SIEMENS ECHS100 4.17-in Hub in the Breaker Box
Arc Fault Circuit Interrupters (AFCI)
Identifying applications:
Used in Siemens and Murray load centers
Definition of product:
Arc fault circuit interrupter (AFCI) uses advanced electronic technology to provide maximum available protection against the effects of arcing faults.
Overview of the product:
- United States Fire Administration (USFA) reported:
– Annually, an estimated 28,300 residential electrical fires cause 360 deaths, 1,000 injuries, and $995 million in direct loss.
– 15% of residential electrical fires start in bedrooms.
– 47% of residential electrical fires are caused by the wiring. - Combination Type AFCI’s are required by the 2005, 2008, 2011, 2014 and 2017 National Electric Code ®
Product rating: UL listed
General features and benefits:
- 1 and 2 pole Combination Type AFCIs
- Exclusive LED trip indicators indicate cause of last trip (ie. Arcing fault or overcurrent condition.)
1-Pole Combination Type AFCI | |
LED indicator |
Last known trip condition |
ON | Arc fault |
OFF | Overcurrent |
2-Pole Combination Type AFCI | ||
LED indicator |
Last known trip condition | |
Yellow 1 | Yellow 2 | |
On | OFF | Arc Fault (Leg A) |
OFF | ON | Arc Fault (Leg B) |
OFF | OFF | Overcurrent |
Accessories
- Padlocking device: ECPLD1
Arc Fault Breaker Catalog Numbering System
Q | 1 | 20 | AFC | P |
Brand name | No. of Poles | Amperes | Special Applications | Packaging |
Q = Siemens MP = Murray | 1 = 1 2 = 2 |
15 = 15A 20 = 20A |
(blank) = Standard breaker AFC = Combination Type Arc Fault Circuit Interrupter |
(blank) = cardboard packaging P = Clamshell packaging for retail |
Ground Fault Circuit Interrupters (GFCI)
Identifying applications:
Used in Siemens and Murray load centers
Definition of product:
Ground fault circuit interrupter (GFCI) is designed to protect against severe electrical shock or electrocution from ground faults. Ground faults occur when the electrical current in an appliance strays outside its normal path, and the human body becomes part of the path through which the electrical current may flow.
Overview of the product:
- GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water.
- Current imbalances of 4-6 milliamps or more between load conductors will cause the ground fault sensor to trip the circuit breaker.
Product rating: UL listed, CSA Certified
General features and benefits:
- Available in 1-pole (15-30A) and 2-pole (15-60A)
- Common uses: spas, hot tubs, kitchens, bathrooms, garages, etc.
- Resists false tripping (shielded to prevent RF interference)
- Standard 1 inch per pole format with plug-in design
- Provides Class A GFCI protection
Ground Fault Breaker Catalog Numbering System
Q | F | 1 | 20 | P |
Brand name | Ground Fault Indication | No. of Poles | Amperes | Packaging |
Q = Siemens MP = Murray |
F = Ground Fault; 5mA personnel protection E = Ground fault; 30mA equipment protection |
1 = 1 2 = 2 |
15 = 15A 20 = 20A 30 = 30A 40 = 40A 50 = 50A 60 = 60A |
(blank) = cardboard packaging P = Clamshell packaging for retail |
Load centers PL and ES Series
Identifying applications:
Residential and multi-family electrical distribution
Definition of product:
A load center is the point where all of the electricity enters and is distributed throughout the house.
Overview of the product:
- Copper Bus and Aluminum Bus variations
- 100-225A, 1 and 3-phase, NEMA 1 and 3R
- Main Lug and Main Breaker options
Product rating: UL listed
General features and benefits: PL Series
- Copper Bus
- Convertible from Main Lug to Main Breaker
- 12-70 circuits/spaces
- 2 Ground Bars factory installed
- INSTA-WIRE™ neutrals and grounds
Catalog Numbering System
Siemens load centers meet or exceed the following standards.
- UL50 – Electric Cabinets and Boxes
- UL67 – Electric Panelboards
- UL486 – Wire Connectors
- UL489 – Molded-Case Circuit Breakers
- UL869 – Service Equipment
- UL943– Ground Fault interrupters (Class A – Personnel Protection)
- Federal Specification W-P-115b – Panel Power Distribution
- Federal Specification W-C-375B – Circuit Breakers
- NEC
- NEMA 250
Underwriters’ Laboratories, Inc. reference file numbers:
- Series Connected Circuit Breaker Information is recognized by UL under file #E10848(N)
- Load Centers Listed by UL under file #E10703
- Load Centers UL recognized components found under file #E10703, Volume 6 and 7. (Also referenced under the recognized components directory – section QEUY2)
- EQ Circuit Breakers are Listed by UL under file #E82615
Load center Accessories
Ground Bars:
2 included in all PL Series load center. Sold separately for ES Series.
EC2GB15, EC3GB27
Filler Plates:
Covers twist outs from a dead front without a breaker to fill the space.
ECQF3P
Hubs:
For use on outdoor load centers for water tight connection to conduit fittings.
ECHS000, ECHS075,
ECHS100, ECHS125,
ECHS150, ECHS200
QN and MPD
Identifying applications:
Used as a main breaker in small circuit load centers, circuit breaker enclosures, meter mains and meter combos. Used as a branch breaker to be a main disconnect for main lug only load centers.
Definition of product:
The QN is used as both a branch breaker and a main breaker in applications which require a two pole, 120/240V AC breaker.
Overview of the product:
- 150, 175, and 200 A
- 10k, 22K, 65K AIC
Product rating: UL listed
General features and benefits:
- Available with a reverse handle mechanism
Accessories
- Padlocking device ECQLN3
QN Breaker Catalog Numbering System
QN | 2 | 150 | R | H | |
Interrupting Rating | Brand name | No. of Poles | Amperes | Handle operation | Interrupting Rating |
(blank) =
10kAIC |
QN = Siemens |
2 = 2 | 150 = 150A | (blank) = vertical applications |
(blank) = 10kAIC |
175 175A | |||||
200 = 200A | |||||
H = 65kAIC | MPD = Murray |
R = horizontal applications |
H = 22kAIC |
MBK Breaker
Identifying applications:
Used in Ultimate load centers, 1 phase PL and ES load centers, riser panel load centers, and generator ready load centers
Definition of product:
Main breaker used in various Siemens load centers
Overview of the product:
- 2 Pole
- 100, 125, 150, 200, 225 A
- 22K AIC
Product rating: UL listed
General features and benefits:
- 00 and 125A breakers have a smaller footprint than the 150A+ MBKs so they cannot be installed in 150A+ load centers for increased installation safety
Accessories
- Padlocking device
ECQLN3
Catalog numbers
Siemens:
MBK100A, MBK125A, MBK150A, MBK200A, MBK225A
Murray:
MBK100M, MBK125M, MBK150M, MBK200M, MBK225M
QP Breakers
Identifying applications:
Used as a 1” pole center branch breaker for applications that require plug-in (QP) or bolt-on (BL) connections
Definition of product:
1” pole center branch breaker
Overview of the product:
- 1, 2, and 3 Poles (common trip)
- Available as 120V, 120/240V, 240V AC
- 10-125A
- 10K, 22K, 65K AIC
Product rating: UL listed
General features and benefits:
- Time saving INSTA-WIRE™ feature
Accessories
- Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECPLD3, ECPLD3R, ECQLD3, ECQLD4, ECQTH4
- Handle tie: ECQTH3
- Mechanical interlock: ECQML12
- Handle blocking device: ECQL1
Standard Breaker Catalog Numbering System
Q | 1 | 20 | H |
Brand name | No. of Poles | Amperes | Interrupting Rating |
Q = Siemens plug-in MP = Murray plug-in |
1 = 1 2 = 2 3 = 3 |
10 = 10A 15 = 15A 20 = 20A 25 = 25A 30 = 30A 35 = 35A 40 = 40A 45 = 45A 50 = 50A 60 = 60A 70 = 70A 80 = 80A 90 = 90A 100 = 100A 110 = 110A 125 = 125A |
(blank) = 10kAIC H = 22kAIC HH = 65kAIC |
QT Breakers
Identifying applications:
Used as branch breakers in Siemens load centers
Definition of product:
1/2” pole centers branch breakers offered as a duplex, triplex, and quadplex.
Overview of the product:
- 120/240V AC
- Available as 120V, 120/240V, 240V AC
- 10K AIC
- 15-50A
Product rating: UL listed
General features and benefits:
- Space saving design allows two poles to fit in a 1” panel space
- Available without a rejection tab so it can be used with an unnotched stab (for panels built before the 1970s)
Accessories
- Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECQLD4
- Handle tie: ECQTH2
- Handle blocking device: ECBX23IM
QT Breaker Catalog Numbering System
Q | 15 | 15 | NC | |
Brand name | No. of Poles | Amperes | Amperes | Special Application |
Q = Siemens | (blank) = Duplex | 15 = 15A | 15 = 15A | (blank) = standard |
20 = 20A | 20 = 20A 25 = 25A 30 = 30A 35 = 35A 40 = 40A 45 = 45A 50 = 50A |
|||
MP = Murray | 2 = Triplex or Quadplex |
30 = 30A | NC = Non CTL for replacement use only in panels manufactured before 1968. |
|
CT = Triplex CT2 = Quadplex |
One Pole Applications
*These are typical installations. Check with local codes, existing wire size installed, and ratings of the appliances before proceeding.
Appliance | Watts | Voltage | Amps | Breaker |
Dishwasher | 1200 | 120 | 20 | Q120 |
Lighting Fixture | 1200 | 120 | 15 | Q115 |
Refrigerator/ Freezer | 300/350 | 120 | 20 | Q120 |
TV/DVD | 300 | 120 | 20 | Q120 |
Washing Machine | 1200 | 120 | 20 | Q120 |
Waste Disposal | 300 | 120 | 20 | Q120 |
Two Pole Applications
Appliance | Watts | Voltage | Amps | Breaker |
Built-in Oven | 4500 | 120/240 | 30 | Q230 |
Central Air | 6000 | 120/240 | 50 | Q250 |
Clothes Dryer | 5000 | 120/240 | 30 | Q230 |
Range | 12000 | 120/240 | 50 | Q250 |
Range Top | 6000 3300 |
120/240 | 30
20 |
Q230 Q220 |
Water Heater | 4000 | 120/240 | 30 | Q230 |
Surge Protection Device
Identifying applications:
Provides surge protection for all branch circuits in the load center of the residence at no loss of load center spaces
Definition of product:
2” Wide plug-on containing two one pole circuit breakers and a surge arrester
Overview of the product:
- Utilizes Siemens-built 150V AC, 40mm, metal oxide visitor with maximum impulse rating of 40 kA
- Rated 120/240V AC
Product rating: UL listed
General features and benefits:
- Easy to install and perfect for retrofit
- LEDs provide protection status
- $20,000 warranty for the residential electrical system (Load center, internal wiring, receptacles, dimmers, hard wired appliances)
- Surge protection at no loss of load center spaces
Surge Protection Breaker Catalog Numbering System
QSA | 20 | 20 | SPD |
Brand name | Amperes | Amperes | Special Application |
QSA = Siemens MSA = Murray | 15 = 15A 20 = 20A |
15 = 15A 20 = 20A |
SPD = Surge Protection Device |
Breaker Accessories
Padlocking Device:
For locking breaker in “OFF” position. Note “ON” position does not affect breaker functionality.
ECPLD1, ECPLD2,
ECPLD2R, ECPLD3,
ECPLD3R, ECQLD3,
ECQLD4, ECQLN3,
ECQTH4
Available for: QP, BL, QT, QN, QNR, 150A+ MBK
Handle Tie:
Provides simultaneous switching of 2 adjacent handles
ECQTH2, ECQTH3
Available for: 2 Pole QP and QTs
Mechanical Interlock:
Mechanically interlocks two breakers so it is impossible for both to close at the same time ECQML12
Available for: QP and BL
Handle Blocking Device:
For holding device in “ON” and “OFF” position. Not a lockout/tagout device ECQL1, ECBX231M
Available for: QP, BL, QT
Sustainable solutions from Siemens. Ready today for the home of tomorrow.
VersiCharge™ Electric vehicle charging stations for home and fleet
- Choice of four wiring methods to suit every install
- Simple, intuitive user controls
- Adjustable amperage output
- 30 A and 70 A models to suit present and future vehicles
- Unmatched feature set at competitive price point
- Versi Charge SG is Smart Grid ready
– Wireless communications
– User and utility programmable
– Optional revenue grade metering
– Available in multiple colors to match decor
Customer Support
Legal Manufacturer
Siemens Industry, Inc.
3617 Parkway Ln
Peachtree Corners, GA 30092
United States of America
Telephone: +1 800-333-7421
www.usa.siemens.com/retail
Order No. RPPG-REFG1-0722
© 07.2022, Siemens Industry, Inc.
This document contains a general description of available technical options only, and its effectiveness will be subject to specific variables including field conditions and project parameters. Siemens does not make representations, warranties, or assurances as to the accuracy or completeness of the content contained herein. Siemens reserves the right to modify the technology and product specifications in its sole discretion without advance notice.