Unpacking and install

Take the D70ES terminal, quick start guide, sealing screws, and sense shorting plug out of the packaging.

Wiring of analog load cells and serial ports

B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-1

Diagram shows terminal strip wiring to connect the scale, 4 wires (local sense) install the jumper plug wires oriented over the Ex & SEN (the plug will have the two open positions on the left) 6 wires (Remote Sense) remove the jumper, as well as com ports wiring.

Turn the indicator on using the power button

If D70ES asks for a time and date you can key this in and press enter to accept.

To enter parameters

Press the calibration button in the upper right corner of the main boardB-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-2

or hold Enter KeyB-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-3 while turning on the indicator until “SETUP” appears. (This will not let you modify scale configuration)

Key functions while in parameters
Function Key Operation
 2 FN / ESC B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-4 Parameter down for header and sub-parameter selections
 Print B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-5  Up for header and sub-parameter selections
 Enter B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-6  Enter and advance to the next sub parameter
 Keyed Tare B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-7  Display values while in sub-parameters
 Auto Tare B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-8  Exit or back out of sub-parameters

Menu Structure

B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-21

Span Calibration

Step Display Press key Description
 0 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-16 Press “Cal” Button to enter setup mode
 1 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-9 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-17  Start calibration procedure
 

2

B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-10 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-18  Select zero sampling
3 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-11 For a second, then-current weight on display the 0
B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-12 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-6 Sample dead load; wait for stability before pressing key
 4 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-13 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-19 Press Tare to enter span weight sampling
5 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-14   For a second, then sampling weight on display
B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-12 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-6 Enter a new SPAN weight value using the numeric keypad.
 6 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-15 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-6 Load the scale and press enter to except the value
 7 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-12 B-TEK-D70ES-Multi-Functional-Analog-Indicator-fig-17 Press FN key or “Cal” button to save the calibration

B-TEK Scales, LLC
800.266.8900 Fax: 330.471.8909 Monday – Friday 7:00 AM – 5:00 PM www.B-TEK.com sales@b-tek.com.

Documents / Resources

B-TEK D70ES Multi-Functional Analog Indicator [pdf] User Guide
D70ES Multi-Functional Analog Indicator, D70ES, Multi-Functional Analog Indicator, Analog Indicator, Indicator
B-TEK D70ES Multi Functional Analog Indicator [pdf] User Guide
D70ES Multi Functional Analog Indicator, D70ES, Multi Functional Analog Indicator, Functional Analog Indicator, Analog Indicator, Indicator

References

Leave a comment

Your email address will not be published. Required fields are marked *