START HERE

  1. Carefully unpack box.
    SECURITY BRANDS Ridge RTE Request to Exit Station -
  2. Make sure you have all items shown here.(Screwdriver not shown)
    SECURITY BRANDS Ridge RTE Request to Exit Station - Screwdriver

    What’s what?

    Important components labeled
    SECURITY BRANDS Ridge RTE Request to Exit Station - LockRTE Unit Front Panel(Front)
    SECURITY BRANDS Ridge RTE Request to Exit Station - Pairing Buttons
    RTE Unit Front Panel(Back)
    Internal wiring not shown for clarity.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Connection TerminalsTransceiver
    Shown with cover removed.
    Internal wiring not shown for clarity.

  3. Unlock and remove Front Panel of RTE Unit; then using included Carriage Bolts and Hex Nuts, attach unit to pedestal as shown.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Panel
  4. Using Tek screws, zip ties, or other means of securing, attach Transceiver to inside wall or another surface inside gate operator.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Panel1
    Warning icon CAUTION!
    The Transceiver is not weatherproof and must be mounted inside a weatherproof enclosure. Internal components can be damaged if exposed to the elements.
    Failure to comply will VOID WARRANTY.
    SECURITY BRANDS Ridge RTE Request to Exit Station - icon WARNING!
    AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
    ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING!
    REVERSING or other SAFETY DEVICES SHOULDALWAYS BE USED!
  5. a Connect Transceiver
    Gate Operator Timer-to-Close OFF
    SECURITY BRANDS Ridge RTE Request to Exit Station - Panel2
    Consult gate operator or door opener manual for exact connections.
    Terminals vary widely across manufacturers and models.
    5bConnect Transceiver
    Gate Operator Timer-to-Close ON
    SECURITY BRANDS Ridge RTE Request to Exit Station - Panel3
    Consult gate operator or door opener manual for exact connections. Terminals vary widely across manufacturers and models.
    Warning icon CAUTION!
    A closing gate can cause injury to persons or damage to property.
    ALWAYS USE SAFETY DEVICES!
  6. a Remove Transceiver cover; then hold down Programming Button on circuit board for 3 seconds and let go.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver6b Remove RTE Unit Front Panel.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver1
    6c Hold down both Pairing Buttons until Status LED flashes. Let go of Button 2, and continue holding Button 1 only until Status LED flashes again.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver2
    6d Relay on Transceiver should click and Programming LED should go out. Pairing is now complete.
    SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver3SECURITY BRANDS Ridge RTE Request to Exit Station - icon CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING THIS STEP AS IT TRIGGERS THE RELAY!
  7. Press Exit Button on RTE Unit and confirm gate/door opens.
    (If nothing happens, repeat Step 6. If gate/door is held open, see Troubleshooting section on Page 4.)
    SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver4
    SECURITY BRANDS Ridge RTE Request to Exit Station - icon CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING
    THIS STEP AS IT TRIGGERS THE RELAY!

SECURITY BRANDS Ridge RTE Request to Exit Station - icon1 INSTALLATION COMPLETE!
Your system is ready to use.

A The RTE Unit can be disabled and re-enabled at any time by taking the Key Switch Keys and using the Key Switch located below the Exit Button.

SECURITY BRANDS Ridge RTE Request to Exit Station - Transceiver5
B Transceiver Reset Procedure
This procedure is used to unpair all devices from the Transceiver.
Step 1 – Remove screws and remove Transceiver cover.
Step 2 – Press and hold Programming Button until Programming LED starts to flash.
Button must be held for about 30 seconds. Once flashing stops, all devices have been unpaired from Transceiver and reset is complete.
Step 3 – Replace Transceiver cover and secure screws.

Troubleshooting

RTE U nit is holding gate/door open
IMPORTANT: GATE/DOOR MUST BE CLOSED BEFORE COMPLETING THIS PROCEDURE!
Step 1 – Press Exit Button on RTE Unit to close gate/door if it is not already closed.
Step 2 – Hold down both Pairing Buttons and pay attention to Status LED.
Step 3 – When Status LED flashes twice, continue holding BOTH buttons.
Step 4 – When LED flashes twice again, continue holding Button 1 ONLY until Status LED flashes multiple times.
Now the RTE unit should only hold the gate/door open momentarily.

© 2022 Security Brands, Inc. All rights reserved.

SECURITY BRANDS Ridge - logo2QSG-14RTE433-EN Rev. E (9/2022)