr. Definition Description
00 80 Save setting Write any value to save settings
 

00 81

 

Power off/Reboot

Register value:

0x00:   power    off   (Not   currently supported)

0x01: reboot

00 82 Disable Modbus Register Value:

0x01: Disable Modbus

00 83 High

rate

16 bits of baud Set baud rate, save and reboot to take

effect

00 84 Low 16 bits of baud rate Set baud rate, save and reboot to take

effect

00 85 Slave ID Set slave ID, save and reboot to take

effect (default 0x01)

00 86 Frame rate Set frame rate, save and reboot to take

effect (default 100Hz)

 

 

00 87

 

 

Working mode

Set working mode, save and reboot to take effect. Register value:

0x00:   continuous   detection   mode (default)

0x01: triggering mode

 

 

00 88

 

Low             power

consumption mode

Set low power consumption mode, save and reboot to take effect. Register value: 0x00: Disable (default)

0x0N: Enable, N is a positive integer with

≤10,which is sampling frequent of TF02-i

00 89 Restore default Write any value, save and reboot to take

effect

Parameter configuration
Table 3- 7 General command of RS-485 serial communication mode

Function Command Respnse Description
Enable

Modbus

5A 05 15 01 75 5A 05 15 01

75

Save and reboot to take effect
Strength threshold and distance under threshold  

 

5A 07 22 XX LL HH SU

 

 

5A 07 22 XX LL HH SU

The default setting is:

When strength is below 60, make distance output 4500cm: XX=60/10=6(DEC)=06(HEX) 4500(DEC)=1194(HEX)

LL=94,HH=11

Save setting 5A 04 11 6F 5A 05 11 00

70

 

Table 3- 8 General command of Modbus protocol

Function Command Response Description
          DH: High 8 bits of distance
Read 01 03 00 00 00 01 03 02 DH DL: Low 8 bits of distance
distance 01 84 0A     DL CL CH CH: High 8 bits of CRC
          CL: Low 8 bits of CRC
Read distance and signal

strength

 

01 03 00 00 00

02 C4 0B

01 03 04 DH DL SH SL CL CH  

SH: High 8 bits of signal strength SL: Low 8 bits of signal strength

Read firmware

version

01 03 00

02 24 0A

06 00 01 03 04 00

VM VS VC CL CH

VM: Main version number VS: Sub-version number

VC: Revised version number

      BH1: High 8 bits of baud rate
      BH2: Secondary high 8 bits of
 

 

Set baud rate

01 06 00 83 BH1 BH2 CL CH

01 06 00 84 BL1 BL2 CL CH

01 06 00 83

BH1 BH2 CL CH

01 06 00 84

BL1 BL2 CL CH

baud rate

BL1: Secondary low 8 bits of baud rate

BL2: Low 8 bits of baud rate For example:

Set   baud    rate   to   9600

(0x00002580):

      BH1=00 BH2=00 CL=78 CH=22,
      BL1=25 BL2=80 CL=D2 CH=D3
 

Modify ID

 

slave

 

01 06 00 85 IH IL CL CH

 

01 06 00 85 IH IL CL CH

IH: High 8 bits of slave ID IL: Low 8 bits of slave ID For example:

Modify slave ID to 0x0002:

IH=00 IL=02 CL=19 CH=E2

 

Modify frame rate

 

01 06 00 86 FH FL CL CH

 

01 06 00 86

FH FL CL CH

FH: High 8 bits of frame rate FL: Low 8 bits of frame rate For example:

Modify   frame    rate  to (0x0064):

FH=00 FL=64 CL=69 CH=C8

 

 

100

 

 

Low power consumption mode

 

 

01 06 00 88 LH LL CL CH

 

 

01 06 00 88

LH LL CL CH

LH: High 8 bits of sampling frequent in low power consumption mode

LL: Low 8 bits of sampling frequent in low power consumption mode

For example:

Set it to 5Hz low power consumption mode,

      LH=00 LL=05 CL=C9 CH=E3
Save setting 01 06 00 80 00 01 06 00 80 00 Save and reboot to take effect
  00 88 22 00 88 22  
Disable

Modbus

01 06 00 82 00

01 E8 22

01 06 00 82 00

01 E8 22

Save and reboot to take effect
Restore

default

01 06 00 89 00

00 58 20

01 06 00 89 00

00 58 20

 

Warning
RTU mode is only supported for communication in serial communication.

For example:

  1. Enable Modbus protocol in RS-485 serial communication mode:
    • 5A 05 15 01 75 //Enable Modbus protocol
    • 5A 04 11 6F //Save settings
      Enter Modbus protocol mode after rebooting.
  2. Disable Modbus protocol:
    • 01 06 00 82 00 01 E8 22 //Default address is 0x01, disable Modbus protocol
    • 01 06 00 80 00 00 88 22 //Default address is 0x01, save setting
      Exit Modbus protocol after rebooting.

Warning

  1. 0 is the broadcast ID, the transmitting and receiving ID cannot be set to 0.
  2. The following baud rates are supported: 1000kbps,900 kbps,800 kbps, 666 kbps,500 kbps,400 kbps,250 kbps,200 kbps,160 kbps,125 kbps,

CAN Communication Protocol
Communication Protocol
The CAN communication protocol of TF02-i supports customer-defined protocol parameters or customized services, and the CAN protocol baud rate and ID can be modified. The CAN protocol is shown in Table 3- 9.

Table 3- 9 CAN communication protocol of TF02-

   
Communication interface CAN
Baud rate 250kbps
Transmitting ID 0x00000003
Receiving ID 0x00000003
Frame format Standard frame

Warning

  1. 0 is the broadcast ID, the transmitting and receiving ID cannot be set to 0.
  2. The following baud rates are supported: 1000kbps,900 kbps,800 kbps, 666 kbps,500 kbps,400 kbps,250 kbps,200 kbps,160 kbps,125 kbps,100 kbps.

CAN Communication Data Frame
The data protocol of CAN is shown in Table 3- 10. Each data frame consists of 8 bytes and the data contains the distance (unit: cm), signal strength and timestamp (unit: ms).

Table 3- 10 The date frame format of CAN communication

Data byte Definition Description
Byte0 Dist_L Low 8 bits of distance
Byte1 Dist_H High 8 bits of distance
Byte2 Strength_L Low 8 bits of signal strength
Byte3 Strength_H High 8 bits of signal strength
Byte4 Timestamp Low 8 bits of timestamp
Byte5 Timestamp Secondary low 8 bits of timestamp
Byte6 Timestamp Secondary high 8 bits of timestamp
Byte7 Timestamp High 8 bits of timestamp

CAN Bus Network
The CAN bus network is mainly hung in CAN_H and CAN_L, and each node performs serial differential transmission of signals through two lines. In order to avoid signal reflection and interference, it is recommended to connect 120Ω end point resistors at both ends of the bus, as shown in Figure 3- 1.

Benewake-TF02-i-Distance-Sensors-FIG- (4)

Note
It is recommended to contact Benewake to communicate the details of use to complete networking requirements.

Parameter Configuration of CAN Communication
The configuration command format of CAN communication is shown as below.

Table 3- 11 The configuration command format

Byte 0 1 2 3 4 5-8 9-12 13
Description Header Length ID Type Baudrate Recv_id Trans_id Check_sum
Default 0x5A 0x0E 0x51 0 0x08 0x00000003 0x00000003 SU
  • Type: 0(Standard Frame), 1(Extended Frame);
  • Recv_id: TF02-i receiving ID, Little Endian;
  • Send_id: TF02-i transmitting ID, Little Endian.
  • Baudrate: The code of baud rate, default 250kbps, corresponding to 0x08. The relation between baud rate(unit: kbps) and Byte4 is shown as below:

Table 3- 12 The byte4 value corresponds to the baud rate

Byte4 value 0 1 2 3 5
Baud rate (unit: kbps) 1000 900 800 666 500
Byte4 value 8 10 11 14 16
Baud rate (unit: kbps) 250 200 160 125 100

Example of configuration:

  • Example1: Standard frame, Baud rate 500kbps, receiving ID=0x00000010, transmitting ID=0x00000020
  • Command: 5A 0E 51 00 05 10 00 00 00 20 00 00 00 EE
  • Example2: Extended Frame, Baud rate 250kbps, receiving ID=0x0000AABB, transmitting ID=0x0000CCDD
  • Command: 5A 0E 51 01 08 BB AA 00 00 DD CC 00 00 D0

Other Parameter Configuration
Table 3- 13 General parameter configuration of TF02-i

Function Command Response Description
Read firmware

version

5A 04 01 5F 5A 07 01 V1 V2

V3 SU

Version V3.V2.V1
 

Frame rate

5A 06 03 LL HH SU 5A 06 03 LL HH SU 1-100Hz, default 100Hz

LL: Low 8 bits of frame rate HH: High 8 bits of frame rate

Trigger

detection

5A 04 04 62 Data frame Set frame rate to 0, detection can

be triggered with this command

System reset 5A 04 02 60 5A 05 02 00 61 Succeeded
5A 05 02 01 62 Failed
Disable/Enable

output

5A 05 07 00 66 5A 05 07 00 66 Disable data output
5A 05 07 01 67 5A 05 07 01 67 Enable data output
 

Strength threshold and distance under threshold

 

 

5A 07 22 XX LL HH SU

 

 

5A 07 22 XX LL HH SU

The default setting is:

When strength is below 60, make distance output 4500cm: XX=60/10=6(DEC)=06(HEX) 4500(DEC)=1194(HEX)

LL=94,HH=11

Restore to

factory settings

5A 04 10 6E 5A 05 10 00 6F Succeeded
5A 05 10 01 70 Failed
Save setting 5A 04 11 6F 5A 05 11 00 70 Succeeded
5A 05 11 01 71 Failed
Enable/Disable

120Ω terminal resistor

5A 05 60 01 C0 5A 05 60 01 C0 Enable 120Ω terminal resistor
5A 05 60 00 BF 5A 05 60 00 BF Disable 120Ω terminal resistor

Warning

  1. The customized frame rate should be calculated by the formula: 200/n (n is an integer with ≥ 2).
  2. SU is checksum, checksum is disable by default.
  3. Please keep power on and wait 1s after sending system reset command, otherwise the settings will not take effect.
  4. After parameters configuration, send saving settings command to save the configuration, otherwise the settings will not take effect.
  5. 120Ω terminal resistor is disable in default.

©2024 Benewake (Beijing) Co., Ltd. · All rights reserved · REV: 01/04/2024

FAQ

Q: Can the frame rate be adjusted on TF02-i?
A: Yes, the frame rate can be adjusted within a range of 1Hz to 100Hz, with the default value set at 100Hz.

Q: What is the power supply voltage range for TF02-i?
A: TF02-i operates within a supply voltage range of DC 7V to 30V.