SALTO IQ303 Gateway Device System
Specifications
- Device Type: Gateway
- Communication: Nebula to SALTO BLUEnet
- Features: SVN (SALTO Virtual Network)
- Interfaces: Ethernet, WIFI (*), Bluetooth, RS-485
- Weight: 225g
- Dimensions: 122.5mm (4-13/16″)
Product Usage Instructions
- The IQ3 device can be installed on the ceiling or wall with hidden cable connections. Follow the provided wiring diagram for proper installation.
- For desktop installation, refer to the wiring diagram provided. Ensure the device is securely placed on the desktop for stable operation.
- Depending on the model, connect the device using Ethernet, WIFI, or Ethernet + POE. Use the provided wiring diagram for proper communication setup.
- For RS-485 communication, ensure the bus termination resistor is correctly set based on the node’s position in the bus. Use a tool, like pliers, for jumper manipulation as needed.
- For power supply (except PoE), refer to the external power supply characteristics provided in the manual for proper voltage and current requirements.
FAQ
- Q: What are the available interfaces on the IQ3 device?
- A: The IQ3 device is equipped with Ethernet, WIFI (*), Bluetooth, and RS-485 interfaces depending on the model.
- Q: How should I configure the RS-485 communication on the IQ3 device?
- A: Follow the wiring diagram provided and ensure the bus termination resistor is set correctly based on the node’s position in the bus. Use a tool for jumper manipulation if needed.
- Q: What are the installation options for the IQ3 device?
- A: The IQ3 device can be installed on the ceiling, wall with hidden cable connections, or on a desktop following the provided instructions and wiring diagrams.
Installation guide
- The IQ3 is a Gateway device that ensures the communication between Nebula and the SALTO BLUEnet devices providing the SVN (SALTO Virtual Network) features.
- It is equipped with an Ethernet, WIFI (*), Bluetooth, and RS-485 interface.
- (*) Depending on the model.
Dimension
EUROPE EUROPA
NORTH AMERICA
SWISS
Installation
CEILING/WALL INSTALLATION WITH HIDDEN CABLE
CEILING/WALL INSTALLATION WITH EXPOSED CABLE
DESKTOP INSTALLATION
Wiring
ETHERNET MODEL
ETHERNET + POE MODEL
ETHERNET + WIFI MODEL
ETHERNET MODEL
ETHERNET + POE MODEL
- If there is no PoE infrastructure, use an auxiliary power supply
ETHERNET + WIFI MODEL
- If you do not connect to a WIFI network, connect the Ethernet cable.
COMMUNICATION WIRING DIAGRAM IN IQ3/SALTO Node
- RS485 CONNECTION TO TERMINAL
RS485 CONNECTION WITH CABLE JACK
- Power (except PoE).
- Ethernet.
- RS485 (Jack cable).
- RS485.
Electrical Features
EXTERNAL POWER SUPPLY CHARACTERISTICS | |||
Min | Max | Typ | |
Input Voltage | 12-5%V | 12+5%V | 12V |
Max Input Power | 15w | ||
Current Consumption* | 200mA | 60mA |
- Excluding RS485 Nodes.
- Power supply must be calculated taking into account SALTO Nodes’ current consumption.
CABLE REQUIREMENTS | |
Ethernet UTP CAT5e | |
Node Connection | Employing Terminal Blocks: Generic twisted pair |
Through RJ45: UTPCAT5e |
OPERATING CONDITIONS | ||
Min | Max | |
Temperature | 0ºC | 60ºC |
Humidity | 0 | 95% (Non condensing) |
SALTO BLUEnet CHARACTERISTICS | |
Frequency Range | 2400 MHz to 2483.5 MHz |
Standard | Bluetooth 5.2 Compliant |
TX power | 8dBm |
Indoor Range | 10 – 15m * |
WIFI CHARACTERISTICS | |
Frequency Range | 2400 MHz to 2483.5 MHz |
Standard | IEEE 802.11b/g/n compliant |
TX power | 16dBm |
Range | 25 – 30m * |
- Depending upon the installed environment.
- To ensure correct operation, do not install the device near a metallic surface.
MAX. NUMBER OF DEVICES TO BE CONNECTED |
SALTO Nodes 6 |
Access points 112 |
PoE |
PoE Norms: IEEE 802.3af / IEEE 802.3at |
PoE Class 0 |
- The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls…)
- The receiver device must be located facing the product antenna. Please check your product’s BLUEnet antenna position.
- Recommended connectivity distance: 10m – 15m
Configuration
- The device is configured using the Nebula App.
- Ethernet test: without any type of setup, the IQ3 is a DHCP-ready device. If your network supports it, it is possible to check the Ethernet connectivity by pinging the address SALTO-IQ3-XXXXXX(XXXXXX corresponds to the final 6 digits of MAC).
Installation example
- Maximum number of SALTO Nodes: 6
- Maximum number of access points: 112
Signals
Operational test
- Check that the red light turns on.
- If you have connected to Ethernet, check that the lights on the RJ45 turn on.
All contents were current at the time of publication.
SALTO Systems S.L. reserves the right to change the availability of any item in this catalog, its design, construction, and/or materials.
Documents / Resources
![]() |
SALTO IQ303 Gateway Device System [pdf] Installation Guide IQ303 Gateway Device System, IQ303, Gateway Device System, Device System, System |