Dwyer Series V6 Flotect® Flow Switch

Specifications - Installation and Operating Instructions

Bulletin E-22

Product Overview

The Series V6 Flotect® Flow Switch is an inexpensive, explosion-proof flow switch designed for use with air, water, or other compatible gases and liquids. It offers three configurations: factory-installed in a tee, with a trimmable vane for field adjustment, or low-flow models with an integral tee and adjustable valve. All models are available with an optional enclosure that is UL and CSA listed, or Directive 2014/34/EU (ATEX) compliant.

The switch is suitable for hazardous locations and meets stringent safety standards, including ATEX and IECEx certifications for specific process temperature ranges.

Installation Instructions

General Installation:

  • Unpack and remove any packing material from the lower housing or tee.
  • The switch can be installed in any position, but actuation/deactuation flow rates listed in charts are based on horizontal pipe runs and are nominal values. For precise settings, factory calibration is recommended.

V6 Models with Tee:

  • Supplied in 1/2" - 2" NPT sizes.
  • Install in piping with the arrow pointing in the direction of flow.

V6 Low Flow Models:

  • Feature 1/2" NPT connections and are field adjustable.
  • Install with the arrow pointing in the direction of flow.
  • To adjust, loosen the four socket head cap screws on the bottom. The adjustment valve rotates 90° between "O" (open) and "C" (closed). Refer to flow charts for approximate ranges. Tighten screws once the desired flow rate is set.

V6 with Field Trimmable Vane:

  • Allows installers to select approximate actuation/deactuation points by trimming the vane at letter-designated marks on a removable template.
  • Install in piping with the arrow pointing in the direction of flow.
  • When using bushings, they must be back-drilled to allow proper clearance for unrestricted vane travel. Bore the I.D. to 13/16" (20 mm) for 1/2" x 3/4" bushings or 1" (25 mm) for larger bushings. Ensure the bore depth leaves internal threads 9/16" (14 mm) high for proper engagement. Verify vane travel and switch operation after installation.

Electrical Connections

Connect wire leads in accordance with local electrical codes and the required switch action.

  • Normally Open (N.O.) contacts close, and Normally Closed (N.C.) contacts open when flow increases to the actuation point. They return to their "normal" condition when flow decreases to the deactuation point.
  • Wire identification: Black = Common, Blue = Normally Open, Red = Normally Closed.

Grounding: For units with internal and external bonding terminals, use the internal ground screw to ground the control. The external bonding screw is for supplementary bonding as permitted or required by local code. If an external bonding conductor is required, wrap it at least 180° around the external bonding screw. Some CSA models include a separate green ground wire and require a junction box (not supplied).

Diagram shows details of electrical connection components: screw, clamp, conductor, washer.

Specifications

ParameterDetails
ServiceGases or liquids compatible with wetted materials.
Wetted MaterialsVane: 301 SS; Lower body: Brass or 303 SS; Magnet: Ceramic; Tee: Brass, iron, forged steel, or 304 SS. Low flow models may use Buna-N O-rings (fluoroelastomer optional).
Temperature Limits-4 to 220°F (-20 to 105°C) Standard. MT high temp option: 400°F (205°C) (MT not UL, CSA, ATEX, IECEx or KC). Ambient: -4 to 167°F (-20 to 75°C). Process: -4 to 220°F (-20 to 105°C).
Pressure LimitVaries by model and material (e.g., Brass tee models: 250 psi; Stainless steel tee models: 2000 psi).
Enclosure RatingWeatherproof and explosion-proof. UL/CSA listed for Class I, Groups A, B, C, D; Class II, Groups E, F, G.
CertificationsUL, CSA, ATEX (CE 2813 II 2 G Ex db IIC T6 Gb), IECEx (Ex db IIC T6 Gb), Korean KC. Specific temperature classes (T6, T5, T4) depend on process/ambient conditions.
Switch TypeSPDT snap switch standard; DPDT optional.
Electrical RatingUL models: 5A @125/250 VAC. CSA, ATEX, IECEx models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @ 30 VDC (V). MV option: 0.1A @ 125 VAC. MT option: 5A @125/250 VAC.
Electrical ConnectionsUL models: 18 AWG, 18" (460 mm) leads. ATEX/CSA/IECEx models: Terminal block.
Conduit Connections3/4" male NPT standard; 3/4" female NPT on junction box models. M25 x 1.5 with BSPT option.
Process Connection1/2" male NPT on models without a tee.
Mounting OrientationAny position; flow rates in charts are for horizontal runs.
Set Point AdjustmentStandard models: None. Field trimmable vane or adjustable valve on low-flow models.
Weight2 to 6 lb (0.9 to 2.7 kg) depending on construction.
OptionsCustom calibration, bushings, PVC tee, reinforced vane, DPDT relays, etc.

Note: ATEX, IECEx, and KC units have specific installation requirements regarding cable entry and conduit seals for hazardous area compliance.

Model Chart

The following chart details the model number configuration:

ExampleSeriesConstructionBodySwitch TypeTee Connection SizeTee Type and MaterialOptions
V6 EP -BB -D -1 -B-ATV6EPBB (Brass) / SS (Stainless Steel)D (DPDT) / S (SPDT)1 (1/2" NPT) to 6 (2" NPT), LF (Low Flow), 1E-6E (BSPT sizes)B (Brass) / S (Stainless Steel) / SO (No Tee)AT (ATEX), BUSH (Bushing types), CSA, CV, FTR, GL, ID, IEC, JCTLH, KC, MT, MV, NN, ORFB, ORFS, PT, RV, ST, TBC, VIT
V6EPB-B-D-1-B-ATV6EPBB (Brass) / SS (Stainless Steel)D (DPDT) / S (SPDT)1 (1/2" NPT) to 6 (2" NPT), LF (Low Flow), 1E-6E (BSPT sizes)B (Brass) / S (Stainless Steel) / SO (No Tee)AT (ATEX), BUSH (Bushing types), CSA, CV, FTR, GL, ID, IEC, JCTLH, KC, MT, MV, NN, ORFB, ORFS, PT, RV, ST, TBC, VIT

Attention: Units without the "AT" suffix are not Directive 2014/34/EU (ATEX) compliant and are not intended for use in potentially hazardous atmospheres in the EU.

Flow Rate Charts

Approximate actuation/deactuation flow rates are provided for various conditions and configurations. Values are listed as GPM (upper) / M³/HR (lower) for liquids and SCFM (upper) / NM³/M (lower) for air.

V6 With Tee

Cold Water - Factory Installed Tee
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size1.5 (0.34)1.0 (0.23)2.0 (0.45)1.25 (0.28)3.0 (0.68)1.75 (0.40)4.0 (0.91)3.0 (0.68)6.0 (1.36)5.0 (1.14)10.0 (2.27)8.5 (1.93)
Air - Factory Installed Tee
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size6.5 (0.18)5.0 (0.14)10.0 (0.28)8.0 (0.23)14 (0.40)12 (0.34)21 (0.59)18 (0.51)33 (0.93)30 (0.85)43 (1.19)36 (1.02)

V6 Low Flow, Field Adjustable

Cold Water - Low Flow Models
MinimumMaximum
GPM / M³/HR0.04 (0.009)0.75 (0.17)
Air - Low Flow Models
MinimumMaximum
SCFM / NM³/M0.18 (0.005)2.70 (0.08)

V6 With Field Trimmable Vane

Cold Water - Brass or Cast Iron Reducing Tee
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size9.0 (2.0)8.5 (1.9)9.5 (2.2)9.0 (2.0)10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)
a9.5 (2.2)9.0 (2.0)10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)
b10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)
c11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)
d6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)7.0 (1.6)6.5 (1.5)13.0 (3.0)11.0 (2.5)4.3 (1.0)3.9 (0.9)7.6 (1.7)7.1 (1.6)
e7.0 (1.6)6.5 (1.5)13.0 (3.0)11.0 (2.5)4.3 (1.0)3.9 (0.9)7.6 (1.7)7.1 (1.6)4.9 (1.1)4.4 (1.0)8.0 (1.8)7.3 (1.7)
f4.3 (1.0)3.9 (0.9)7.6 (1.7)7.1 (1.6)4.9 (1.1)4.4 (1.0)8.0 (1.8)7.3 (1.7)5.5 (1.2)5.0 (1.1)9.0 (2.0)8.2 (1.9)
g4.9 (1.1)4.4 (1.0)8.0 (1.8)7.3 (1.7)5.5 (1.2)5.0 (1.1)9.0 (2.0)8.2 (1.9)3.5 (0.8)3.1 (0.7)6.0 (1.4)5.6 (1.3)
h5.5 (1.2)5.0 (1.1)9.0 (2.0)8.2 (1.9)3.5 (0.8)3.1 (0.7)6.0 (1.4)5.6 (1.3)4.0 (0.9)3.5 (0.8)7.0 (1.6)6.6 (1.5)
i3.5 (0.8)3.1 (0.7)6.0 (1.4)5.6 (1.3)4.0 (0.9)3.5 (0.8)7.0 (1.6)6.6 (1.5)4.6 (1.0)4.2 (0.9)8.0 (1.8)7.6 (1.7)
j4.0 (0.9)3.5 (0.8)7.0 (1.6)6.6 (1.5)4.6 (1.0)4.2 (0.9)8.0 (1.8)7.6 (1.7)2.6 (0.6)2.3 (0.5)5.6 (1.3)5.2 (1.2)
k4.6 (1.0)4.2 (0.9)8.0 (1.8)7.6 (1.7)2.6 (0.6)2.3 (0.5)5.6 (1.3)5.2 (1.2)1.6 (0.4)1.3 (0.3)3.5 (0.8)3.1 (0.7)
l2.6 (0.6)2.3 (0.5)5.6 (1.3)5.2 (1.2)1.6 (0.4)1.3 (0.3)3.5 (0.8)3.1 (0.7)2.2 (0.5)1.8 (0.4)4.3 (1.0)3.8 (0.9)
m1.6 (0.4)1.3 (0.3)3.5 (0.8)3.1 (0.7)2.2 (0.5)1.8 (0.4)4.3 (1.0)3.8 (0.9)3.0 (0.7)2.4 (0.5)8.0 (1.8)7.5 (1.7)
n2.2 (0.5)1.8 (0.4)4.3 (1.0)3.8 (0.9)3.0 (0.7)2.4 (0.5)8.0 (1.8)7.5 (1.7)10.0 (0.28)7.0 (0.20)20.0 (0.57)16.0 (0.45)
o3.0 (0.7)2.4 (0.5)8.0 (1.8)7.5 (1.7)10.0 (0.28)7.0 (0.20)20.0 (0.57)16.0 (0.45)12.0 (0.34)9.0 (0.25)--
Air - Brass or Cast Iron Reducing Tee
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size9.0 (2.0)8.5 (1.9)9.5 (2.2)9.0 (2.0)10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)39.0 (1.10)37.0 (1.05)40.0 (1.13)38.0 (1.08)
a9.5 (2.2)9.0 (2.0)10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)40.0 (1.13)38.0 (1.08)42.0 (1.19)40.0 (1.13)
b10.0 (2.3)9.3 (2.1)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)42.0 (1.19)40.0 (1.13)50.0 (1.42)44.0 (1.25)
c11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)11.0 (2.5)10.0 (2.3)50.0 (1.42)44.0 (1.25)27.0 (0.76)25.0 (0.71)
d6.2 (1.4)5.5 (1.2)12.0 (2.7)10.0 (2.3)7.0 (1.6)6.5 (1.5)13.0 (3.0)11.0 (2.5)27.0 (0.76)25.0 (0.71)55.0 (1.56)46.0 (1.30)
e7.0 (1.6)6.5 (1.5)13.0 (3.0)11.0 (2.5)4.3 (1.0)3.9 (0.9)7.6 (1.7)7.1 (1.6)30.0 (0.85)28.0 (0.79)32.0 (0.85)30.0 (0.79)
f4.3 (1.0)3.9 (0.9)7.6 (1.7)7.1 (1.6)4.9 (1.1)4.4 (1.0)8.0 (1.8)7.3 (1.7)20.0 (0.57)18.0 (0.51)32.0 (0.85)30.0 (0.79)
g4.9 (1.1)4.4 (1.0)8.0 (1.8)7.3 (1.7)5.5 (1.2)5.0 (1.1)9.0 (2.0)8.2 (1.9)21.0 (0.59)19.0 (0.54)32.0 (0.91)30.0 (0.85)
h5.5 (1.2)5.0 (1.1)9.0 (2.0)8.2 (1.9)3.5 (0.8)3.1 (0.7)6.0 (1.4)5.6 (1.3)23.0 (0.65)21.0 (0.59)34.0 (0.96)32.0 (0.91)
i3.5 (0.8)3.1 (0.7)6.0 (1.4)5.6 (1.3)4.0 (0.9)3.5 (0.8)7.0 (1.6)6.6 (1.5)16.0 (0.45)15.0 (0.42)24.0 (0.68)22.0 (0.62)
j4.0 (0.9)3.5 (0.8)7.0 (1.6)6.6 (1.5)4.6 (1.0)4.2 (0.9)8.0 (1.8)7.6 (1.7)18.0 (0.51)16.0 (0.45)28.0 (0.79)25.0 (0.71)
k4.6 (1.0)4.2 (0.9)8.0 (1.8)7.6 (1.7)2.6 (0.6)2.3 (0.5)5.6 (1.3)5.2 (1.2)19.0 (0.54)17.0 (0.48)33.0 (0.93)30.0 (0.85)
l2.6 (0.6)2.3 (0.5)5.6 (1.3)5.2 (1.2)1.6 (0.4)1.3 (0.3)3.5 (0.8)3.1 (0.7)13.0 (0.37)12.0 (0.34)22.0 (0.62)20.0 (0.57)
m1.6 (0.4)1.3 (0.3)3.5 (0.8)3.1 (0.7)2.2 (0.5)1.8 (0.4)4.3 (1.0)3.8 (0.9)6.4 (0.18)3.8 (0.11)15.0 (0.42)14.0 (0.40)
n2.2 (0.5)1.8 (0.4)4.3 (1.0)3.8 (0.9)3.0 (0.7)2.4 (0.5)8.0 (1.8)7.5 (1.7)10.0 (0.28)7.0 (0.20)20.0 (0.57)16.0 (0.45)
o3.0 (0.7)2.4 (0.5)8.0 (1.8)7.5 (1.7)12.0 (0.34)9.0 (0.25)------
Cold Water - Stainless or Forged Steel Straight Tee and Bushing
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size5.0 (1.1)4.5 (1.0)8.5 (1.9)7.8 (1.8)5.5 (1.2)5.0 (1.1)9.2 (2.1)8.6 (2.0)6.2 (1.4)5.7 (1.3)9.8 (2.2)9.0 (2.0)
a5.5 (1.2)5.0 (1.1)9.2 (2.1)8.6 (2.0)6.2 (1.4)5.7 (1.3)9.8 (2.2)9.0 (2.0)6.8 (1.5)6.3 (1.4)12.0 (2.7)10.0 (2.3)
b6.2 (1.4)5.7 (1.3)9.8 (2.2)9.0 (2.0)6.8 (1.5)6.3 (1.4)12.0 (2.7)10.0 (2.3)2.8 (0.6)2.4 (0.5)8.5 (1.9)7.8 (1.8)
c6.8 (1.5)6.3 (1.4)12.0 (2.7)10.0 (2.3)2.8 (0.6)2.4 (0.5)8.5 (1.9)7.8 (1.8)3.4 (0.8)3.0 (0.7)10.0 (2.3)9.2 (2.1)
d2.8 (0.6)2.4 (0.5)8.5 (1.9)7.8 (1.8)3.4 (0.8)3.0 (0.7)10.0 (2.3)9.2 (2.1)4.0 (0.9)3.6 (0.8)12.0 (2.7)10.0 (2.3)
e3.4 (0.8)3.0 (0.7)10.0 (2.3)9.2 (2.1)4.0 (0.9)3.6 (0.8)12.0 (2.7)10.0 (2.3)2.0 (0.5)1.5 (0.3)5.0 (1.1)3.6 (1.0)
f4.0 (0.9)3.6 (0.8)12.0 (2.7)10.0 (2.3)2.0 (0.5)1.5 (0.3)5.0 (1.1)3.6 (1.0)2.5 (0.6)2.0 (0.5)6.5 (1.48)6.1 (1.39)
g2.0 (0.5)1.5 (0.3)5.0 (1.1)3.6 (1.0)2.5 (0.6)2.0 (0.5)6.5 (1.48)6.1 (1.39)3.5 (0.8)3.0 (0.7)9.0 (2.0)8.2 (1.9)
h2.5 (0.6)2.0 (0.5)6.5 (1.48)6.1 (1.39)3.5 (0.8)3.0 (0.7)9.0 (2.0)8.2 (1.9)7.0 (1.6)5.5 (1.2)10.0 (2.3)8.0 (1.8)
i3.5 (0.8)3.0 (0.7)9.0 (2.0)8.2 (1.9)7.0 (1.6)5.5 (1.2)10.0 (2.3)8.0 (1.8)10.0 (2.3)8.0 (1.8)--
j7.0 (1.6)5.5 (1.2)10.0 (2.3)8.0 (1.8)10.0 (2.3)8.0 (1.8)------
k10.0 (2.3)8.0 (1.8)----------
Air - Stainless or Forged Steel Straight Tee and Bushing
Vane1/2" NPT3/4" NPT1" NPT1-1/4" NPT1-1/2" NPT2" NPT
Full Size21.0 (0.59)18.0 (0.51)33.0 (0.93)30.0 (0.85)22.0 (0.62)20.0 (0.57)39.0 (1.10)36.0 (1.02)24.0 (0.68)22.0 (0.62)42.0 (1.19)38.0 (1.08)
a22.0 (0.62)20.0 (0.57)39.0 (1.10)36.0 (1.02)24.0 (0.68)22.0 (0.62)42.0 (1.19)38.0 (1.08)28.0 (0.79)26.0 (0.74)51.0 (1.44)46.0 (1.30)
b24.0 (0.68)22.0 (0.62)42.0 (1.19)38.0 (1.08)28.0 (0.79)26.0 (0.74)51.0 (1.44)46.0 (1.30)12.0 (0.34)10.0 (0.28)33.0 (0.93)30.0 (0.85)
c28.0 (0.79)26.0 (0.74)51.0 (1.44)46.0 (1.30)12.0 (0.34)10.0 (0.28)33.0 (0.93)30.0 (0.85)14.0 (0.40)12.0 (0.34)37.0 (1.05)34.0 (0.96)
d12.0 (0.34)10.0 (0.28)33.0 (0.93)30.0 (0.85)14.0 (0.40)12.0 (0.34)37.0 (1.05)34.0 (0.96)16.0 (0.45)14.0 (0.40)43.0 (1.22)40.0 (1.13)
e14.0 (0.40)12.0 (0.34)37.0 (1.05)34.0 (0.96)16.0 (0.45)14.0 (0.40)43.0 (1.22)40.0 (1.13)8.0 (0.23)6.5 (0.18)19.0 (0.54)17.0 (0.48)
f16.0 (0.45)14.0 (0.40)43.0 (1.22)40.0 (1.13)8.0 (0.23)6.5 (0.18)19.0 (0.54)17.0 (0.48)11.0 (0.31)10.0 (0.28)26.0 (0.74)24.0 (0.68)
g8.0 (0.23)6.5 (0.18)19.0 (0.54)17.0 (0.48)11.0 (0.31)10.0 (0.28)26.0 (0.74)24.0 (0.68)14.0 (0.40)13.0 (0.37)32.0 (0.91)30.0 (0.85)
h11.0 (0.31)10.0 (0.28)26.0 (0.74)24.0 (0.68)14.0 (0.40)13.0 (0.37)32.0 (0.91)30.0 (0.85)27.0 (0.76)24.0 (0.68)--
i14.0 (0.40)13.0 (0.37)32.0 (0.91)30.0 (0.85)27.0 (0.76)24.0 (0.68)------
j27.0 (0.76)24.0 (0.68)----------
k39.0 (1.10)36.0 (1.02)----------

Dimensions

Detailed dimensional drawings are provided for various configurations, including low-flow models, models with ATEX/IECEx enclosures, and models with trimmable vanes or tees.

Diagrams show overall dimensions and connection ports (NPT).

A table provides specific dimensions (Dim. A, Dim. B) for different pipe sizes and materials (Brass/Ductile Iron, Forged/Stainless Steel, Malleable Iron).

Illustrations detail the trimmable vane and the terminal connection layouts for SPDT and DPDT switches.

Maintenance

Regular inspection and cleaning of wetted parts are recommended. Ensure the cover remains in place to protect internal components. Disconnect power before opening the unit for maintenance or repair. Repairs should be performed by Dwyer Instruments, Inc.

Safety and Compliance

CAUTION: To prevent ignition of hazardous atmospheres, disconnect the device from the power supply before opening.

The product complies with relevant safety standards for hazardous locations, including ATEX and IECEx directives, ensuring safe operation when installed correctly.

Models: E-22, Series V6 Flotect Flow Switch, E-22 Series V6 Flotect Flow Switch, V6 Flotect Flow Switch, Flotect Flow Switch, Flow Switch, Switch

File Info : application/pdf, 16 Pages, 2.08MB

PDF preview unavailable. Download the PDF instead.

E 22 Multilingual ATEX

References

Adobe PDF Library 15.0 Adobe InDesign 16.3 (Macintosh)

Related Documents

Preview Dwyer V4 Flotect Vane Operated Flow Switch: Specifications, Installation, and Operation Manual
Comprehensive guide to the Dwyer V4 Flotect Vane Operated Flow Switch, covering its specifications, installation procedures, operating instructions, and maintenance. Designed for industrial applications, it protects equipment from flow reduction or loss.
Preview Dwyer Rate-Master® Flowmeters: Specifications, Features, and Ordering Guide
Comprehensive technical specifications, features, and ordering information for Dwyer Instruments' Rate-Master® Series RM polycarbonate flowmeters, suitable for gas and liquid measurement.
Preview Dwyer Series RM Rate-Master Flowmeters: Specifications, Installation, and Operation
Comprehensive guide to Dwyer Series RM Rate-Master Flowmeters, covering specifications, installation procedures, operating instructions, maintenance, and troubleshooting for models RMA, RMB, and RMC.
Preview Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch: Specifications and Installation Guide
Comprehensive specifications, installation, and operating instructions for the Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch, designed for bulk solids level indication in industrial applications.
Preview Dwyer Insite IS/PX/TX Series In-Line Flowmeter: Specifications, Installation, and Operation
Detailed specifications, installation guide, operating instructions, and maintenance information for the Dwyer Instruments Insite IS/PX/TX Series Air/Liquid In-Line Flowmeters, including model variations, switch kit installation, and troubleshooting.
Preview Dwyer Series IEF Insertion Electromagnetic Flow Transmitter - Specifications and Installation Instructions
Detailed specifications and installation guide for the Dwyer Series IEF Insertion Electromagnetic Flow Transmitter, covering features, applications, technical data, model selection, and setup procedures.
Preview Mercoid SBLTX Submersible Level Transducer: Specifications and Installation Instructions
Comprehensive guide to the Mercoid Series SBLTX Submersible Level Transducer by Dwyer Instruments, covering detailed specifications, intrinsic safety approvals (UL, ATEX, IECEx, UKCA), installation procedures, and maintenance information for industrial applications.
Preview Mercoid Series SBLTX Submersible Level Transducer: Specifications, Installation, and Operating Instructions
Comprehensive guide to the Mercoid Series SBLTX Submersible Level Transducer, covering specifications, intrinsic safety approvals (UL, ATEX, IECEx, UKCA), installation procedures, wiring diagrams, and maintenance for reliable liquid level measurement in hazardous locations.