IMPORTANT: The Ethernet connection requires the use of the provided power supply adapter for a correct product operation

Select desired communication mode, USB (a) or Ethernet (b)
Installation
Installation

DESKTOP READER MODE
Only with USB communication
To be able to work in Desktop Reader mode, the NCoder must be configured through the Space software
 Connection

Electrical characteristics

OPERATING CHARACTERISTICS
Min Max Unit
Temperature 0 50 °C
Humidity 0 95 %
RF CHARACTERISTICS
Min Cen Max Unit
RFID frecuency 13.56 Mhz
Bluetooth Smart frecuency 2400c 2445 2483.5 Mhz
POWER CONSUMPTION
Typ. Max. Unidad
USB 250 400 mA
Ethernet 350 500 mA
CABLE REQUIREMENTS
Ethernet UTP CAT5e
USB USB 2.0 Male USB A to Male USB B

Configuration

  • The NCoder is a DHCP ready device.
  • It is possible to manually change the IP settings from dynamic to static using a web browser.
  • Connect the NCoder to the PC using an Ethernet cable (not provided).
  • Make sure that the NCoder (v2) has been declared in “SALTO Network” and that the “Online” option is selected in the NCoder options (Admin/local settings).
  • Press the back clear button for 5s to access the addressing mode (see addressing status signaling).
  • Access the 192.168.0.234 IP internal IP address using a web browser.
  • Change the needed parameters and use the “send” option. The NCoder will leave the addressing mode automatically (if no actions are required you can
    leave the addresing mode by pressing the CLR button for 5s).
  • Click on the back clear button and press “INITIALIZE” (SALTO Network/NCoder).
  • The NCoder is now ready to be used.
    Configuration

USB CONNECTION

  • Connect the NCoder to the PC using the provided USB cable.
  • Make sure that “local” option is selected in the NCoder options (Admin/local settings).
  • Perform any operation against the NCoder (ex. “Read Key”).
  • You will get the following warning message
    Configuration

DIPSWITCH SET UP

For future uses
Power On Off

INITIALIZATION ON SPACE

It is necessary that NCoder be in factory mode (factory mode signalling). Press CLR button during 5 seconds and continue the steps described at Space’s user manual.

FATORY RESET

If it is necessary to re-install the NCoder, it is possible to restart it to factory mode. If you connect power supply while pressing CLR button during 5 seconds, the NCoder will return to the same status as when it left the factory.

Maintenance

Dampen a lint-free cloth or cotton swap with alcohol. Gently rub the cloth back and forth across the sensor. Repeat the process once or twice as needed. Visually observe that no residual solution remains on the sensor, especially the edges.
Caution: Harsh and abrasive materials are not recommended for cleaning sensors. Keep the device in a safe place!
Cleaning Instruction
Cleaning Instruction

Signalling

SIGNALLING LIGHT TIME BUZZER TIME
Waiting for key/finger Blinking green 500/500 Cont. Low pitched 500/500 Cont.
Key processing Blinking yellow 50/50 100 msec Low pitched 50/50 100 msec
Successfully processed key/finger Green 1 sec Low pitched 1 sec
Operation failure Red 1 sec High pitched 50/50 1 sec
Factory mode Red Cont. No
Addressing status Yellow Cont No
Waiting for initialization Blinking red 500/500 Cont. No
Ncoder start up Green 1 sec No
DR activation Yellow 1000 + Green 500 1,5 sec Silence 1000 + high pitched 500 1,5 sec
Finger successfully reading Blinking green 50/50 300 msec Low pitched 50/50 300 msec
Finger failure reading Blinking red 100/100 200 msec No

All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials. © 2021 SALTO Systems S.L.

Documents / Resources

SALTO ECxx....F series NCoder USB Ethernet Connection [pdf] User Guide
ECxx....F series NCoder USB Ethernet Connection, ECxx....F series, NCoder USB Ethernet Connection, USB Ethernet Connection, Ethernet Connection, Connection

References

Leave a comment

Your email address will not be published. Required fields are marked *