AKO D14120 Temperature Controller

AKO-D14120-Temperature-Co-PRODUCT

Specifications:
  • Model Numbers: AKO-D14120, AKO-D14123, AKO-D14012, AKO-D14023, AKO-D14023-C, AKO-D14024, AKO-D14124, AKO-D14125
  • Input Voltage: 230 V~ 50/60 Hz (AKO-D14123, AKO-D14124, AKO-D14125), 120 V~ 50/60 Hz (AKO-D14120), 5203/600VH~z (AKO-D14023, AKO-D14024)
  • Max Current: 16 A LN
  • Modes: Heat (P0=1), Cold (P0=0)
  • Probe Length: 29mm
  • Dimensions: 71mm x 123456

Product Usage Instructions

Warnings:
Ensure the probe and its cable are not installed in the same conduit as power, control, or supply cables.

 Installation:
Refer to the installation instructions provided in the manual for your specific model number.

Wiring:
Do not install the probe and its cable in the same conduit as power, control, or supply cables to prevent interference.

Operation:
Use the key equipment to access program mode and set the display to the desired settings for heating or cooling.

Start-up:
For 3-key models, on power-up, the equipment will start in Wizard mode. Select the appropriate application using N or Q and press SET to configure parameters.

Access to set point and programming:
Press the SET key for 5 seconds to modify the set point (SP) and for 10 seconds to access the programming menu. Use the Up and Down keys to navigate through levels and parameters.

 Setting parameters:
In the Programming Menu, changes will not be saved if there is no key input for 20 seconds. Use the SET key to navigate through different levels and parameters to set values accordingly.

FAQ:

  • Q: What should I do if the equipment does not start in Wizard mode during startup?
    A: Ensure that the power supply is connected properly and try restarting the equipment. If the issue persists, refer to the troubleshooting section in the manual.
  • Q: Can I install multiple probes with this equipment?
    A: The manual does not specify support for multiple probes. It is recommended to use one probe per equipment based on the model number.

Warnings

  • Using the equipment without following the manufacturer’s instructions may affect the device’s safety requirements. To ensure that the device operates correctly, only probes supplied by AKO should be used.
  • The unit must be installed in a location protected from vibrations, water and corrosive gases, where the ambient temperature does not exceed that shown in the technical data.
  • To ensure a correct reading, the probe must be situated in a location without any external heat influences except for the temperature which is being measured or controlled.
  • The power supply circuit must be provided with a main switch rated at at least 2 A, 230 V, located close to the equipment.
  • The cables will enter through the back and should be type H05VV-F or H05V-K. The gauge will depend on local regulations, but should in no case 2 be less than 1 mm .
  • Connecting wires for the relay contacts should be sized 2.5 mm . -Between -40 ºC and +20 ºC, if the probe NTC is prolonged till 1.000  m with a mínimum of cable 0,5 mm², the maximum deviation will be of 0,25 ºC (extension cable for probe ref. AKO-15586)

NOTE: Equipment not compatible with AKO-14917 (external communication module) and AKO-14918 (programming key).

 Installation

AKO-D14120-Temperature-Co- (2)

Wiring
The probe and its cable should NEVER be installed in the same conduit as power, control or supply cables.

AKO-D14123, AKO-D14124, AKO-D14125

AKO-D14120-Temperature-Co- (3)

Operation

key equipment

AKO-D14120-Temperature-Co- (4)

SET key

  • Press for 5 seconds to modify the set point (SP).
  • Press for 10 seconds to go to the programming menu.
  • In the programming menu, go to the level displayed or accept the new value while setting a parameter.

Up key AKO-D14120-Temperature-Co- (5)

  • Pressing for 5 seconds starts/stops defrosting.
  • In programming menu, allows you to scroll through the various levels or, during the setting of a parameter, to change the value.

Down key AKO-D14120-Temperature-Co- (6)

  • Pressing for 5 seconds activates Standby mode, pressing for 2 seconds returns the equipment to normal mode. In Standby mode, the equipment performs no actions and only the m indicator is displayed on the screen.
  • In programming menu, allows you to scroll through the various levels or, during the setting of a parameter, to change the value.

key equipmentAKO-D14120-Temperature-Co- (7)

SET key / AKO-D14120-Temperature-Co- (8)

  • Pressing for 5 seconds activates Standby mode, pressing for 2 seconds returns the equipment to normal mode. In Standby mode, the equipment performs no actions and only the m indicator is displayed on the screen.
  • Pressing for 10 seconds goes to the programming menu.
  • Pressing for 5 seconds in the programming menu goes to the level displayed on the screen or, during the setting of a parameter, accepts the new value.
  • In the programming menu, a short press allows you to scroll through the various levels or, during the setting of a parameter, to increment the value. When upper limit is reached, it will start again from the lower limit.

 Start-up

(Only 3 key models)
On power-up, the equipment will start up in Wizard mode (P3 / 1 flashing), press AKO-D14120-Temperature-Co- (9) to select the most appropriate application and press SET.

  1. Multipurpose
  2. Frozen
  3. Fruits and vegetables
  4. Fresh fish
  5. Soft Drinks
  6. Bottle racks
  7. AC
  8. Heat / Incubators

The wizard will configure the parameters of the equipment for the chosen application (see table “Default settings by application”).

 Access to set point and programming

AKO-D14120-Temperature-Co- (10)

Setting parameters

Programming Menu (parameters)
After 20 seconds with no key being pressed, the equipment will return to the previous level. If you are on level 3, the changes will not be saved

AKO-D14120-Temperature-Co- (11)

Table of parameters and messages

Def. column shows factory-set default parameters. Those marked with * are variable parameters depending on the application chosen in the wizard or the P3 parameter (see table “Default parameters by application”). Unless otherwise stated, temperatures are expressed in °C. (Equivalent velues in °F)

AKO-D14023-C
AKO-D14012, AKO-D14023, AKO-D14024
AKO-D14120, AKO-D14123, AKO-D14124, AKO-D14125
Level1        Menus and description
rE Level 2          Control
Level 3        Description                                   Values Min. Def. Max.
99
SP Temperature Adjustment (Set Point)                                               With NTC (ºC/ºF)

(limits depending on probe type)                                                    With PTC

-50 (-58ºF) (210ºF)
150 (302ºF)
C0 Calibrating probe 1 (Offset)                                                                        (ºC/ºF) -20.0 0.0 20.0
C1 Probe 1 differential (Histeresis)                                                                    (ºC/ºF) 0.1 2.0 20.0
99 99
C2 Upper blocking of the set point                                                    With NTC (ºC/ºF)

(cannot be set above this value)                                                     With PTC

C3 (210ºF) (210ºF)
150 (302ºF)
C3 Lower blocking of the set point (cannot be set below this value)                             (ºC/ºF) -50 -50 C2
(-58ºF) (-58ºF)
 

C4

Type of delay for protection of the compressor:
0=OFF/ON (since the last disconnection); 1=ON (since start-up/reset);

2=OFF-ON/ON-OFF (since the last shut-down /start-up)

0 0 2
C5 Protection delay time (value of the option selected in parameter C4)                      (min.) 0 0 120
 

C6

Status of COOL relay with probe fault
0=OFF; 1=ON; 2=Average based on last 24 hours prior to probe fault;

3=ON-OFF as prog. C7 and C8

0 0 3
C7 Time relay ON in case of faulty probe                                                            (min.) 0 10 120
(If C7=0 and C8 0, the relay will always be OFF deenergised)
C8 Time relay OFF in case of fault of probe 1                                                       (min.) 0 5 120
(If C8=0 and C7 0, the relay will always be ON energised)
EP Exit to Level 1
dEF Leve l 2         DEFROST Control (if P0=0 Direct, Cold)
Level 3        Description                                   Values Min. Def. Max.
d0 Defrost frequency                                                                                  (h.) 0 96
(Time between two starts)
d1 Maximum defrost duration (0=defrost deactivated)                                            (min.) 0 255
 

d2

Type of message during defrost:
0=Current temperature; 1=Temperature at start of defrost; 0 2 2
2=Display dEF message
d3 Maximum duration of message 0 5 255
(time added at the end of the defrost)                                                            (min.)
d8 Calculated time between defrost periods: 0 0 1
0=Total actual time; 1 =Sum of times the compressor is on
EP Exit to Level 1
CnF Leve l 2         General status
Level 3        Description                                  Values Min. Def. Max.
P0 Type of operation 0=Direct, Cold;1=Inverted, Heat 0 1
P1 Delay of all functions on receiving electrical power                                            (min.) 0 0 255
P2 Access code (password) functions 0 0 2
0=Inactive; 1=Block access to parameters; 2=Keyboard lock
P5 Address (only systems with built-in communications) 1 1 255
P7 Temperature display mode                 0= Integer °C                  1=One decimal in ºC 0 1 3
2=Integer °F                  3=One decimal in °F
P9 Selection of probe type 0=NTC; 1=PTC 0 0 1
EP Exit to Level 1
tid Lev el 2          Access and information control
Level 3        Description                                  Values Min. Def. Max.
L5 Access code (Password) 0 99
PU Program version (Information)
Pr Program revision (Information)
EP Exit to Level 1
EP Exit Programming

WARNING: The default parameters by type of application have been defined for the most common applications. Check that these parameters are suitable for your installation.

DEFAULT SETTINGS BY APPLICATION (P3)
1 2 3 4 5 6 7 8
Multipurpose Frozen Fruit and Vegetables Fresh Fish Soft Drinks Bottle Racks AC Heat/ Incubators
SP 2 (35,6ºF) -18 (-0,4ºF) 10 (50ºF) 0 (32ºF) 3 (37,4ºF) 12 (53,6ºF) 21 (69,8ºF) 37 (98,6ºF)
d0 4 4 4 4 24 24 96
d1 20 20 20 20 20 20 0
P0 0 0 0 0 0 0 0 1
MESSAGES
L5 Access code (Password) request D
dEF Indicates a defrost is underway.(Only if parameter d2=2) D
E1 Probe 1 faulty (open circuit, crossover, NTC: temp. >110°C or <-55 °C

PTC: temp. >150 °C or <58 °C) – (equivalent limits in °F)

D S
  • Displays the message on the display
  • Shows the message in the AKONet software (Only AKO-D14023-C)

Technical specifications

Power supply AKO-D14023/D14024/D14123/D14124/D14125 . 230 V~ ±10 % 50/60 Hz 3.5 VA

  • AKO-D14120. . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V~ +8 % – 12 % 50/60 Hz 4 VA
  • AKO-D14023-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90-240 V ~ 50/60 Hz 6 VA
  • AKO-D14012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12/24 V ~– ±20% 2.5 VA
  • Maximum Voltage SELV circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
  • Comunication (Only AKO-D14023-C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus RTU RS485
  • Inputs (According to P4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 NTC/PTC
  • Relay COOL 16 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (EN60730-1: 12(9) A 250 V~)
  • Number of relay operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN60730-1: 100.000 operations
  • Types of probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTC AKO-149xx / PTC AKO-1558xx
  • Measurement range NTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +99,9 ºC (-58,0 ºF to 211 ºF)
  • PTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0 ºC to +150 ºC (-58,0 ºF to 302 ºF)
  • Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 ºC
  • Working environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10 to 50 ºC, humidity <90 %
  • Ambient storage humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30 to 70 ºC, humidity <90 %
  • Class of protection – front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65
  • Fixation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Panel-mounted with anchors
  • Panel cutout dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 x 29 mm
  • Front panel dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 x 38 mm
  • Depth AKO-D14023-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 mm
  • Other models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 mm
  • Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw terminals for cables up to 2.5 mm²
  • Rating of control device: built-in, automatic operation feature Type 1.B, for use in clean environments,
  • Class A software and continuous operation. Pollution classification 2 s/ UNE-EN 60730-1.
  • Double insulation between supply, secondary circuit and relay output.
  • Rated pulse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
  • Temperature during ball-pressure test Accessible parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 ºC
  • Parts which position active elements . . . . . . . . . . . . 125 ºC
  • Voltage and current as per EMC tests AKO-D14023/D14023-C/D14024/
  • AKO-D14123/D14124/D14125/ . . . . . . . . . 207 V, 17 mA
  • AKO-D14120 . . . . . . . . . . . . . . . . . . . . . . . . 105 V, 36 mA
  • AKO-D14012 . . . . . . . . . . . . . . . . . . . . . . . 9,6 V, 181 mA
  • Current of radio jamming supression tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 mA

AKO ELECTROMECÀNICA, S.A.
We reserve the right to supply materials which may be slightly different from those described in our Data Sheets. Updated information on our web site: www.ako.com ako@ako.com www.ako.com

  • Fax (34) 938 934 054
  • Tel. (34) 938 142 700
  • Av. Roquetes, 30-38 08812

Documents / Resources

AKO D14120 Temperature Controller [pdf] Instructions
D14120, D14123, D14012, D14023, D14023-C, D14024, D14124, D14125, D14120 Temperature Controller, D14120, Temperature Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *