Series SBLTX Submersible Level Transducer Specifications - Installation and Operating Instructions

Bulletin L-37

7-3/16 [182.56] TO 7-7/16 [188.91] 1/2 NPT
Ø1 [Ø25.40]
BREATHER TUBE

SUBMERSIBLE CABLE

The Series SBLTX Submersible Level Transducer is manufactured for years of trouble free service. The transducer consists of a piezoresistive sensing element, encased in a 316 SS housing. Bullet nose design protects diaphragm from damage. Comes equipped with a 270-pound tensile strength, shielded, vented cable. Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank.
Intrinsic Safety Approval Classification The SBLTX is UL listed for use in Hazardous (Classified) Locations. The protection method is by Intrinsic Safety, "ia". It was investigated by UL under UL Standard 913 8th Edition, CAN/CSA C22.2 No. 60079-0:15 and CAN/CSA C22.2 No. 60079-11:14.
Hazardous (Classified) Location Intrinsically Safe For: Class I, Div. 1, Groups A,B,C,D; Class II, Groups E,F,G; Class III Class I Zone 0 AEx ia IIC T4 Ga Zone 20 AEx ia IIIC T135°C Da Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Ta = -20°C to 80°C (ETFE Cable) Ta = -20°C to 65°C (Polyurethane Cable) Install in accordance with Control Drawing 001833-43. See Control Drawing 001833-43 for Entity Parameters.
ATEX Certified for: II 1 G Ex ia IIC T4 Ga / II 1 D Ex ia IIIC T135°C Da (-20°C  Tamb  80°C ETFE cable) (-20°C  Tamb  65°C Polyurethane cable) ATEX EU-Type Certificate: DEMKO 18 ATEX 2080 ATEX Standards: EN IEC 60079-0, EN 60079-11 IECEx Certified for: Ex ia IIC T4 Ga / Ex ia IIIC T135°C Da (-20°C  Tamb  80°C ETFE cable) (-20°C  Tamb  65°C Polyurethane cable) IECEx Certificate of Conformity: IECEx UL 18.0086 IECEx Standards: IEC 60079-0, IEC 60079-11 UKCA Ex Certified for: II 1 G Ex ia IIC T4 Ga / II 1 D Ex ia IIIC T135°C Da (-20°C  Tamb  80°C ETFE cable) (-20°C  Tamb  65°C Polyurethane cable) UKCA Ex Certificate: UL21UKEX2364 UKCA Ex Standards: EN IEC 60079-0, EN 60079-11 Install in accordance with Control Drawing 001833-46. See Control Drawing 001833-46 for Entity Parameters.

SPECIFICATIONS Service: Compatible liquids. Wetted Materials: Body: 316 SS, 316L SS; Bullet nose: PVC; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer. Accuracy: ±0.25% of FS. Temperature Limit: ETFE cable equipped -4 to 176°F (-20 to 80°C); Polyurethane cable equipped -4 to 149°F (-20 to 65°C). Compensated Temperature Range: -4 to 176°F (-20 to 80°C). Thermal Effect: Less than ±0.02% FS/°F. Pressure Limit: 2X FS. Power Requirement: 10-28 VDC. Output Signal: 4-20 mA DC, 2-wire. Response Time: 50 ms. Max. Loop Resistance: 900 . Electrical Connections: Wire pigtail. Mounting Orientation: Suspended in tank below level being measured. Weight: 2.2 lb (1.0 kg). Compliance: CE, UKCA, See Intrinsic Safety Approval Classification. Note: References to ATEX apply to UKCA Ex.
WARNING Use with approved safety barriers using entity evaluation.

DWYER INSTRUMENTS, LLC
P.O. BOX 373 · MICHIGAN CITY, INDIANA 46360, U.S.A.

Phone: 219-879-8000 Fax: 219-872-9057

www.dwyer-inst.com e-mail: info@dwyermail.com

CAUTION Do not exceed specified supply voltage ratings. Permanent damage not covered by warranty will result. This device is not
designed for 120 or 240 VAC operation. Use only on 10-28 VDC.
INSTALLATION 1. Location: Select a location where the temperature of the transducer will be
between -4 and 176°F (-20 to 80°C) for ETFE cable or -4 and 149°F (-20 to 65°C) for polyurethane cable. Distance from the receiver is limited only by total loop resistance.

MAINTENANCE After final installation of the pressure transducer and its companion receiver, no routine maintenance is required. A periodic check of system calibration is suggested. The
Series SBLTX transducer are not field repairable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact
customer service to receive a return goods authorization number before shipping.

2. Position: The transducer is not position sensitive. However all standard models are originally calibrated with the unit in a position with the pressure connection downward. Although they can be used at other angles, for best accuracy it is recommended that units be installed in the position calibrated at the factory.
3. Mounting: The transducer can be mounted via several methods. It can be suspended from the electrical cable, it can be placed resting on the bottom of the tank in either horizontal or vertical orientation, or it can be attached to a pipe or hang wire by the 1/2 NPT male connection on the top of the housing.
4. Electrical Connections Wire Length: The maximum length of wire connecting the transducer and receiver is a function of wire size and receiver resistance. Wiring should not contribute more than 10% of the receiver resistance to total loop resistance. For extremely long runs (over 1000 feet), choose receivers with higher resistance to minimize the size and cost of connecting leads. Where wiring length is under 100 feet, wire as small as 22 AWG can be used.

5. Wiring: An external power supply delivering 10-28 VDC with minimum current capability of 40 mA DC (per transducer) is required to power the control loop. See Figure A for connection of the power supply, transducer and receiver. The range of appropriate receiver load resistance (RL) for the DC power supply voltage available is expressed by the formula:

RL Max = Vps ­ 10 V 20 mA DC

Shielded cable is recommended for control loop wiring.

PRESSURE TRANSDUCER

RED BLACK

mA RECEIVER -

POWER SUPPLY 10-28 VDC

Figure A

Black wire is negative [-] and red wire is positive [+].

BLACK [-]

Figure B

RED [+]

""

""

""

 

""

""

""

©Copyright 2022 Dwyer Instruments, LLC

Printed in U.S.A. 5/22

DWYER INSTRUMENTS, LLC
P.O. BOX 373 · MICHIGAN CITY, INDIANA 46360, U.S.A.

Phone: 219-879-8000 Fax: 219-872-9057

 

FR# 443550-00 Rev. 10
www.dwyer-inst.com e-mail: info@dwyermail.com



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Macintosh)

Related Documents

Preview Mercoid SBLTX Submersible Level Transducer: Specifications and Installation Instructions
Comprehensive guide to the Mercoid Series SBLTX Submersible Level Transducer by Dwyer Instruments, covering detailed specifications, intrinsic safety approvals (UL, ATEX, IECEx, UKCA), installation procedures, and maintenance information for industrial applications.
Preview Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch: Specifications and Installation Guide
Comprehensive specifications, installation, and operating instructions for the Dwyer Series P/G Explosion Proof Ultra Mag™ Level Switch, designed for bulk solids level indication in industrial applications.
Preview Dwyer V4 Flotect Vane Operated Flow Switch: Specifications, Installation, and Operation Manual
Comprehensive guide to the Dwyer V4 Flotect Vane Operated Flow Switch, covering its specifications, installation procedures, operating instructions, and maintenance. Designed for industrial applications, it protects equipment from flow reduction or loss.
Preview Dwyer Series V6 Flotect Flow Switch: Specifications, Installation, and Operation
Comprehensive guide to the Dwyer Series V6 Flotect Flow Switch, covering specifications, installation instructions, electrical connections, and performance data for various configurations and applications.
Preview Dwyer Series DM-2000 Differential Pressure Transmitter - Technical Data
Explore the Dwyer Series DM-2000 Differential Pressure Transmitter, a digital device for measuring air and compatible gases. Features include easy calibration, tamper-proof settings, quick response, and a clear LCD display. This transmitter is designed for seamless integration into Building Automation Systems and offers a standard 4-20 mA output.
Preview Dwyer Insite IS/PX/TX Series In-Line Flowmeter: Specifications, Installation, and Operation
Detailed specifications, installation guide, operating instructions, and maintenance information for the Dwyer Instruments Insite IS/PX/TX Series Air/Liquid In-Line Flowmeters, including model variations, switch kit installation, and troubleshooting.
Preview Dwyer A-610 Pipe Mounting Kit Installation Instructions
Detailed installation instructions for the Dwyer A-610 Pipe Mounting Kit, compatible with Magnehelic, Capsuhelic gages, and 1950 series switches. Includes hole selection guide and mounting procedures.
Preview Dwyer CCT60/70 Series True RMS Current Transformers - Solid/Split Core
Dwyer Instruments CCT60/70 series True RMS Current Transformers offer field-selectable ranges in solid or split core configurations, ideal for BAS and HVAC applications. Features include integral mounting flange and jumper selectable ranges.