Salto Logo

SALTO Wall Reader Keypad Entry System

SALTO Wall Reader Keypad Entry System

Card Reader Installation Guide

Card Reader Installation Guide 01

 

Card Reader Installation Guide 02

 

Card Reader Installation Guide 03

Installation

Installation 01

 

Installation 02

 

Installation 03

GANG ELECTRICAL STANDARD BOX

Installation 04

Maintenance

Dampen a lint-free cloth or cotton swap with alcohol. Gently rub the cloth back and forth across the sensor. Repeat the process once or twice as needed. Visually observe that no residual solution remains on the sensor, especially the edges.
Caution: Harsh and abrasive materials are not recommended for cleaning sensors.

Maintenance 01

Electrical Characteristics

Operation Conditions
Temperature WRD0B – WRD0S – WRD0BK

-35~66°C

Temperature WRD0J –  WRD0GK – WRD0JK

-25~66°C

Temperature WRD0BF – WRD0JF

-20~66°C

Humidity

35~85%

Installation Example

Installation Example 01

Installation Example with RJ45

Installation Example 02

Minimum distance between readers 20in (50cm).

Signal

Light Time Buzzer

Time

Card / finger rejection

Red

1 sec

High pitched 50/50

1sec 3sec

Privacy or emergency status

Red 5x(50/50×3 + off 300)

3 sec

High pitched 5x(50/50×3 +off 300)

0,3sec

Standard opening

Green

1 sec

Low pitched

0,2sec

Standard locking

Red

0,5 sec

Low pitched

2,4sec

Open plus office

Green 400/200

2,4 sec

High pitched/Low pitched 400/200

Cont.

CLR Button

Orange

Cont.

High pitched

450msc

Reset

Orange 50/100

450msc

Low pitched 50/100

Cont.  100

Waiting for card / finger

Blinking green 500/500

Cont.

Low pitched 500/500

msec

Card / finger processing

Blinking yellow 50/50

100msc

Low pitched 50/50

1 sec

Successfully processed card / finger

Green

1 sec

Low pitched

UL Statements

Tested by UL with Mifare (DESFIRE, ULTRALIGHT C) and HID iCLASS RFID communication, and with Mobile APP (JustIN Movile version 2.x) through Bluetooth version 4.2. Minimum Operating System version for Android: 4.3 or later and for iOS: 10.0 or later. A means of verification shall be employed by the user to enable access to the wireless electronic device such as a PIN or biometric feature. The wireless electronic device is not capable of command, control, programming, or any other system manipulation and it is only to be used in the same manner as a physical credential. Wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70 or CSA C22.1-02 – Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations

UL294 Performance Level

FEATURE

LEVEL

Destructive attack

I

Line Security

I

Endurance

IV

Standby power

Per rating of the power supply

Comply with ULC-S319 Class I

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Documents / Resources

SALTO Wall Reader Keypad Entry System [pdf] Installation Guide
WRDX0A4, Wall Reader Keypad Entry System, Wall Reader, Wall Reader Keypad

References

Leave a comment

Your email address will not be published. Required fields are marked *