SHOWVEN LOGO

SHOWVEN HC8200 Type Waver Sparkular

SHOWVEN HC8200 Type Waver Sparkular

Thanks for choosing SPARKULAR® WAVER, we wish it will sparks up your show. Please read the following manual carefully before operating this product

Safety Instructions

  • Unauthorized repair are prohibited, it may cause serious incident.
  • Please keep the device dry.
  • Make sure lid of feeding hopper are well covered when use SPARKULAR® WAVER.
  • Accidentally burning of consumable can only use sands to extinguish.
  • Consumable should keep away from moisture and stored in a dry sealed environment.
  • Check whether there is consumable aggregate in the output nozzle both before and after each show, if any, please clean it up, or it will affect the firing effect, damage machine, even cause serious incident.
  • There will be some sparks drop to ground, make sure there are no flammable objects such as carpet on the ground within the safety radius of the machine.
  • Suggest to use HC8200 MEDIUM for indoor events.
  • The SPARKULAR® WAVER power supply cable maximum allowed cascade of 6pcs (220V version) / 3pcs (110V version), exceed connecting may result in damage or even cause fire.
  • Cover the output nozzle of SPARKULAR® WAVER is forbidden, inspect the machine before each show, making sure no objects or material will block the output nozzle.
  • Never touch the nozzle of SPARKULAR® WAVER danger of getting burnt.
  • Never touch the sparks which shooting out from the nozzle.

Safety Distance

  • Safety distance for SPARKULAR® WAVER divided into two parts safety radius around machine (a) and safety distance at firing direction (b). No person and flammable materials are allowed to stay inside the safety isolation zone when SPARKULAR® WAVER was armed.
  • The safety radius around machine depends on effect height (consumable HC8200 type), with a radius of 1m or 1.5m.
  • For safety distance at firing direction equals to maximum firing height + 1m. SPARKULAR® WAVER with maximum 90 waving firing angles, when firing wave sequence the safety isolation zone is a three-dimensional sector area.
    HC8200 Type Max. Effect Height Safety Radius around

    SPARKULAR (a)

    Safety Distance at

    Firing Direction (b)

    Medium 3.5m 1m 4.5m
    LARGE 4.5m 1.5m 5.5m
  • The SPARKULAR® WAVER safety isolation zone is a three-dimensional space with a cross-section of 180° sector enclosed by a and b (check below diagram). We can understand it as a safety area formed by a safety column with diameter of a, height of b rotate of ±90 degrees. Unauthorized persons and objects are strictly prohibited from entering. Depending on the firing sequence / angles the sector area changes accordingly.
  • For angled firing, the safety distance both around machine and firing direction should shift accordingly.
  • In windy environment, increase the safety distance according to the wind direction and speed.
  • Sparks and consumables from the machine can lead to serious eye injury. Always wear safety goggles when enter the safety zone.

SHOWVEN HC8200 Type Waver Sparkular 1

Description
SPARKULAR® WAVER is 180 degree waving spark effect originally developed by SHOWVEN. It can firing in any single direction between -90 to 90 degree or in waving sequences etc. Various editable sparks effect brings infinite creativity to your stage.

Technical Specifications

  • DIMENSION: 300290273mm
  • WEIGHT: 15.5kg
  • VOLTAGE: AC200-240V / AC100-120V, 50/60Hz
  • WORK POWER: 500W
  • EFFECT HEIGHT ADJUSTBLE: YES
  • EFFECT ANGLE ADJUSTBLE: -90°~ 90° (180° waving angles)
  • INTERFACE: 3-pin and 5-pin XLR, POWER IN/OUT
  • CONTROL: 6 DMX channels
  • WORK TEMP.: -20C~40C
  • CONSUMABLE AND EFFECT HEIGHT: LARGE (3-4.5m), MEDIUM (2.5-3.5m)

Structure of SPARKULAR® WAVERSHOWVEN HC8200 Type Waver Sparkular 2

  1. Feeding Hopper Lid
  2. Output Nozzle
  3. ARM alarming light
  4. Display Screen
  5. Power Switch
  6. Fuse
  7. Power IN
  8. Power OUT
  9. 3-PIN DMX IN
  10. 5-PIN DMX IN
  11. 5-PIN DMX OUT
  12. 3-PIN DMX OUT

Bottom panelSHOWVEN HC8200 Type Waver Sparkular 3

Operation Panel

Keypad areaSHOWVEN HC8200 Type Waver Sparkular 4

  • MENU: Press enter setting interface
  • UP: Parameter up
  • DOWN: Parameter down
  • MONI: Status monitoring of main part inside machine

Monitoring Interface
From this interface, we can check the voltage and motor status of machine.

SHOWVEN HC8200 Type Waver Sparkular 5

RFID areaSHOWVEN HC8200 Type Waver Sparkular 6

RFID card come with consumable HC8200 bags, swiping card to identify parameters and types of granules. The RFID card is disposable, one card can only use one time. Each card can increase single machine 20min working time, the maximum recharge time for SPARKULAR® WAVER is 30min.

ARM alarming light

  • ON: DMX connected or wireless remote function ON.
  • BLINK: DMX armed, ready for firing
  • OFF: No DMX connection and wireless remote function OFF.

Display Interface

  1. Main Interface:SHOWVEN HC8200 Type Waver Sparkular 7
    Background color of DMX area: red means DMX connected. Background color of TEMP area: red means heating chamber temp. reached setting temp. machine is ready for firing. Indicator light status on power switch: flash means machine is heating up, long on means temp. reached setting temp.
  2. Error information
    Error information Explanation
    E0 System IC Systematic error
    E1 Motor condition Blower motor, shaft motor or feeding motor error
    E2 Temp. Sensor Temperature sensor is not connected or damaged
    E3 P Temp. Over Machine shutdown due to chassis over temperature
    E4 Time Remain Firing time is insufficient, please swipe RFID card
    E5 K Temp. Over Machine shutdown due to heating chamber over temperature
    E6 Heat Fail Heating fail, problem on heating PCB or mainboard
    E7 Tip Over Tilt sensor activated when machine slant over 45 degrees
  3. Set Up Menu
    Press “MENU” enter setup menu, press LEFT, RIGHT to choose main menu, advanced menu or factory menu. Press “EIDT” can entering related menu and setting up related parameters.SHOWVEN HC8200 Type Waver Sparkular 8
  4. Main Menu
    Parameters in main menu show in below table, press “UP”/ “DOWN” to change the value, please remember to press “SAVE” to save the setting.
    Options Range Default Explanation
    Set DMX Address 1-512 1 Set DMX Address
    Manual Heat ON/OFF OFF Manual heat ON/OFF setting
    Manual Fountain ON/OFF OFF Manual Fountain ON/OFF setting
    Sequence 2 – 72 2 Preset sequence setting
    Max. Angle -90°~90° -90° Max. Angle limit
    Min. Angle -90°~90° 90° Min. Angle limit
    Invert ON/OFF OFF When turned on, all angles will be mirrored.
    Head to middle ON/OFF ON When ON and Channel 1 DMX value is 0, output nozzle will back to middle position after running a preset sequence.

Advanced Menu

Options Range Default Explanation
 

Set Temperature

 

500-620

 

580

Setup SPARKULAR® heat chamber temperature
Auto Clear Delay 0.1-0.9s 0.1s Automatic clear material time setting
Wireless 2.4G ON/OFF OFF 2.4G wireless function setting
LCD Backlight ON/OFF ON LCD backlight setting
Density 50-100 100 Feeding amount
 

Mode Selection

 

Factory Mode User Mode

 

User Mode

Factory mode is for engineer only. When in Factory mode machine

can’t controlled by DMX console

Default Parameter ON/OFF OFF Parameters reset to default setting
Motor Protect ON/OFF ON Motor protect function
 

Tip Over

 

ON/OFF

 

ON

Tilt function switch, when machine slant over 45 degree it will stop

working.

 

Standby Switch

 

ON/OFF

 

OFF

When ON, the machine can firing only when heating up was finished
Motor Disabled ON/OFF OFF Motor can’t waving when OFF
Key Sound ON/OFF ON Keypad press sound setting

For better performance of SPARKULAR® WAVER, please don’t change the default value without permission from SHOWVEN®.

DMX Channel Mode
SPARKULAR WAVER occupies 6 operational channels. First channel is for effect height, second channel for effect trigger and clear material etc.

Channel Function Value
CH1 Manual Angle setup 0~255: angle change from -90° to 90°

128: straight upward (0°)

CH2 Manual Nozzle Waving Speed setup 0 and 255: Max Speed

1~254: Speed increase

 

CH3

 

Firing ON/OFF

0~15: Firing OFF

16~90: Firing height low 91~170: Firing height medium 171~255: Firing height high Maxi. Single firing duration is 60s

 

CH4

 

n/a

 

Reserved

 

CH5

 

Preset sequence setup

0-2: no preset sequence

3-255: preset sequence

DMX value = 2 + Sequence No.*2.55 (ROUND OFF)

 

CH6

 

Mode setup

0~49: Heating Up OFF (Emergency Stop)

50~200: Heating Up ON

201~255: Heating Up OFF (Emergency Stop)

Channel 1 (CH1): Manual Angle Setup
SPARKUALR WAVER output nozzle can be stayed at any angle between -90° to 90°, below is a list of typical angles used in our preset sequence with related DMX value.

Angle No. Angle DMX value
1 90° 5
2 75° 24
3 60° 47
4 45° 66
5 30° 85
6 15° 108
7 128 or 0
8 -15° 148
9 -30° 169
10 -45° 190
11 -60° 213
12 -75° 234
13 -90° 255

SHOWVEN HC8200 Type Waver Sparkular 9

Firing Sequence
SPARKULAR WAVER has 72 preset sequences, operator use related channel DMX value or sequence No. to access certain sequence. Below, you can find sequence list.

No. Ignition angle Description Firing

Duration

CH5 DMX

Reference Value

1 Any angle Clear material Depends

on CH3

3-5
2 -90° Fixed angle firing Depends

on CH3

6-7
3 -75° Fixed angle firing Depends

on CH3

8-10
4 -60° Fixed angle firing Depends

on CH3

11-12
5 -45° Fixed angle firing Depends

on CH3

13-15
6 -30° Fixed angle firing Depends on CH3 16-17
7 -15° Fixed angle firing Depends

on CH3

18-20
8 Fixed angle firing Depends on CH3 21-22
9 15° Fixed angle firing Depends

on CH3

23-25
10 30° Fixed angle firing Depends on CH3 26-28
11 45° Fixed angle firing Depends

on CH3

29-30
12 60° Fixed angle firing Depends on CH3 31-33
13 75° Fixed angle firing Depends

on CH3

34-35
14 90° Fixed angle firing Depends on CH3 36-38
15 (-90°) ~ 90° Slow waving once 8s 39-40
16 90°~ (-90°) Slow waving once 8s 41-43
17 (-90°)~ 90° ~(-90°) Slow waving once 14s 44-45
18 (-75°)~ 75°~ (-75°) Slow waving once 12s 46-48
19 (-60°)~ 60° ~ (-60°) Slow waving once 10s 49-50
20 (-45°)~ 45° ~ (-45°) Slow waving 3 times 17s 51-53
21 (-30°)~ 30° ~ (-30°) Slow waving 3 times 12s 54-56
22 (-15°)~ 15° ~ (-15°) Slow waving 3 times 7s 57-58
23 (-90°)~ 90° ~ (-90°) Medium waving 5 times 12s 59-61
24 (-75°)~ 75° ~ (-75°) Medium waving 5 times 10s 62-63
25 (-60°)~ 60° ~ (-60°) Medium waving 5 times 8s 64-66
26 (-45°)~ 45° ~ (-45°) Medium waving 5 times 7s 67-68
27 (-30°)~ 30° ~ (-30° Medium waving 5 times 5s 69-71
28 (-15°)~ 15° ~ (-15°) Medium waving 5 times 3s 72-73
29 (-60°)~ 60° ~ (-60°) Fast waving 10 times 5s 74-76
30 (-45°)~ 45° ~ (-45°) Fast waving 10 times 5s 77-79
31 (-30°)~ 30° ~ (-30°) Fast waving 10 times 4s 80-81
32 (-15°)~ 15° ~ (-15°) Fast waving 10 times 3s 82-84
33 (-75°)~ 0° ~ (-75°) Fast waving 10 times 4s 85-86
34 (-60°)~ 0° ~ (-60°) Fast waving 10 times 3s 87-89
35 (-45°)~ 0° ~ (-45°) Fast waving 10 times 2s 90-91
36 (-30°)~ 0° ~ (-30°) Fast waving 10 times 2s 92-94
37 75° ~ 0° ~ 75° Fast waving 10 times 5s 95-96
38 60° ~ 0° ~ 60° Fast waving 10 times 4s 97-99
39 45° ~ 0° ~ 45° Fast waving 10 times 3s 100-101
40 30° ~ 0° ~ 30° Fast waving 10 times 3s 102-104
41 (-90°)~ 0° ~ (-90°) Slow waving twice 11s 105-107
42 (-75°)~ 0° ~ (-75°) Slow waving twice 10s 108-109
43 (-60°)~ 0° ~ (-60°) Slow waving twice 8s 110-112
44 (-45°)~ 0° ~ (-45°) Slow waving twice 6s 113-114
45 (-30°)~ 0° ~ (-30°) Slow waving twice 5s 115-117
46 90° ~ 0° ~ 90° Slow waving twice 11s 118-119
47 75° ~ 0° ~ 75° Slow waving twice 10s 120-122
48 60° ~ 0° ~ 60° Slow waving twice 8s 123-124
49 45° ~ 0° ~ 45° Slow waving twice 6s 125-127
50 30° ~ 0° ~ 30° Slow waving twice 5s 128-130
51 (-90°)~ 0° ~ (-90°) Medium waving 5 times 7s 131-132
52 (-75°)~ 0° ~ (-75°) Medium waving 5 times 6s 133-135
53 (-60°)~ 0° ~ (-60°) Medium waving 5 times 5s 136-137
54 (-45°)~ 0° ~ (-45°) Medium waving 5 times 4s 138-140
55 (-30°)~ 0° ~ (-30°) Medium waving 5 times 3s 141-142
56 90° ~ 0° ~ 90° Medium waving 5 times 7s 143-145
57 75° ~ 0° ~ 75° Medium waving 5 times 6s 146-147
58 60° ~ 0° ~ 60° Medium waving 5 times 5s 148-150
59 45° ~ 0° ~ 45° Medium waving 5 times 4s 151-152
60 30° ~ 0° ~ 30° Medium waving 5 times 3s 153-155
61 90° ~ 45° ~ 90° Slow waving 3 times 10s 156-158
62 90° ~ 30°~ 90° Slow waving 3 times 13s 159-160
63 (-90°) ~ (-45°) ~ (-90°) Slow waving 3 times 10s 161-163
64 (-90°) ~ (-30°) ~ (-90°) Slow waving 3 times 12s 164-165
65 (-90°) ~ 0° Slow waving gradually

decreases angle

18s 166-168
66 90° ~ 0° Slow waving gradually decreases angle 19s 169-170
67 (-90°) ~ 90° Slow waving gradually decreases angle 41s 171-173
68 0° ~ (-90°) Slow waving once 5s 174-175
69 (-90°) ~ 0° Slow waving once 5s 176-178
70 0° ~ 90° Slow waving once 5s 179-180
71 90° ~ 0° Slow waving once 5s 181-183
72 Fixed angle firing Depends

on CH3

184-185

DMX control example 1: firing sequence No. 42

  1. Set output nozzle straight up
    CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128
  2. Set preset Sequence No. 42
    CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 108, CH6 = 128
  3. Firing 1s
    CH1 = 128, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 108, CH6 = 128

DMX control example 2: firing sequence No. 8, firing time 10s

  1. Set output nozzle straight up
    CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128
  2. Set preset Sequence No. 8
    CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 21, CH6 = 128
  3. Firing
    CH1 = 128, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 21, CH6 = 128 Keep 10s.
  4. Firing OFF
    CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128

Wireless Control Mode:SHOWVEN HC8200 Type Waver Sparkular 10

When use remote controller, please disconnect DMX cable connection, set machine to Wireless 2.4G to ON status. Match machine with remote controller by Press “A” on remote controller when machine at Wireless Control interface.

  • A: OFF / SET, Firing OFF, SET means match machine with remote controller.
  • B: Firing, vertical up (0°)
  • C: Firing, according to the sequence setting on machine
  • D: Clear Material 3s.
    Please replace the battery when the indicator light on remote controller is weak. Battery mode: 9V stacked battery. Remote controller for SPARKULAR WAVER is optional accessory.

Operation Guide

  1. Install SPARKULAR®WAVER
    1. SPARKULAR® WAVER can only be installed horizontally.
    2. Make sure the machine is securely installed to avoid tipping.
    3. Check carefully the output nozzle of each machine, make sure the output nozzle is in good shape and there is no powder aggregate.
  2. Fill SPARKULAR® WAVER
    1. Open powder bags and fill the feeding hopper.
    2. Choose correct consumable according to the application scenario. SPARKULAR® WAVER can only use HC8200 LARGE and MEDIUM.
    3. Please be noted that there may sparks or remains fall to the ground. Make sure no flammable material on ground in the safety zone.
    4. Maximum effect height: HC8200 LARGE is 4.5m, HC8200 MEDIUM is 3.5m.
    5. Make sure the lid of hopper is locked tight after filling.
  3. Connect Power / DMX cable
    1. Connect a power cable to the POWER IN socket of SPARKULAR® WAVER. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded.
    2. If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine.
    3. The SPARKULAR® WAVER power supply cable maximum allowed cascade is 6 units (220V version) / 3pcs (110V version). Do not connect exceed units to a single electrical circuit.
    4. Power ON all SPARKULAR® WAVER.
    5. Assign DMX address for each unit of SPARKULAR® WAVER. If use SHOWVEN host controller or FXcommander to control the machine please allocate a unique DMX address for each unit of machine. If use remote controller to control SPARKULAR® WAVER wirelessly, please set machine to wireless ON status and match machine with remote controller. For DMX cable control please execute below operations (f to h).
    6. Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® WAVER, connect the male connector end of DMX cable to your DMX controller (FXcommander, HOST CONTROLLER, light console etc).
    7. Connect a DMX cable to the DMX OUT of previous machine, and the other end of to the DMX IN of next machine. Connect all devices in series in this way.
    8. Suggest to plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission (SHOWVEN DMX splitter 8 with bidirectional signal transmission, thus can get signal feedback from device).
  4. Activate SPARKULAR® WAVER by swipe RFID card
    1. Swipe an RFID card. Read the card as show below. SPARKULAR® WAVER shows time remain if read successfully. SPARKULAR® WAVER report E4 when remaining time is less than 10 minutes.
    2. Please note each RFID card come with 200g package HC8200 can increase single machine 20min working time, the maximum recharge time for SPARKULAR® WAVER is 30min, when time remain reached 30min, it can’t recharge anymore RFID card.SHOWVEN HC8200 Type Waver Sparkular 11
  5. Programming and Firing
    1.  Programming SPARKULAR® WAVER, set the firing sequences etc.
    2. Heating up, it takes around 5min, it varies according to the voltage and environment temperature.
    3. Make sure the prescribed safety zone of related firing sequences are clear.
    4. Suggest to clear material before firing.
    5. Firing. In order to prevent overheat in the heating chamber and protect machine, the maximum continuous firing time for SPARKULAR® WAVER is 60s.
    6. The operator should always have a clear view of the device, so that he/she can stop the show immediately when there is danger.
    7. Running preset sequence No.1 to clear material for SPARKULAR® WAVER after show, clear material will remove the remaining particles from heating chamber.
      NOTE: If use SHOWVEN HOST CONTROLLER ZK6200/6300 to control the firing, please press “F3” to choose “CIRCLE FLAMER-6CH”, then set the firing sequence, as for preset sequence the firing duration is fixed, so please set firing duration 1s. Please do allocate different DMX address for each unit of SPARKULAR WAVER (6 channels), otherwise it will cause signal interference.
  6. Turn Off and clean up
    1. Power off SPARKULAR® WAVER, allow SPARKULAR® WAVER to cool down.
    2. Disconnect all POWER and DMX cables.
    3. Empty the remaining HC8200 in hopper, and store the remaining HC8200 in a dry sealed bottle for next time use. Never touch the output nozzle of SPARKULAR® WAVER when empty the hopper. DANGER OF GET BURNT!
    4. Operators can use handheld vacuum cleaner to empty the feeding hopper. Do make sure the machine was cool down when clean it. Do NOT use high-power vacuum cleaners to avoid hot consumables being sucked into the vacuum cleaner from the heating chamber and cause fire.
    5. Clean the surroundings to remove powder residues.

Maintenance

  1. Empty the feeding hopper before shipment of machine.
  2. Empty the feeding hopper if long time not use, for high humidity environment we suggest to empty feeding hopper after each show.
  3. Clear material both before and after the show.

Warranty Instructions

  • Sincere thanks for your choosing our products, you will receive quality service from us
  • The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
  • We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission Below situations NOT included in warranty service:
  • Damage caused by use other type of consumable which is not from SHOWVEN® or SHOWVEN® authorized distributor.
  • Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
  • Disassemble, modify or repair products without permission;
  • Damage caused by external reasons (lightning strike, power supply etc.)
  • Damage caused by improper installation or use; For product damage not included in warranty range, we can provide paid service. Invoice is necessary when applying for maintenance service from SHOWVEN®.

SHOWVEN HC8200 Type Waver Sparkular 12

Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, 410300, Changsha, Hunan, P.R.China.

Documents / Resources

SHOWVEN HC8200 Type Waver Sparkular [pdf] User Manual
HC8200 Type, HC8200 Type Waver Sparkular, Waver Sparkular, Sparkular

References

Leave a comment

Your email address will not be published. Required fields are marked *