SBP SNLXMTSOC Invicta Touch Interface
Overview
- Invicta Interface is a specialized indicating instrument designed for use with Invicta Xero batteries.
- Based on RS485 communication, it provides detailed information on battery status, including voltage, current, remaining capacity, temperature, and configuration settings.
- Unlike traditional setups that require a connection to the diverter, Invicta Interface can be directly linked to the battery using a simple wiring harness.
This streamlined connection method not only reduces the cost of the wiring harness but also significantly speeds up the installation process.
Attention
- Before using this product, please read this manual thoroughly.
- Retain this manual for future reference.
- Ensure correct usage by carefully following the instructions provided in this manual. The company is not liable for any direct, indirect, or consequential damages resulting from improper use or misuse of this product or related items.
- Information in this manual is subject to change without prior notice.
- Avoid using input voltages or currents that exceed the specified limits to prevent product damage or fire.
- Professional technicians should handle installation and wiring. If you encounter any issues, please contact the company’s technical support promptly.
Specifications
- Rated Input Voltage 9-60V
- Rated Power <5W
- Operating Current Maximum 170mA (VCC=12V)
- Operating Current Minimum 55mA (VCC=12V)
- Resolution 800×480
- Operating Humidity 10%-90%RH
- Protective Level IP65 (Front)
- Communication RS485
- Operating Temperature -20~70oC
- Storage Temperature -30~80oC
- Net Weight 340g
- Type LCD
- Screen Size 5 Inch
- External Dimension 118Lx160Wx6.6D
- Internal Dimensions 106Lx148Wx16.9D
- Compatible Batteries SNLX (Invicta Xero)
Dimension
Features
- Wired touchscreen interface for Invicta Xero batteries (SNLX)
- CAN/RS485/RS232 communication
- IP65 water and dust-resistant front with rubber gasket separator
- Directly connectable to Invicta Xero batteries or via the Invicta I-Hub.
- Features a 5.0-inch IPS LCD screen with 800×480 pixel resolution and 262K true-color display.
- Equipped with a high-reliability capacitive touch panel.
- Includes a built-in speaker, LED lamp, and photosensitive sensor.
- Housed in a protective shell with anti-UV properties and conformal coating.
- Emits an audible alarm when specified alarm, protection, or low SOC conditions are detected.
Battery Setup
- Step 1: Initial Setup
- Connect Power Cable: Ensure the Invicta Interface power cable is correctly connected to the Invicta Xero, observing polarity.
- Connect Communication Cable: Connect the communication cable to the LINK IN port of the Invicta Xero or the Invicta Interface port of the INVICTA I-HUB (if applicable).
- Verify that the INVICTA I-HUB power and communication cables are properly connected to the Invicta Xero.
- Step 2: Networking Multiple Batteries
- Connect Communication Lines: Connect the LINK OUT of the first battery to the LINK IN of the second, and so on for additional batteries.
- Connected State: Turn on all batteries then press and hold the RESET button on the first Invicta Xero display for over 3 seconds. All SOC indicator lights should flash simultaneously. If not, try again.
- Communication State: Press and hold the RESET button on the first battery for over 20 seconds. All SOC indicator lights will race alternately. This process may take 2-3 minutes.
- Once complete, the lights will stop flashing and display the battery SOC. If unsuccessful, try again.
- Configure Bluetooth App: Use the Invicta Legion Bluetooth app to set the system name, voltage platform, and number of series and parallel connections. Select the first battery as the main battery.
- Step 3: Single Battery Setup
- Connected State: Follow the same procedure as in Step 2 to enter the connected state.
- Communication State: Follow the same procedure as in Step 2 to enter the communication network state.
Download The Invicta Legion APP For Free
Installation
Housing Requirements
- The rubber gasket will be black. Ensure nothing is obstructing the seal as this is a protection for the internals of the device.
- Minimum opening requirement (mm) 107H x 149W x 18.5D
- The maximum requirement should not exceed the external dimensions of the unit
- Install the unit from the front of the housing opening
Screw Adjustment
- Loosen the screw 90o in an anti-clockwise direction, the clip will be in a horizontal position
- Rotate clip 90O in a clockwise direction until in a vertical position
- Lock the 4 screws to fix the product on the housing
Screen Display
Parameter Page
- SOC: The state of charge, is displayed as a percentage. When the SOC is not greater than 10%, the interface will change from green to yellow.
- Voltage (V): The overall voltage of the battery system.
- Current (A): The current being passed through the battery system.
- Remaining Capacity (Ah): The overall remaining capacity of the battery system.
- Max Temp: The maximum temperature of the battery system.
- Min Temp: The minimum temperature of the battery system.
- It is possible to select temperature units, including Celsius and Fahrenheit in the setting interface.
- Configuration: The number of series and parallel connections in battery systems.
Detail Page
- Voltage (V): The voltage of the chosen pack.
- Current (A): The current being passed through the chosen pack.
- Capacity (Ah): The remaining capacity of the chosen pack.
- Temp: The temperature of the chosen pack. It is possible to select temperature units, including Celsius and Fahrenheit.
- Power (W): The power is transferred through the chosen pack.
- Cycles: The number of cycles.
Setting Page
- Time Setting: Invicta Touch Interface has RTC, including year, month, day, hour, minute, and second. It is possible to modify the time through the setting interface. It must click confirm after completing the time setting.
- Language Selection: Invicta Interface can select languages, including English and Chinese.
- Temperature Unit: Invicta Interface can select temperature units, including Celsius and Fahrenheit.
Warning Protection Alarms
Warning Alarms
Cell under voltage warning | Cell over voltage warning | Battery under voltage warning |
Battery over voltage warning | Charge over current warning | Discharge over current warning |
Low ambient temperature warning | High ambient temperature warning | Mos low-temperature warning |
Most high-temperature warning | Cell charge low temperature warning | Cell charge high-temperature warning |
Cell discharge low temperature warning | Cell discharge high-temperature warning | Low capacity warning |
Low insulating resistance warning | Cell disconnected warning | Cell failure warning |
Cell heating abnormal warning | Cell/system over voltage warning | Cell/system under voltage warning |
Discharge high-temperature warning | Discharge low-temperature warning | Charge high-temperature warning |
Charge low temperature warning | Discharge over current warning | Charge over current warning |
Internal-net communication failure warning | Cells unbalance warning |
Protection Alarms
Cell under voltage protection | Cell over-voltage protection | Battery under voltage protection |
Battery over-voltage protection | Secondary charge over current protection | Secondary discharge over current protection |
Short circuit protection | Cell failure protection | Charge over current protection |
Discharge over current protection | Low ambient temperature pro- tection | High ambient temperature pro- tection |
Mos low temperature protection | Most high-temperature protection | Cell charge low temperature protection |
Cell charge high-temperature protection | Cell discharge low temperature protection | Cell discharge high-temperature protection |
Low capacity protection | Low-insulating resistance protection | Cell disconnected protection |
Mos failure protection | AFE failure protection | Cells voltage difference protection |
Cell/system over-voltage protection | Cell/system under voltage pro- tection | Discharge high-temperature protection |
Discharge low temperature pro- tection | Charge high-temperature protection | Charge low temperature protection |
Discharge over current protection | Charge over current protection | Mos failure protection |
System failure protection | Cells unbalance protection |
- SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne
- Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National
- Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207
- T 1300 001 772
- E info@spb.net.au
- W spb.net.au
Documents / Resources
![]() |
SBP SNLXMTSOC Invicta Touch Interface [pdf] Instruction Manual SNLXMTSOC Invicta Touch Interface, SNLXMTSOC, Invicta Touch Interface, Touch Interface, Interface |